An amperometric inhibitor biosensor for the determination of reduced glutathione (GSH) without any derivatization in some plants

被引:23
|
作者
Sezgintürk, MK [1 ]
Dinçkaya, E [1 ]
机构
[1] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Izmir, Turkey
来源
BIOSENSORS & BIOELECTRONICS | 2004年 / 19卷 / 08期
关键词
ascorbate oxidase; glutathione determination; GSH; GSSG; inhibitor biosensors;
D O I
10.1016/j.bios.2003.08.012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study, an amperometric biosensor based on cucumber tissue homogenate was developed for the determination of glutathione. Cucumber (Cucumis sativus L.) tissue homogenate was used as the biological material. The cucumber tissue homogenate was cross-linked with gelatine using glutaraldehyde and fixed on a pretreated teflon membrane. The principle of the measurements was based on the determination of the decrease in the differentiation of oxygen level which had been caused by the inhibition of ascorbate oxidase in the biological material by glutathione. Determinations were carried out by standard curves which were obtained by the measurement of the decrease in the consumed oxygen level related to glutathione concentration. Optimization and characterization studies of the biosensor were carried out and a linearity in the gamma-L-glutamyl-L-cysteinyl-glycine (GSH) concentration range 0.1-2 muM was obtained when 600 muM ascorbic acid was used as a substrate. The repeatability experiments (n = 7) revealed that for 1.5 muM GSH, the average value ((x) over bar), standard deviation (S.D.) and variation coefficient (C.V.) were 1.517 muM, 4.72 x 10(-5), 3.11%, respectively. The biosensor useful lifetime was at least 2 months. The results of some plant samples analyzed with the presented biosensor agreed well with the spectrophotometric method (Ellman's reagent) used as a reference. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:835 / 841
页数:7
相关论文
共 34 条
  • [21] Amperometric determination of reduced glutathione with a new Co-based metal-organic coordination polymer modified electrode
    Yuan, Baiqing
    Zhang, Renchun
    Jiao, Xixi
    Li, Juan
    Shi, Huaizhong
    Zhang, Daojun
    ELECTROCHEMISTRY COMMUNICATIONS, 2014, 40 : 92 - 95
  • [22] DETERMINATION OF REDUCED GLUTATHIONE IN PLANTS AND BIOLOGICAL SAMPLES BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    UENO, S
    ISHIZAKI, M
    JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1994, 40 (01): : 96 - 100
  • [23] Highly sensitive amperometric biosensor based on electrochemically-reduced graphene oxide-chitosan/hemoglobin nanocomposite for nitromethane determination
    Wen, Yunping
    Wen, Wei
    Zhang, Xiuhua
    Wang, Shengfu
    BIOSENSORS & BIOELECTRONICS, 2016, 79 : 894 - 900
  • [24] A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine
    Khalikova, Maria A.
    Satinsky, Dalibor
    Solich, Petr
    Zinchenko, Alexandr A.
    Zhilyakova, Elena T.
    Novikov, Oleg O.
    ANALYTICAL METHODS, 2014, 6 (05) : 1475 - 1481
  • [25] Determination of oxidized and reduced glutathione, by capillary zone electrophoresis, in Brassica juncea plants treated with copper and cadmium
    Mendoza, J
    Soto, P
    Ahumada, I
    Garrido, T
    ELECTROPHORESIS, 2004, 25 (06) : 890 - 896
  • [26] Capillary zone electrophoresis with end-column amperometric detection for the determination of glutathione at a gold/mercury amalgam microelectrode without deoxygenation
    Jin, WR
    Wang, Y
    ANALYTICA CHIMICA ACTA, 1997, 343 (03) : 231 - 239
  • [27] A tryptophan-2-monooxygenase based amperometric biosensor for L- tryptophan determination: Use of a competitive inhibitor as a tool for selectivity increase
    Simonian, A.L.
    Rainina, E.I.
    Fitzpatrick, P.F.
    Wild, J.R.
    Biosensors and Bioelectronics, 1997, 12 (05): : 363 - 371
  • [28] A tryptophan-2-monooxygenase based amperometric biosensor for L-tryptophan determination: Use of a competitive inhibitor as a tool for selectivity increase
    Simonian, AL
    Rainina, EI
    Fitzpatrick, PF
    Wild, JR
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (05): : 363 - 371
  • [29] Evidence that reduced glutathione (GSH) is a potent inhibitor of gelatinases MMP2 and MMP9 at its normal concentrations in extracellular fluid (ECF).
    Upadhya, GA
    Strasberg, SM
    HEPATOLOGY, 1999, 30 (04) : 311A - 311A
  • [30] FLUOROMETRIC-DETERMINATION OF OXIDIZED AND REDUCED GLUTATHIONE IN CELLS AND TISSUES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOLLOWING DERIVATIZATION WITH DANSYL CHLORIDE
    MARTIN, J
    WHITE, INH
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 568 (01): : 219 - 225