A Piezoelectric Goniometer Inside a Transmission Electron Microscope Goniometer

被引:3
|
作者
Guan, Wei [1 ]
Lockwood, Aiden [1 ]
Inkson, Beverley J. [1 ]
Moebus, Guenter [1 ]
机构
[1] Univ Sheffield, Dept Mat Sci & Engn, NanoLAB Ctr, Sheffield S1 3JD, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
in situ TEM; electron tomography; nanomanipulation; piezo drive; SCANNING TUNNELING MICROSCOPE; IN-SITU NANOINDENTATION; TOMOGRAPHY; HOLDER;
D O I
10.1017/S143192761100050X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Piezoelectric nanoactuators, which can provide extremely stable and reproducible positioning, are rapidly becoming the dominant means for position control in transmission electron microscopy. Here we present a second-generation miniature goniometric nanomanipulation system, which is fully piezo-actuated with ultrafine step size for translation and rotation, programmable, and can be fitted inside a hollowed standard specimen holder for a transmission electron microscope (TEM). The movement range of this miniaturized drive is composed of seven degrees of freedom: three fine translational movements (X, Y, and Z axes), three coarse translational movements along all three axes, and one rotational movement around the X-axis with an integrated angular sensor providing absolute rotation feedback. The new piezoelectric system independently operates as a goniometer inside the TEM goniometer. In situ experiments, such as tomographic tilt without missing wedge and differential tilt between two specimens, are demonstrated.
引用
收藏
页码:827 / 833
页数:7
相关论文
共 50 条
  • [21] IMPROVEMENT OF TRANSLATION STAGE FOR TRANSMISSION TOPOGRAPHIC GONIOMETER
    MIDDLETON, RM
    CASLAVSKY, JL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (11): : 1662 - +
  • [22] GRAVITY GONIOMETER
    BROWN, RK
    STEVENSON, BR
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1953, 35-A (03): : 784 - 785
  • [23] JAW GONIOMETER
    PENDLETON, TB
    COLEMAN, MM
    GROSSMAN, BJ
    PHYSICAL THERAPY, 1974, 54 (01): : 23 - 25
  • [24] GIMBAL GONIOMETER
    COLE, H
    OKRASINSKI, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (09): : 942 - &
  • [25] The standardisation of goniometer
    Fusgen, P
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1927, 71 : 1203 - 1204
  • [26] METHOD OF USING INCIDENT BEAM TILT AS A EUCENTRIC GONIOMETER IN TRANSMISSION ELECTRON-MICROSCOPY
    VINGSBO, O
    YANAKA, T
    SHIROTA, K
    ULTRAMICROSCOPY, 1975, 1 (02) : 121 - 126
  • [27] A FINGER GONIOMETER
    OSBORNE, G
    LANCET, 1962, 2 (7253): : 435 - &
  • [28] A PRESET GONIOMETER-TYPE SPECIMEN HOLDER FOR PHILIPS EM-200 ELECTRON MICROSCOPE
    FOURIE, JT
    VANDENBO.FJ
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1965, 42 (02): : 129 - &
  • [29] Goniometer upgrade
    不详
    OPTICS AND LASER TECHNOLOGY, 1999, 31 (01): : VII - VII
  • [30] AN OPTICAL GONIOMETER
    LOGAN, JK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1953, 24 (09): : 885 - 886