Nickel-gold plating of copper PCB traces and signal losses

被引:3
|
作者
Gaudion, Martyn
机构
[1] Polar Instruments Ltd, St Sampson, Guernsey
关键词
Printed-circuit boards; Signal processing; Digital technology; Copper; Nickel; Gold; Solderable finish; Insertion loss; PCB signal integrity; Skin depth; Attenuation; Selective plating; Digital applications; Ultra high frequency effects; Ni-Au;
D O I
10.1108/03056121211222264
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Purpose - The purpose of this paper is to discuss nickel gold plating of PCB traces and its adverse effects on signal integrity, and to explore the other key drivers in optimising yields and controlling PCB processes that impinge on signal integrity. Design/methodology/approach - The paper is a response to requests from PCB fabricators to explain why the losses on impedance controlled traces on PCBs were sometimes higher than expected. Findings - While nickel is acceptable on short lengths of pad to accommodate gold plating, plating the whole trace length is generally not good practice from a digital signal integrity perspective. In addition, with the fastest serial transmission rates in the 10 to 20 GHz region and long serial words in some situations designers may need to consider both the associated high and low frequency performance. Originality/value - With the development of ultra high speed digital bus architectures, PCB fabricators will appreciate the need to add an understanding of the drivers of insertion loss (base material loss tangent data, foil roughness and copper cross sectional areas) to their existing experience of architectures with minimal losses.
引用
收藏
页码:64 / 67
页数:4
相关论文
共 50 条
  • [21] INVESTIGATION OF INITIAL STAGES OF DECOMPOSITION AND SOLUTION IN NICKEL-GOLD ALLOY
    SANADZE, VV
    STAMATEL.YI
    KUTELIYA, ER
    SOVIET PHYSICS CRYSTALLOGRAPHY, USSR, 1970, 15 (03): : 408 - &
  • [22] DISSOLUTION OF PHASES IN NICKEL-GOLD SYSTEM DURING ISOTHERMAL ANNEALING
    SANADZE, VV
    GULYAEV, GV
    SOVIET PHYSICS CRYSTALLOGRAPHY, USSR, 1967, 11 (04): : 499 - &
  • [23] RAPID ANALYSIS AND TROUBLESHOOTING OF GOLD, NICKEL, AND COPPER PLATING BATH CHEMISTRY BY CHROMATOGRAPHY
    HAAK, KK
    FRANKLIN, GO
    PLATING AND SURFACE FINISHING, 1983, 70 (05): : 22 - 22
  • [24] Break through developments in electroless nickel/gold plating on copper based semiconductors
    Strandjord, AJG
    Popelar, SF
    Erickson, CA
    INTERNATIONAL SYMPOSIUM ON ADVANCED PACKAGING MATERIALS: PROCESSES, PROPERTIES AND INTERFACES, PROCEEDINGS, 2000, : 107 - 111
  • [25] Residual Stresses During Aging of a Nickel-Beryllium and a Nickel-Gold Alloy.
    Koester, Werner
    Zeitschrift fuer Metallkunde/Materials Research and Advanced Techniques, 1988, 79 (02): : 71 - 73
  • [26] RESIDUAL-STRESSES DURING AGING OF A NICKEL-BERYLLIUM AND A NICKEL-GOLD ALLOY
    KOSTER, W
    ZEITSCHRIFT FUR METALLKUNDE, 1988, 79 (02): : 71 - 73
  • [27] Nickel free gold plating technology
    Day, AE
    Sundaram, V
    TRANSACTIONS OF THE METAL FINISHERS ASSOCIATION OF INDIA, 1997, 6 (02): : 125 - 130
  • [28] Hydrogen co-production via nickel-gold electrocatalysis of water and formaldehyde
    Li, Zhixin
    Zhang, Yan
    Yang, Qianqian
    Wu, Jindong
    Ren, Zhi
    Si, Fengzhan
    Zhao, Jing
    Chen, Jiean
    ISCIENCE, 2023, 26 (10)
  • [29] LASER ENHANCED SELECTIVE GOLD PLATING ON NICKEL PLATED BULK COPPER-ALLOYS
    GELCHINSKI, MH
    ROMANKIW, LT
    VONGUTFELD, RJ
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1982, 129 (08) : C323 - C324
  • [30] The effect of waveform for pulse plating on copper plating distribution of microvia in PCB manufacture
    K. C. Yung
    K. C. Chan
    T. M. Yue
    K. F. Yeung
    The International Journal of Advanced Manufacturing Technology, 2004, 23 : 245 - 248