Subharmonic contrast intravascular ultrasound

被引:1
|
作者
Goertz, David E. [1 ]
Frijlink, Martijn E. [1 ]
Tempel, Dennie [1 ]
Krams, Robert [1 ]
de Jong, Nico [1 ]
van der Steen, Antonius F. W. [1 ]
机构
[1] Erasmus MC, Dept Biomed Engn, Rotterdam, Netherlands
关键词
intravascular ultrasound; contrast agents; vasa vasorum; atherosclerosis; coronary artery; vulnerableplaque;
D O I
10.1109/ULTSYM.2007.269
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The feasibility of subharmonic contrast intravascular ultrasound (IVUS) imaging was investigated using a prototype nonlinear IVUS system and the commercial contrast agent Definity (TM). The system employed a mechanically scanned commercial catheter with a custom transducer element fabricated to have dual frequency peak sensitivity in the vicinity of 15 and 30 MHz. Experiments were conducted at a fundamental frequency of 30 MHz (F30; 25% bandwidth) with on-axis pressures ranging from 0.12 to 0.79 MPa, as measured with needle a hydrophone. In vitro characterization experiments demonstrated the detection of 15 MHz subharmonic signals (SH15) when pressure levels reached 360 kPa. The formation of SH15 images was shown, with tissue signals suppressed to near the noise floor and contrast to tissue ratios improved by up to 30 dB relative to F30, depending on the depth. In vivo experiments were performed using the atherosclerotic rabbit aorta model. Following the bolus injection of contrast agent upstream of the imaging catheter, agent was detected within the aorta, vena cava, and within the adventitia. Histology confirmed the presence of adventitial microvessels. These results provide a first in vivo demonstration of subharmonic contrast IVUS, and suggest its potential as a new technique for imaging the vasa vasorum.
引用
收藏
页码:1065 / 1068
页数:4
相关论文
共 50 条
  • [1] Subharmonic contrast intravascular ultrasound for vasa vasorum imaging
    Goertz, David E.
    Frijlink, Martijn E.
    Tempel, Dennie
    Bhagwandas, Vijay
    Gisolf, Andries
    Krams, Robert
    de Jong, Nico
    van der Steen, Antonius F. W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (12): : 1859 - 1872
  • [2] Subharmonic backscattering from ultrasound contrast agents
    Shankar, PM
    Krishna, PD
    Newhouse, VL
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 106 (04): : 2104 - 2110
  • [3] INTRAVASCULAR ULTRASOUND CONTRAST-MEDIA
    SCHMID, V
    LANG, JH
    [J]. VETERINARY RADIOLOGY & ULTRASOUND, 1995, 36 (04) : 307 - 314
  • [4] The Effect of Mixing Iodinated Contrast Media and Ultrasound Contrast Agents on Subharmonic Signals
    Esposito, Cara
    Tzan, Kenneth
    Machado, Priscilla
    Forsberg, Flemming
    Dave, Jaydev K.
    [J]. ULTRASONIC IMAGING, 2024, 46 (02) : 130 - 134
  • [5] COMBINING SUBHARMONIC AND ULTRAHARMONIC MODES FOR INTRAVASCULAR ULTRASOUND IMAGING: A PRELIMINARY EVALUATION
    Shekhar, Himanshu
    Rowan, Jeffrey S.
    Doyley, Marvin M.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (11): : 2725 - 2732
  • [6] Active control of subharmonic response of ultrasound contrast agent microbubbles
    Faez, T.
    Renaud, G.
    Defontaine, M.
    Calle, S.
    De Jong, N.
    [J]. 2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 172 - 175
  • [7] Subharmonic resonance of phospholipid coated ultrasound contrast agent microbubbles
    Yusefi, Hossein
    Helfield, Brandon
    [J]. ULTRASONICS SONOCHEMISTRY, 2024, 102
  • [8] The subharmonic resonance of lipid-encapsulated ultrasound contrast agents
    Yusefi, Hossein
    Helfield, Brandon
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):
  • [9] Recent Experiences and Advances in Contrast-Enhanced Subharmonic Ultrasound
    Eisenbrey, John R.
    Sridharan, Anush
    Liu, Ji-Bin
    Forsberg, Flemming
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [10] Zero-Contrast Intravascular Lithotripsy Angioplasty Facilitated by Intravascular Ultrasound
    Kass, Malek
    Love, Michael P.
    Ravandi, Amir