Subharmonic backscattering from ultrasound contrast agents

被引:101
|
作者
Shankar, PM [1 ]
Krishna, PD
Newhouse, VL
机构
[1] Drexel Univ, Dept Elect & Comp Engn, Philadelphia, PA 19104 USA
[2] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
[3] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Dept Elect & Comp Engn, Philadelphia, PA 19104 USA
来源
关键词
D O I
10.1121/1.428142
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The ultrasonic contrast of blood in tissue, which is needed for ultrasonic estimation of tissue perfusion, can be increased by injecting the blood with bubbles or hollow microspheres. It has been shown that an even greater improvement in contrast can be obtained by using the subharmonic generated by irradiated microspheres. By obtaining analytical solutions to the modified RPNNP equation for a coated microbubble, the relationship between the physical parameters of the encapsulated bubble and the threshold pressure is established. The observed increase in the resonance frequency of a coated microsphere is explained by introducing the concept of "acoustic radius" of the encapsulated bubble. It is predicted that subharmonic generation in contrast agents requires a threshold insonifying pressure, and should be a minimum when microspheres are insonated at twice their resonance frequency. Experiments confirm the existence of this optimum incident frequency and of a reasonably low threshold pressure for the generation of the subharmonic. The existence of the low threshold pressures for subharmonic generation in contrast agents may prove to be very valuable in ultrasonic contrast imaging. (C) 1999 Acoustical Society of America. [S0001-4966(99)01510-6].
引用
收藏
页码:2104 / 2110
页数:7
相关论文
共 50 条
  • [1] Subharmonic backscattering from ultrasound contrast agents
    Shankar, P.M.
    Krishna, P.D.
    Newhouse, V.L.
    [J]. Journal of the Acoustical Society of America, 1999, 106 (4 I): : 2104 - 2110
  • [2] Subharmonic backscattering from ultrasound contrast agents
    Shankar, P.M.
    Krishna, P.D.
    Newhouse, V.L.
    [J]. Journal of the Acoustical Society of America, 1999, 106 (4 pt 1):
  • [3] Processing of Subharmonic Signals from Ultrasound Contrast Agents to Determine Ambient Pressures
    Dave, Jaydev K.
    Halldorsdottir, Valgerdur G.
    Eisenbrey, John R.
    Forsberg, Flemming
    [J]. ULTRASONIC IMAGING, 2012, 34 (02) : 81 - 92
  • [4] The Effect of Mixing Iodinated Contrast Media and Ultrasound Contrast Agents on Subharmonic Signals
    Esposito, Cara
    Tzan, Kenneth
    Machado, Priscilla
    Forsberg, Flemming
    Dave, Jaydev K.
    [J]. ULTRASONIC IMAGING, 2024, 46 (02) : 130 - 134
  • [5] The subharmonic resonance of lipid-encapsulated ultrasound contrast agents
    Yusefi, Hossein
    Helfield, Brandon
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):
  • [6] Subharmonic generation from ultrasonic contrast agents
    Krishna, PD
    Shankar, PM
    Newhouse, VL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (03): : 681 - 694
  • [7] IMPACT OF FILLING GAS ON SUBHARMONIC EMISSIONS OF PHOSPHOLIPID ULTRASOUND CONTRAST AGENTS
    Kanbar, Emma
    Fouan, Damien
    Sennoga, Charles A.
    Doinikov, Alexander A.
    Bouakaz, Ayache
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (05): : 1004 - 1015
  • [8] Subharmonic contrast intravascular ultrasound
    Goertz, David E.
    Frijlink, Martijn E.
    Tempel, Dennie
    Krams, Robert
    de Jong, Nico
    van der Steen, Antonius F. W.
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1065 - 1068
  • [9] Parametric Imaging Using Subharmonic Signals From Ultrasound Contrast Agents in Patients With Breast Lesions
    Eisenbrey, John R.
    Dave, Jaydev K.
    Merton, Daniel A.
    Palazzo, Juan P.
    Hall, Anne L.
    Forsberg, Flemming
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (01) : 85 - 92
  • [10] Subharmonic imaging of contrast agents
    Forsberg, F
    Shi, WT
    Goldberg, BB
    [J]. ULTRASONICS, 2000, 38 (1-8) : 93 - 98