15-O-water myocardial flow reserve PET and CT angiography by full hybrid PET/CT as a potential alternative to invasive angiography

被引:3
|
作者
Thomassen, Anders [1 ]
Braad, Poul-Erik [1 ]
Pedersen, Kasper T. [1 ]
Petersen, Henrik [1 ]
Johansen, Allan [1 ]
Diederichsen, Axel C. P. [2 ]
Mickley, Hans [2 ]
Jensen, Lisette O. [2 ]
Knuuti, Juhani [3 ,4 ]
Gerke, Oke [1 ]
Hoilund-Carlsen, Poul F. [1 ]
机构
[1] Odense Univ Hosp, Dept Nucl Med, Klovervaenget 47, DK-5000 Odense, Denmark
[2] Odense Univ Hosp, Dept Cardiol, Odense, Denmark
[3] Turku Univ Hosp, Turku, Finland
[4] Univ Turku, Turku, Finland
来源
关键词
Flow reserve; PET; 15-O-water; CT angiography; Diagnostic value; Reproducibility; CORONARY-ARTERY-DISEASE; BLOOD-FLOW; O-15-LABELED WATER; PERFUSION PET; RB-82; PET; REPRODUCIBILITY; N-13-AMMONIA; QUANTIFICATION; INTEROBSERVER; RELIABILITY;
D O I
10.1007/s10554-018-1420-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Combined myocardial flow reserve (MFR) by PET and CT coronary angiography (CTA) is a promising tool for assessment of coronary artery disease. Prior analyses of MFR/CTA has been performed as side-by-side interpretation, not as volume rendered, full hybrid analysis, with fused MFR/CTA. We aimed to: (i) establish a method for full hybrid analysis of MFR/CTA, (ii) validate the inter- and intra-observer reproducibility of MFR values, and (iii) determine the diagnostic value of side-by-side versus full hybrid MFR/CTA with 15-O-water PET. Forty-four outpatients scheduled for invasive coronary angiography (ICA) were enrolled prospectively. All underwent rest/stress 15-O-water PET/CTA with ICA as reference. Within two observers of different experience, the Pearson r at global and territorial level exceeded 0.953 for rest, stress, and MFR values, as determined by Carimas software. Within and between observers, the mean differences between rest, stress, and MFR values were close to zero and the confidence intervals for 95% limits of agreement were narrow. The diagnostic performance of full hybrid PET/CTA did not outperform the side-by-side approach, but performed better than MFR without CTA at vessel level: specificity 93% (95% confidence limits: 89-97%) versus 76% (64-88%), p=0.0004; positive predictive value 71% (55-86%) versus 51% (37-65%), p=0.0001; accuracy 90% (84-95%) versus 77% (69-84%), p=0.0009. MFR showed high reproducibility within and between observers of different experience. The full hybrid model was not superior to side-by-side interpretation of MFR/CTA, but proved better than MFR alone at vessel level with regard to specificity, positive predictive value, and accuracy.
引用
收藏
页码:2011 / 2022
页数:12
相关论文
共 50 条
  • [41] Effect of PET-CT misalignment on the quantitative accuracy of cardiac 15O-water PET
    Nordstrom, Jonny
    Harms, Hendrik J.
    Kero, Tanja
    Ebrahimi, Maryam
    Sorensen, Jens
    Lubberink, Mark
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (03) : 1119 - 1128
  • [42] SPECT/PET myocardial perfusion imaging versus coronary CT angiography in patients with known or suspected CAD
    Berman, D. S.
    Shaw, L. J.
    Min, J. K.
    Hachamovitch, R.
    Abidov, A.
    Germano, G.
    Hayes, S. W.
    Friedman, J. D.
    Thomson, L. E. J.
    Kang, X.
    Slomka, P.
    Rozanski, A.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 54 (02): : 177 - 200
  • [43] Effect of motion-induced PET-CT misalignment on cardiac function and myocardial blood flow measured using dynamic 15O-water PET
    Lubberink, M.
    Ebrahimi, M.
    Harms, H. J.
    Tolbod, L. Poulsen
    Sorensen, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S301 - S302
  • [44] Automatic quantification of regional myocardial blood flow and coronary flow reserve using 15O-water with PET.
    Katoh, C
    Yoshinaga, K
    Furuyama, H
    Noriyasu, K
    Mabuchi, M
    Nakada, K
    Tsukamoto, E
    Kuge, Y
    Tamaki, N
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 176P - 176P
  • [45] Cardiac PET-CT misregistration causes significant changes in myocardial flow reserve (MFR)
    Rajaram, Mahadevan
    Tahari, Abdel
    Fukushima, Kenji
    Lodge, Martin
    Tsui, Benjamin
    Nekolla, Stephan
    Wahl, Richard
    Bengel, Frank
    Bravo, Paco
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [46] Characterization of focal and diffuse coronary artery disease using coronary flow reserve and fractional flow reserve measured by N-13 ammonia PET and CT coronary angiography
    Cho, Sang-Geon
    Kang, Sae-Ryung
    Kim, Jahae
    Kim, Hyeon-Sik
    Park, Hee Jeong
    Cho, Jae Young
    Kwon, Seong Young
    Min, Jung Joon
    Song, Ho-Chun
    Bom, Hee-Seung
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [47] Measurement of tumor and myocardial perfusion using 15O-water and a clinical PET-CT scanner
    Lubberink, Mark
    van der Veldt, Astrid
    Knaapen, Paul
    Harms, Hans
    Smit, Egbert
    Hendrikse, Harry
    Lammertsma, Adriaan
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [48] The difference of myocardial flow reserve between DCM and dilated phase of HCM - Evaluation by O-15 water PET
    Ohba, M
    Hosokawa, R
    Kambara, N
    Tadamura, E
    Mamade, M
    Kubo, S
    Konishi, J
    Kimura, T
    Nohara, R
    Kita, T
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 204P - 204P
  • [49] Assessment of endothelial function and myocardial flow reserve using 15O-water PET without attenuation correction
    Tuffier, Stephane
    Legallois, Damien
    Belin, Annette
    Joubert, Michael
    Bailliez, Alban
    Redonnet, Michel
    Agostini, Denis
    Manrique, Alain
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (02) : 288 - 295
  • [50] Assessment of endothelial function and myocardial flow reserve using 15O-water PET without attenuation correction
    Stéphane Tuffier
    Damien Legallois
    Annette Belin
    Michael Joubert
    Alban Bailliez
    Michel Redonnet
    Denis Agostini
    Alain Manrique
    European Journal of Nuclear Medicine and Molecular Imaging, 2016, 43 : 288 - 295