15-O-water myocardial flow reserve PET and CT angiography by full hybrid PET/CT as a potential alternative to invasive angiography

被引:3
|
作者
Thomassen, Anders [1 ]
Braad, Poul-Erik [1 ]
Pedersen, Kasper T. [1 ]
Petersen, Henrik [1 ]
Johansen, Allan [1 ]
Diederichsen, Axel C. P. [2 ]
Mickley, Hans [2 ]
Jensen, Lisette O. [2 ]
Knuuti, Juhani [3 ,4 ]
Gerke, Oke [1 ]
Hoilund-Carlsen, Poul F. [1 ]
机构
[1] Odense Univ Hosp, Dept Nucl Med, Klovervaenget 47, DK-5000 Odense, Denmark
[2] Odense Univ Hosp, Dept Cardiol, Odense, Denmark
[3] Turku Univ Hosp, Turku, Finland
[4] Univ Turku, Turku, Finland
来源
关键词
Flow reserve; PET; 15-O-water; CT angiography; Diagnostic value; Reproducibility; CORONARY-ARTERY-DISEASE; BLOOD-FLOW; O-15-LABELED WATER; PERFUSION PET; RB-82; PET; REPRODUCIBILITY; N-13-AMMONIA; QUANTIFICATION; INTEROBSERVER; RELIABILITY;
D O I
10.1007/s10554-018-1420-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Combined myocardial flow reserve (MFR) by PET and CT coronary angiography (CTA) is a promising tool for assessment of coronary artery disease. Prior analyses of MFR/CTA has been performed as side-by-side interpretation, not as volume rendered, full hybrid analysis, with fused MFR/CTA. We aimed to: (i) establish a method for full hybrid analysis of MFR/CTA, (ii) validate the inter- and intra-observer reproducibility of MFR values, and (iii) determine the diagnostic value of side-by-side versus full hybrid MFR/CTA with 15-O-water PET. Forty-four outpatients scheduled for invasive coronary angiography (ICA) were enrolled prospectively. All underwent rest/stress 15-O-water PET/CTA with ICA as reference. Within two observers of different experience, the Pearson r at global and territorial level exceeded 0.953 for rest, stress, and MFR values, as determined by Carimas software. Within and between observers, the mean differences between rest, stress, and MFR values were close to zero and the confidence intervals for 95% limits of agreement were narrow. The diagnostic performance of full hybrid PET/CTA did not outperform the side-by-side approach, but performed better than MFR without CTA at vessel level: specificity 93% (95% confidence limits: 89-97%) versus 76% (64-88%), p=0.0004; positive predictive value 71% (55-86%) versus 51% (37-65%), p=0.0001; accuracy 90% (84-95%) versus 77% (69-84%), p=0.0009. MFR showed high reproducibility within and between observers of different experience. The full hybrid model was not superior to side-by-side interpretation of MFR/CTA, but proved better than MFR alone at vessel level with regard to specificity, positive predictive value, and accuracy.
引用
下载
收藏
页码:2011 / 2022
页数:12
相关论文
共 50 条
  • [1] 15-O-water myocardial flow reserve PET and CT angiography by full hybrid PET/CT as a potential alternative to invasive angiography
    Anders Thomassen
    Poul-Erik Braad
    Kasper T. Pedersen
    Henrik Petersen
    Allan Johansen
    Axel C. P. Diederichsen
    Hans Mickley
    Lisette O. Jensen
    Juhani Knuuti
    Oke Gerke
    Poul F. Høilund-Carlsen
    The International Journal of Cardiovascular Imaging, 2018, 34 : 2011 - 2022
  • [2] The effects of PET/CT misalignment on the quantification of myocardial blood flow in O-15 water myocardial PET/CT
    Ichikawa, Yasutaka
    Ishida, Masaki
    Tomita, Yoya
    Sakuma, Hajime
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [3] Automatic alignment of myocardial perfusion PET and 64-slice coronary CT angiography on hybrid PET/CT
    Ryo Nakazato
    Damini Dey
    Erick Alexánderson
    Aloha Meave
    Moisés Jiménez
    Edgar Romero
    Rodrigo Jácome
    Marco Peña
    Daniel S. Berman
    Piotr J. Slomka
    Journal of Nuclear Cardiology, 2012, 19 : 482 - 491
  • [4] Automatic alignment of myocardial perfusion PET with 64-slice coronary CT angiography on hybrid PET/CT
    Nakazato, Ryo
    Slomka, Piotr
    Alexanderson, Erick
    Meave, Aloha
    Jimenez-Santos, Moises
    Romero, Edgar
    Jacome, Rodrigo
    Pena, Marco
    Dey, Damini
    Berman, Daniel
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [5] Automatic alignment of myocardial perfusion PET and 64-slice coronary CT angiography on hybrid PET/CT
    Nakazato, Ryo
    Dey, Damini
    Alexanderson, Erick
    Meave, Aloha
    Jimenez, Moises
    Romero, Edgar
    Jacome, Rodrigo
    Pena, Marco
    Berman, Daniel S.
    Slomka, Piotr J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (03) : 482 - 491
  • [6] Hybrid CT angiography and quantitative 15O-water PET for assessment of coronary artery disease: comparison with quantitative coronary angiography
    Thomassen, Anders
    Petersen, Henrik
    Diederichsen, Axel C. P.
    Mickley, Hans
    Jensen, Lisette O.
    Johansen, Allan
    Gerke, Oke
    Braad, Poul-Erik
    Thayssen, Per
    Hoilund-Carlsen, Mette M.
    Vach, Werner
    Knuuti, Juhani
    Hoilund-Carlsen, Poul F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (12) : 1894 - 1904
  • [7] Hybrid CT angiography and quantitative 15O-water PET for assessment of coronary artery disease: comparison with quantitative coronary angiography
    Anders Thomassen
    Henrik Petersen
    Axel C. P. Diederichsen
    Hans Mickley
    Lisette O. Jensen
    Allan Johansen
    Oke Gerke
    Poul-Erik Braad
    Per Thayssen
    Mette M. Høilund-Carlsen
    Werner Vach
    Juhani Knuuti
    Poul F. Høilund-Carlsen
    European Journal of Nuclear Medicine and Molecular Imaging, 2013, 40 : 1894 - 1904
  • [8] Effect of cardiac hybrid 15O-water PET/CT imaging on downstream referral for invasive coronary angiography and revascularization rate
    Danad, Ibrahim
    Raijmakers, Pieter G.
    Harms, Hendrik J.
    van Kuijk, Cornelis
    van Royen, Niels
    Diamant, Michaela
    Lammertsma, Adriaan A.
    Lubberink, Mark
    van Rossum, Albert C.
    Knaapen, Paul
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (02) : 170 - 179
  • [9] Coronary CT Angiography With PET Perfusion Imaging Hybrid or Hype?
    Gould, K. Lance
    Johnson, Nils P.
    JACC-CARDIOVASCULAR IMAGING, 2017, 10 (11) : 1371 - 1373
  • [10] Low radiation dose imaging of myocardial perfusion and coronary angiography with a hybrid PET/CT scanner
    Kajander, S.
    Ukkonen, H.
    Sipila, H.
    Teras, M.
    Knuuti, J.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2009, 29 (01) : 81 - 88