Preclinical evaluation of the versius surgical system, a new robot-assisted surgical device for use in minimal access general and colorectal procedures

被引:45
|
作者
Morton, Jonathan [1 ]
Hardwick, Richard H. [1 ]
Tilney, Henry S. [2 ]
Gudgeon, A. Mark [2 ]
Jah, Asif [3 ]
Stevens, Lewis [4 ]
Marecik, Slawomir [5 ,6 ]
Slack, Mark [7 ]
机构
[1] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Dept Gastrointestinal Surg, Cambridge, England
[2] Frimley Hlth NHS Fdn Trust, Dept Surg, Frimley Pk Hosp, Surrey, England
[3] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Cambridge HepatoPancreato Biliary & Transplant Ct, Cambridge, England
[4] Queen Mary Univ London, Barts Canc Inst, Dept Mol Oncol, London, England
[5] Advocate Lutheran Gen Hosp, Div Colon & Rectal Surg, Chicago, IL USA
[6] Univ Illinois, Chicago, IL 60680 USA
[7] CMR Surg Ltd, 1 Evolut Business Pk,Milton Rd, Cambridge CB24 9NG, England
关键词
Minimally invasive surgical procedures; Robotic surgical procedures; General surgery; Colorectal surgery; SURGERY;
D O I
10.1007/s00464-020-07622-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective To evaluate the utility of a new robot-assisted surgical system (the Versius Surgical System, CMR Surgical, Cambridge, UK) for use in minimal access general and colorectal surgery, in a preclinical setting. Summary background data Robot-assisted laparoscopy has been developed to overcome some of the important limitations of conventional laparoscopy. The new system is designed to assist surgeons in performing minimal access surgery and overcome some of the challenges associated with currently available surgical robots. Methods Cadaveric sessions were conducted to evaluate the ability of the system to provide adequate surgical access and reach required to complete a range of general and colorectal procedures. Port and bedside unit positions were recorded, and surgical access and reach were evaluated by the lead surgeon using a visual analogue scale. A live animal (porcine) model was used to assess the surgical device's safety in performing cholecystectomy or small bowel enterotomy. Results Nine types of procedure were performed in cadavers by nine lead surgeons; 35/38 procedures were completed successfully. The positioning of ports and bedside units reflected the lead surgeons' preferred laparoscopic set-up and enabled good surgical access and reach. Cholecystectomy (n = 6) and small bowel enterotomy (n = 5) procedures performed in pigs were all completed successfully by two surgeons. There were no device-related intra-operative complications. Conclusions This preclinical study of a new robot-assisted surgical system for minimal access general and colorectal surgery demonstrated the safety and effectiveness of the system in cadaver and porcine models. Further studies are required to assess its clinical utility.
引用
收藏
页码:2169 / 2177
页数:9
相关论文
共 50 条
  • [1] Preclinical evaluation of the versius surgical system, a new robot-assisted surgical device for use in minimal access general and colorectal procedures
    Jonathan Morton
    Richard H. Hardwick
    Henry S. Tilney
    A. Mark Gudgeon
    Asif Jah
    Lewis Stevens
    Slawomir Marecik
    Mark Slack
    Surgical Endoscopy, 2021, 35 : 2169 - 2177
  • [2] Preclinical Evaluation of the Versius Surgical System, a New Robot-assisted Surgical Device for Use in Minimal Access Renal and Prostate Surgery
    Thomas, Benjamin C.
    Slack, Mark
    Hussain, Muddassar
    Barber, Neil
    Pradhan, Ashish
    Dinneen, Eoin
    Stewart, Grant D.
    EUROPEAN UROLOGY FOCUS, 2021, 7 (02): : 444 - 452
  • [3] Usability assessment of Versius, a new robot-assisted surgical device for use in minimal access surgery
    Haig, Fiona
    Medeiros, Ana Cristina Barbosa
    Chitty, Karen
    Slack, Mark
    BMJ SURGERY INTERVENTIONS & HEALTH TECHNOLOGIES, 2020, 2 (01)
  • [4] Preclinical evaluation of a new robot-assisted surgical system for use in gynecology minimal access surgery
    Carey, Marcus
    Bali, Anish
    Pandeva, Ivilina
    Pradhan, Ashish
    Slack, Mark
    GYNECOLOGICAL SURGERY, 2020, 17 (01)
  • [5] Preclinical evaluation of the Versius surgical system: A next-generation surgical robot for use in minimal access prostate surgery
    Vasdev, Nikhil
    Charlesworth, Philip
    Slack, Mark
    Adshead, Jim
    BJUI COMPASS, 2023, 4 (04): : 482 - 490
  • [6] Using end-user feedback to optimize the design of the Versius Surgical System, a new robot-assisted device for use in minimal access surgery
    Hares, Luke
    Roberts, Paul
    Marshall, Keith
    Slack, Mark
    BMJ SURGERY INTERVENTIONS & HEALTH TECHNOLOGIES, 2019, 1 (01)
  • [7] Interim safety analysis of the first-in-human clinical trial of the Versius surgical system, a new robot-assisted device for use in minimal access surgery
    Dhananjay Kelkar
    Mahindra A. Borse
    Girish P. Godbole
    Utkrant Kurlekar
    Mark Slack
    Surgical Endoscopy, 2021, 35 : 5193 - 5202
  • [8] Interim safety analysis of the first-in-human clinical trial of the Versius surgical system, a new robot-assisted device for use in minimal access surgery
    Kelkar, Dhananjay
    Borse, Mahindra A.
    Godbole, Girish P.
    Kurlekar, Utkrant
    Slack, Mark
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2021, 35 (09): : 5193 - 5202
  • [9] Preclinical evaluation of Versius, an innovative device for use in robot-assisted thoracic surgery
    Aresu, Giuseppe
    Dunning, Joel
    Routledge, Tom
    Bagan, Patrick
    Slack, Mark
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 62 (03)
  • [10] Hinotori Surgical Robot System, a novel robot-assisted surgical platform: Preclinical and clinical evaluation
    Hinata, Nobuyuki
    Yamaguchi, Raizo
    Kusuhara, Yoshito
    Kanayama, Hiroomi
    Kohjimoto, Yasuo
    Hara, Isao
    Fujisawa, Masato
    INTERNATIONAL JOURNAL OF UROLOGY, 2022, 29 (10) : 1213 - 1220