Behaviour of Belle II ARICH Hybrid Avalanche Photo-Detector in magnetic field

被引:1
|
作者
Kindo, H. [1 ]
Adachi, I. [1 ,2 ]
Dolenec, R. [6 ]
Hataya, K. [3 ]
Iori, S. [4 ]
Iwata, S. [3 ]
Kakuno, H. [3 ]
Kataura, R. [5 ]
Kawai, H.
Kobayashi, T. [5 ]
Konno, T. [2 ]
Korpar, S. [6 ,8 ]
Krizan, P. [6 ,7 ]
Kumita, T. [3 ]
Mrvar, M. [6 ]
Nishida, S. [1 ,2 ]
Ogawa, K. [5 ]
Ogawa, S. [4 ]
Pestotnik, R. [6 ]
Santelj, L. [2 ]
Sumiyoshi, T. [3 ]
Tabata, M. [9 ]
Yonenaga, M. [3 ]
Yusa, Y. [5 ]
机构
[1] SOKENDAI Grad Univ Adv Sci, Tsukuba, Ibaraki, Japan
[2] High Energy Accelerator Res Org KEK, Tsukuba, Ibaraki, Japan
[3] Tokyo Metropolitan Univ, Hachioji, Tokyo, Japan
[4] Toho Univ, Funabashi, Chiba, Japan
[5] Niigata Univ, Niigata, Japan
[6] Inst Jozef Stefan, Ljubljana, Slovenia
[7] Univ Ljubljana, Ljubljana, Slovenia
[8] Univ Maribor, Maribor, Slovenia
[9] Chiba Univ, Chiba, Japan
关键词
Belle II; ARICH; Magnetic field;
D O I
10.1016/j.nima.2017.04.044
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The proximity-focusing Aerogel Ring-Imaging Cherenkov detector (ARICH) has been designed to separate kaons from pions in the forward end-cap of the Belle II spectrometer. The detector will be placed in 1.5 T magnetic field and must have immunity to it. In ARICH R&D, we solve the problem with new equipment called Hybrid Avalanche Photo-Detector (HAPD) which developed by Hamamatsu Photonics. Recently the production of about 500 HAPDs was completed. We test HAPDs in magnetic field in KEK. We found some HAPDs have significant amount of dead time, which reaches up to 30% in the worst case. The dead time is caused by very large (more than 10,000 times larger than a single photon signal) and frequent (similar to 5 Hz) signals, which make electronics paralysed. The huge signals are observed in about 30% of HAPDs. To identify the origin and understand the mechanism, we perform some extra test of HAPDs. We find a strange dependence of the huge signals to the APD bias voltage. If we reduce the bias voltage applied to one of the 4 APDs by 10 V, the frequency of the huge signals is much reduced. On the other hand, if we reduce the voltage of all the 4 HAPDs, huge signals do not decrease, or even increase in some case. We also find the huge signals seems to be related to the vacuum inside HAPD. We present about the observation of the huge signals of HAPDs in the magnetic field, and our strategy to manage it. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:269 / 271
页数:3
相关论文
共 49 条
  • [1] Studies of a hybrid avalanche photo-detector in magnetic field
    Santelj, L.
    Adachi, I.
    Hataya, K.
    Iori, S.
    Iwata, S.
    Kakuno, H.
    Kataura, R.
    Kawai, H.
    Kindo, H.
    Korpar, S.
    Krizan, P.
    Mrvar, M.
    Nath, K.
    Nishida, S.
    Ogawa, S.
    Pestotnik, R.
    Stanovnik, A.
    Seljak, A.
    Sumiyoshi, T.
    Tabata, M.
    Tahirovic, E.
    Yusa, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 845 : 459 - 462
  • [2] Study of 144-channel hybrid avalanche photo-detector for Belle II RICH counter
    Shiizuka, Susumu
    Adachi, Ichiro
    Dolenec, Rok
    Hara, Koji
    Iijima, Toru
    Ikeda, Hirokazu
    Imamura, Miki
    Iwata, Syuuichi
    Korpar, Samo
    Krizan, Peter
    Kumita, Tetsuro
    Kuroda, Eiryo
    Nishida, Shohei
    Ogawa, Satoru
    Pestotnik, Rok
    Santelj, Luka
    Sumiyoshi, Takayuki
    Tabata, Makoto
    Tagai, Rie
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01): : 315 - 318
  • [3] Study of a 144 channel multi-anode hybrid avalanche photo-detector for the Belle II RICH counter
    Adachi, I.
