Preliminary In Vivo Testing of a Novel Pump for Short-Term Extracorporeal Life Support

被引:8
|
作者
Spurlock, David J.
Koch, Kelly
Mazur, Daniel E.
Fracz, Emilia M.
Bartlett, Robert H.
Haft, Jonathan W. [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Surg, Ann Arbor, MI 48109 USA
来源
ANNALS OF THORACIC SURGERY | 2012年 / 93卷 / 01期
关键词
VENTRICULAR ASSIST DEVICE; MECHANICAL CIRCULATORY SUPPORT; CARDIOPULMONARY BYPASS; FLOW; EXPERIENCE;
D O I
10.1016/j.athoracsur.2011.09.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Blood pumps used for temporary circulatory support have limitations. We propose a novel device designed for short-term extracorporeal support that is intrinsically volume responsive, afterload insensitive, and incapable of cavitation or excessive hemolysis. After in vitro testing, we performed the initial in vivo implantations and assessments. Methods. The BioVAD prototype (MC3, Inc, Ann Arbor, MI) was implanted in 6 adult male sheep (60.2 +/- 2.8 kg) through the left ventricular apex and descending thoracic aorta. Arterial, left and right atrial, and pump inlet and outlet pressures and BioVAD flow were measured and recorded. The animals were volume loaded to assess volume responsiveness, and the inlet lines were abruptly clamped during maximum support to observe for cavitation. An acute heart failure model was created with rapid ventricular pacing, and the animals were supported for 4 hours. Results. Peak flow was 3.19 +/- 0.56 L/min and increased to 3.71 +/- 0.53 L/min with 20 mm Hg vacuum-assisted drainage. Without manual changes in pump settings, pump flow increased 17.5% with volume loading. During acute venous line occlusion, there was no evidence of cavitation, and inlet suction was minimal. Hemodynamics were maintained for 4 hours during acute heart failure. Conclusions. The BioVAD provided adequate flow in an acute in vivo model. Its design may be superior for short-term extracorporeal support. (Ann Thorac Surg 2012;93:141-7) (C) 2012 by The Society of Thoracic Surgeons
引用
收藏
页码:141 / 147
页数:8
相关论文
共 50 条
  • [31] SHORT-TERM TESTING OF INDUSTRIAL CHEMICALS
    FERGUSON, DM
    CHEMISTRY & INDUSTRY, 1975, (10) : 416 - 418
  • [32] Perioperative Management of Patients Receiving Short-term Mechanical Circulatory Support with the Transvalvular Heart Pump
    Wu, Isaac Y.
    Wyrobek, Julie A.
    Naka, Yoshifumi
    Dickstein, Marc L.
    Glance, Laurent G.
    ANESTHESIOLOGY, 2022, 136 (05) : 829 - 842
  • [33] Long-term testing in a short-term world
    Rokosz, VT
    IEEE SOFTWARE, 2003, 20 (03) : 64 - +
  • [34] Extracorporeal Membrane Oxygenation and Short-Term Left Ventricular Assist Devices Support as the Bridge to Heart Transplantation
    Krachak, V.
    Shestakova, L.
    Krachak, D.
    EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 : 10 - 10
  • [35] Use of a novel short-term mechanical circulatory support device for cardiac recovery
    Anastasiadis, Kyriakos
    Antonitsis, Polychronis
    Chalvatzoutis, Omiros
    Papakonstantinou, Christos
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (06): : 732 - 733
  • [36] Testing novel methods for short-term forecasting of European glass eel recruitment
    Benezech, Mathilde
    Drouineau, Hilaire
    Acou, Anthony
    Bardonnet, Agn es
    Boulenger, Clarisse
    Lambert, Patrick
    Prevost, Etienne
    Beaulaton, Laurent
    FISHERIES RESEARCH, 2024, 271
  • [37] SHORT-TERM REPRODUCIBILITY OF INTRAVASCULAR ULTRASOUND IN VIVO
    Gunter Gorge
    Michael Haude
    Mahmoud Ashry
    Raimund Erbel
    Chinese Medical Journal, 1995, (03)
  • [38] SHORT-TERM REPRODUCIBILITY OF INTRAVASCULAR ULTRASOUND IN VIVO
    Gunter Gorge
    Michael Haude
    Mahmoud Ashry
    Raimund Erbel
    中华医学杂志(英文版), 1995, (03) : 77 - 78
  • [39] Pediatric Extracorporeal Life Support Using a Third Generation Diagonal Pump
    Speth, Marlene
    Muench, Frank
    Purbojo, Ariawan
    Gloeckler, Martin
    Toka, Okan
    Cesnjevar, Robert A.
    Rueffer, Andre
    ASAIO JOURNAL, 2016, 62 (04) : 482 - 490
  • [40] ROLE OF SHORT-TERM TESTING IN CARCINOGEN DETECTION
    BRUSICK, DJ
    CHEMOSPHERE, 1978, 7 (05) : 403 - 417