The potential impact of the small-scale ejector on the R744 transcritical refrigeration system

被引:11
|
作者
Elbarghthi, Anas F. A. [1 ]
Dvorak, Vaclav [1 ]
Hafner, Armin [2 ]
Banasiak, Krzysztof [3 ]
机构
[1] Tech Univ Liberec, Fac Mech Engn, Dept Appl Mech, Studentska 1402-2, Liberec 46117, Czech Republic
[2] NTNU Dept Energy & Proc Engn, Kolbjorn Hejes Vei 1d, N-7465 Trondheim, Norway
[3] SINTEF Energy Res, N-7465 Trondheim, Norway
关键词
Ejector; CO2; Work recovery; COP; Exergy destruction; Power consumption; Efficiency; CO2; HEAT-PUMP; ADVANCED EXERGY ANALYSIS; MULTI-EJECTOR; SUPERMARKET REFRIGERATION; PERFORMANCE; CYCLE; OPTIMIZATION; PRESSURE; GEOMETRY; DESIGN;
D O I
10.1016/j.enconman.2021.114860
中图分类号
O414.1 [热力学];
学科分类号
摘要
The evident adverse effects of climate change and the consequences of global warming has left an exigent circumstance requiring crucial actions on the applications and technology of refrigeration and air conditioning systems as it concerns its tremendous indirect contributions to greenhouse gas emissions. This field has witnessed steady expansion in recent times. The attendant high-grade energy consumption calls for pragmatic approaches to developing innovative technologies aimed at energy management and finding measures to curb global warming. This current study intends to illustrate the impact of implementing a small-size ejector profile on the R744 transcritical refrigeration system to improve the system performance by recovering some expansion work and reduce power consumption. The ejector-supported system was compared with the parallel compression concept as the baseline system and carried out at different pressure lift and exit gas cooler properties. The result indicated a COP and exergy efficiency improvement up to 2.05% and 1.92% for the set conditions respectively, while the COP could be improved to the highest of 11.22% when the system cooling load is at minimum. Moreover, the ejector played a vital role in the system input power, where up to 3.46% of the energy consumption was reduced at subcritical heat rejection conditions. Operating the system with an ejector at a lower cooling capacity allows a further 18% reduction in overall power consumption. In addition, the exergy analysis revealed a noticeable lack of total system exergy destruction by deploying the ejector in parallel with the highpressure valve, which recovered 21% of the expansion work and saved 46% of the HPV exergy losses. Furthermore, the result exhibited a maximum system exergy loss of 7.8% at the set condition and a maximum of 13.2% total system exergy destruction rate recovered by the ejector, which depends on the cooling load.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Performance optimization of two-stage compressor system using transcritical R744
    Elbel, S.
    Hrnjak, P.
    [J]. INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS 2019, 2019, 604
  • [42] Advanced exergy analysis of a R744 booster refrigeration system with parallel compression
    Gullo, Paride
    Elmegaard, Brian
    Cortella, Giovanni
    [J]. ENERGY, 2016, 107 : 562 - 571
  • [43] Studies on a transcritical R744 based summer air-conditioning unit: Impact of refrigerant charge on system performance
    Hazarika, Mihir M.
    Ramgopal, Maddali
    Bhattacharyya, Souvik
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 89 : 22 - 39
  • [44] Experimental and numerical study on the R744 ejector with a suction nozzle bypass
    Bodys, Jakub
    Smolka, Jacek
    Palacz, Michal
    Haida, Michal
    Banasiak, Krzysztof
    Nowak, Andrzej J.
    [J]. APPLIED THERMAL ENGINEERING, 2021, 194
  • [45] Performance Investigation of a Multi-Ejector R744 Heat Pump
    Singh, Simarpreet
    Reddy, Amshith
    Prakash, Maiya P.
    Banasiak, Krzysztof
    Hafner, Armin
    Neksa, Petter
    [J]. 13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 839 - 846
  • [46] Performance Analysis of an R744 Supermarket Refrigeration System Integrated with an Organic Rankine Cycle
    Sengupta, Ayan
    Gullo, Paride
    Dasgupta, Mani Sankar
    Khorshidi, Vahid
    [J]. ENERGIES, 2023, 16 (22)
  • [47] Analysis of an R744 typical booster configuration, an R744 parallel-compressor booster configuration and an R717/R744 cascade refrigeration system for retail food applications. Part 1: Thermodynamic analysis
    Amaris, Carlos
    Tsamos, Konstantinos M.
    Tassou, Savvas A.
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND RESOURCE USE IN FOOD CHAINS INCLUDING WORKSHOP ON ENERGY RECOVERY CONVERSION AND MANAGEMENT;ICSEF 2018, 2019, 161 : 259 - 267
  • [48] Recent Advances in Transcritical CO2 (R744) Heat Pump System: A Review
    Rony, Rajib Uddin
    Yang, Huojun
    Krishnan, Sumathy
    Song, Jongchul
    [J]. ENERGIES, 2019, 12 (03)
  • [49] FULL SCALE SUPERMARKET LABORATORY R744 EJECTOR SUPPORTED & AC INTEGRATED PARALLEL COMPRESSION UNIT
    Hafner, Armin
    Banasiak, Krzysztof
    [J]. 12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 949 - 956
  • [50] SUCCESSFUL CONVERSION AND VALIDATION OF GLASS DOOR MERCHANDISERS USING TRANSCRITICAL R744
    Elbel, S.
    Fuentes, Y. Padilla
    Bowers, C.
    Hrnjak, P.
    [J]. 11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 421 - 429