    Dolenec, R.
    Hara, K.
    Iijima, T.
    Imamura, M.
    Iwata, S.
    Kawai, H.
    Korpar, S.
    Krizan, P.
    Kumita, T.
    Kuroda, E.
    Nishida, S.
    Ogawa, S.
    Pestotnik, R.
    Shiizuka, S.
    Sumiyoshi, T.
    Tabata, M.
    Tagai, S.
    Verheyden, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 639 (01): : 103 - 106
  • [4] Study of 144-ch Hybrid Avalanche Photo-Detector with High Density Electronics System for Belle-II RICH Counter
    Iwata, S.
    Adachi, I.
    Hara, K.
    Iijima, T.
    Ikeda, H.
    Imamura, M.
    Kawai, H.
    Kubo, M.
    Kumita, T.
    Korpar, S.
    Nishida, S.
    Ogawa, R.
    Seljak, A.
    Sumiyoshi, T.
    Suzuki, A.
    Tabata, M.
    Takagaki, H.
    Tagai, S.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 828 - 831
  • [5] Development of a 144-channel Hybrid Avalanche Photo-Detector for Belle II ring-imaging Cherenkov counter with an aerogel radiator
    Nishida, S.
    Adachi, I.
    Hamada, N.
    Hara, K.
    Iijima, T.
    Iwata, S.
    Kakuno, H.
    Kawai, H.
    Korpar, S.
    Krizan, R.
    Ogawa, S.
    Pestotnik, R.
    Santelj, L.
    Seljak, A.
    Sumiyoshi, T.
    Tabata, M.
    Tahirovic, E.
    Yoshida, K.
    Yusa, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 59 - 63
  • [6] Development of Large-Aperture Hybrid Avalanche Photo-Detector
    Abe, T.
    Aihara, H.
    Tanaka, M.
    Kawai, Y.
    Kyushima, H.
    Suyama, M.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2187 - +
  • [7] Study of 144-channel multi-anode hybrid avalanche photo-detector for the Belle RICH counter
    Adachi, I.
    Dolenec, R.
    Hara, K.
    Iijima, T.
    Ishii, Y.
    Kawai, H.
    Korpar, S.
    Krizan, P.
    Kumita, T.
    Kuroda, E.
    Miyazawa, Y.
    Nishida, S.
    Nishizawa, I.
    Ogawa, S.
    Pestotnik, R.
    Sawafuji, N.
    Shiizuka, S.
    Sumiyoshi, T.
    Tabata, M.
    Ueki, Y.
    Unno, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 285 - 287
  • [8] Development of a 13-in. Hybrid Avalanche Photo-Detector (HAPD) for a next generation water Cherenkov detector
    Nakayama, H.
    Kusaka, A.
    Kakuno, H.
    Abe, T.
    Iwasaki, M.
    Aihara, H.
    Shiozawa, M.
    Tanaka, M.
    Kyushima, H.
    Suyama, M.
    Kawai, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01): : 172 - 175
  • [9] R&D status of a large-aperture hybrid avalanche photo-detector
    Abe, Toshinori
    Aihara, Hiroaki
    Iwasaki, Masako
    Fujimori, Hiroki
    Kasimura, Keizo
    Mineo, Sogo
    Uchida, Tomohisa
    Tanaka, Manobu
    Kawai, Yoshihiko
    Kyushima, Hiroyuki
    Suyama, Motohiro
    Shiozawa, Masato
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 279 - 281
  • [10] Large-aperture hybrid photo-detector
    Kawai, Y.
    Nakayama, H.
    Kusaka, A.
    Kakuno, H.
    Abe, T.
    Iwasaki, M.
    Alhara, H.
    Tanaka, M.
    Shiozawa, M.
    Kyushima, H.
    Suyama, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 42 - 45