Carbon Paste Electrode Modified Molecularly Imprinted Polymer as a Sensor for Creatinine Analysis by Stripping Voltammetry

被引:3
|
作者
Khasanah, M. [1 ]
Darmokoesoemo, H.
Rizki, D. A. [1 ]
机构
[1] Airlangga Univ, Dept Chem, Fac Sci & Technol, Surabaya 60115, Indonesia
关键词
ASCORBIC-ACID; URIC-ACID; ELECTROCHEMICAL SENSOR; GLASSY-CARBON; FILM;
D O I
10.1063/1.5004310
中图分类号
O59 [应用物理学];
学科分类号
摘要
Modification of carbon paste electrode with molecularly imprinted polymer (CP-MIP) as a voltammetric sensor for creatinine has been developed. MIP was synthesized by reacting melamine, chloranil and creatinine with a mole ratio of 1: 1: 0.1. Creatinine was extracted from polymer chain by using hot water to form a specific imprinted for creatinine molecule. Carbon paste-MIP electrode was prepared by mixing activated carbon, solid paraffin, and MIP in a 45: 40: 15(w/w %) ratio. The optimum conditions of creatinine analysis by differential pulse stripping voltammetry (DPSV) using the developed electrode were the accumulation potential -1000 mV during 90 s at pH 5. The precision of the method for 0.1-0.5 g/L creatinine was 88.7-96.3%, while the detection limit of this method was 0.0315 g/L. The accuracy compared by spectrophotometric method was 95.3-103.6%
引用
收藏
页数:9
相关论文
共 50 条
  • [32] A chemometrics approach for simultaneous determination of cyanazine and propazine based on a carbon paste electrode modified by a molecularly imprinted polymer
    Gholivand, Mohammad Bagher
    Shariati-Rad, Masoud
    Karimian, Nashmil
    Torkashvand, Maryam
    ANALYST, 2012, 137 (05) : 1190 - 1198
  • [33] In Situ Voltammetric Determination of Promethazine on Carbon Paste Electrode Modified with Nano-sized Molecularly Imprinted Polymer
    Akhoundian, Maedeh
    Alizadeh, Taher
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (07): : 1014 - 1024
  • [34] Electroanalytical determination of sulfasalazine in pharmaceutical and biological samples using molecularly imprinted polymer modified carbon paste electrode
    Sadeghi, Susan
    Motaharian, Ali
    Moghaddam, Ali Zeraatkar
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 168 : 336 - 344
  • [35] Voltammetric determination of rivastigmine in pharmaceutical and biological samples using molecularly imprinted polymer modified carbon paste electrode
    Arvand, Majid
    Fallahi, Parisa
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 797 - 805
  • [36] Low-Range Detection of the Phosphate Group by a Molecularly Imprinted Polymer-Modified Carbon Paste Electrode
    Quint, Marcelo L.
    de Souza, Fernando S.
    Spinelli, Almir
    Domingos, Josiel B.
    IEEE SENSORS JOURNAL, 2015, 15 (02) : 1012 - 1019
  • [37] Carbon Paste Electrode Modified Imprinted Zeolite as a Selective Sensor for Creatine Analysis by Potentiometry
    Athiroh, A.
    Fadillah, T.
    Damayanti, D. F.
    Widati, A. A.
    Abdulloh, A.
    Khasanah, M.
    12TH CONGRESS OF INDONESIAN SOC. FOR BIOCHEMISTRY AND MOLECULAR BIOLOGY IN CONJUNCTION WITH THE 2ND INT. CONF COLLABORATION SEMINAR OF CHEMISTRY AND INDUSTRY (COSCI) AND ANMICRO WORKSHOP, 2018, 2019, 217
  • [38] Development of a Creatinine Sensor Based on a Molecularly Imprinted Polymer-Modified Sol-Gel Film on Graphite Electrode
    Patel, Amit Kumar
    Sharma, Piyush Sindhu
    Prasad, Bhim Bali
    ELECTROANALYSIS, 2008, 20 (19) : 2102 - 2112
  • [39] Electrochemical cholesterol sensor based on carbon nanotube@molecularly imprinted polymer modified ceramic carbon electrode
    Tong, Yuejin
    Li, Haidong
    Guan, Huaimin
    Zhao, Jianming
    Majeed, Saadat
    Anjum, Saima
    Liang, Feng
    Xu, Guobao
    BIOSENSORS & BIOELECTRONICS, 2013, 47 : 553 - 558
  • [40] Novel amperometric flow-injection analysis of creatinine using a molecularly-imprinted polymer coated copper oxide nanoparticle-modified carbon-paste-electrode
    Nontawong, Nongyao
    Amatatongchai, Maliwan
    Thimoonnee, Suphatsorn
    Laosing, Saowanee
    Jarujamrus, Purim
    Karuwan, Chanpen
    Chairam, Sanoe
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 175