Behaviour of Belle II ARICH Hybrid Avalanche Photo-Detector in magnetic field

被引:1
|
作者
Kindo, H. [1 ]
Adachi, I. [1 ,2 ]
Dolenec, R. [6 ]
Hataya, K. [3 ]
Iori, S. [4 ]
Iwata, S. [3 ]
Kakuno, H. [3 ]
Kataura, R. [5 ]
Kawai, H.
Kobayashi, T. [5 ]
Konno, T. [2 ]
Korpar, S. [6 ,8 ]
Krizan, P. [6 ,7 ]
Kumita, T. [3 ]
Mrvar, M. [6 ]
Nishida, S. [1 ,2 ]
Ogawa, K. [5 ]
Ogawa, S. [4 ]
Pestotnik, R. [6 ]
Santelj, L. [2 ]
Sumiyoshi, T. [3 ]
Tabata, M. [9 ]
Yonenaga, M. [3 ]
Yusa, Y. [5 ]
机构
[1] SOKENDAI Grad Univ Adv Sci, Tsukuba, Ibaraki, Japan
[2] High Energy Accelerator Res Org KEK, Tsukuba, Ibaraki, Japan
[3] Tokyo Metropolitan Univ, Hachioji, Tokyo, Japan
[4] Toho Univ, Funabashi, Chiba, Japan
[5] Niigata Univ, Niigata, Japan
[6] Inst Jozef Stefan, Ljubljana, Slovenia
[7] Univ Ljubljana, Ljubljana, Slovenia
[8] Univ Maribor, Maribor, Slovenia
[9] Chiba Univ, Chiba, Japan
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2017年 / 876卷
关键词
Belle II; ARICH; Magnetic field;
D O I
10.1016/j.nima.2017.04.044
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The proximity-focusing Aerogel Ring-Imaging Cherenkov detector (ARICH) has been designed to separate kaons from pions in the forward end-cap of the Belle II spectrometer. The detector will be placed in 1.5 T magnetic field and must have immunity to it. In ARICH R&D, we solve the problem with new equipment called Hybrid Avalanche Photo-Detector (HAPD) which developed by Hamamatsu Photonics. Recently the production of about 500 HAPDs was completed. We test HAPDs in magnetic field in KEK. We found some HAPDs have significant amount of dead time, which reaches up to 30% in the worst case. The dead time is caused by very large (more than 10,000 times larger than a single photon signal) and frequent (similar to 5 Hz) signals, which make electronics paralysed. The huge signals are observed in about 30% of HAPDs. To identify the origin and understand the mechanism, we perform some extra test of HAPDs. We find a strange dependence of the huge signals to the APD bias voltage. If we reduce the bias voltage applied to one of the 4 APDs by 10 V, the frequency of the huge signals is much reduced. On the other hand, if we reduce the voltage of all the 4 HAPDs, huge signals do not decrease, or even increase in some case. We also find the huge signals seems to be related to the vacuum inside HAPD. We present about the observation of the huge signals of HAPDs in the magnetic field, and our strategy to manage it. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:269 / 271
页数:3
相关论文
共 49 条
  • [32] A Novel Hybrid Microdosimeter for Radiation Field Characterization Based on the Tissue Equivalent Proportional Counter Detector and Low Gain Avalanche Detectors Tracker: A Feasibility Study
    Missiaggia, M.
    Pierobon, E.
    Castelluzzo, M.
    Perinelli, A.
    Cordoni, F.
    Centis Vignali, M.
    Borghi, G.
    Bellinzona, E. V.
    Scifoni, E.
    Tommasino, F.
    Monaco, V.
    Ricci, L.
    Boscardin, M.
    La Tessa, Chiara
    FRONTIERS IN PHYSICS, 2021, 8
  • [33] Magnetic field dependence of 13C photo-CIDNP MAS NMR in plant photosystems I and II
    Roy, E.
    Diller, A.
    Alia
    Gast, P.
    van Gorkom, H. J.
    de Groot, H. J. M.
    Jeschke, G.
    Matysik, J.
    APPLIED MAGNETIC RESONANCE, 2007, 31 (1-2) : 193 - 204
  • [34] Magnetic field dependence of13C photo-CIDNP MAS NMR in plant photosystems I and II
    E. Roy
    A. Diller
    P. Alia
    H. J. Gast
    H. J. M. van Gorkom
    G. de Groot
    J. Jeschke
    Applied Magnetic Resonance, 2007, 31 : 193 - 204
  • [35] Field Induced Single Ion Magnetic Behaviour in Square-Pyramidal Cobalt(II) Complexes with Easy-Plane Magnetic Anisotropy
    Mondal, Amit Kumar
    Mondal, Arpan
    Konar, Sanjit
    MAGNETOCHEMISTRY, 2019, 5 (01)
  • [36] The behaviour of gas bubbles in a turbulent liquid metal magnetohydrodynamic flow - Part II: Magnetic field influence on the slip ratio
    Eckert, S
    Gerbeth, G
    Lielausis, Q
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2000, 26 (01) : 67 - 82
  • [37] Magnetic field dynamics and noise analysis for space-based GW detector in far-earth orbits: A hybrid modeling approach
    Low, Kian Hong
    Wen, Qian
    Wang, ZhaoKui
    ACTA ASTRONAUTICA, 2024, 224 : 99 - 111
  • [38] Exposures Representative of Traction Current Magnetic Fields in Hybrid and Electric Vehicles - II: Safety Factors Provided by Field Reference Levels
    Ruddle, Alastair R.
    Low, Lester
    2014 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2014, : 354 - 359
  • [39] Magnetic Field-Modulated Plasmonic Scattering of Hybrid Nanorods for FFT-Weighted OCT Imaging in NIR-II
    Li, Zhiwei
    Poon, Wesley
    Ye, Zuyang
    Qi, Fenglian
    Park, Hyle
    Yin, Yadong
    ACS NANO, 2022, 16 (08) : 12738 - 12746
  • [40] A C,S bonded quasi-two-coordinate chromium(ii) complex showing field-induced slow magnetic relaxation behaviour
    Luo, Qian-Cheng
    Ge, Ning
    Zhai, Yuan-Qi
    Wang, Teng-Bo
    Sun, Lin
    Sun, Qi
    Li, Fanni
    Ouyang, Zhongwen
    Wang, Zhen-Xing
    Zheng, Yan-Zhen
    DALTON TRANSACTIONS, 2022, 51 (24) : 9218 - 9222