The potential impact of the small-scale ejector on the R744 transcritical refrigeration system

被引:11
|
作者
Elbarghthi, Anas F. A. [1 ]
Dvorak, Vaclav [1 ]
Hafner, Armin [2 ]
Banasiak, Krzysztof [3 ]
机构
[1] Tech Univ Liberec, Fac Mech Engn, Dept Appl Mech, Studentska 1402-2, Liberec 46117, Czech Republic
[2] NTNU Dept Energy & Proc Engn, Kolbjorn Hejes Vei 1d, N-7465 Trondheim, Norway
[3] SINTEF Energy Res, N-7465 Trondheim, Norway
关键词
Ejector; CO2; Work recovery; COP; Exergy destruction; Power consumption; Efficiency; CO2; HEAT-PUMP; ADVANCED EXERGY ANALYSIS; MULTI-EJECTOR; SUPERMARKET REFRIGERATION; PERFORMANCE; CYCLE; OPTIMIZATION; PRESSURE; GEOMETRY; DESIGN;
D O I
10.1016/j.enconman.2021.114860
中图分类号
O414.1 [热力学];
学科分类号
摘要
The evident adverse effects of climate change and the consequences of global warming has left an exigent circumstance requiring crucial actions on the applications and technology of refrigeration and air conditioning systems as it concerns its tremendous indirect contributions to greenhouse gas emissions. This field has witnessed steady expansion in recent times. The attendant high-grade energy consumption calls for pragmatic approaches to developing innovative technologies aimed at energy management and finding measures to curb global warming. This current study intends to illustrate the impact of implementing a small-size ejector profile on the R744 transcritical refrigeration system to improve the system performance by recovering some expansion work and reduce power consumption. The ejector-supported system was compared with the parallel compression concept as the baseline system and carried out at different pressure lift and exit gas cooler properties. The result indicated a COP and exergy efficiency improvement up to 2.05% and 1.92% for the set conditions respectively, while the COP could be improved to the highest of 11.22% when the system cooling load is at minimum. Moreover, the ejector played a vital role in the system input power, where up to 3.46% of the energy consumption was reduced at subcritical heat rejection conditions. Operating the system with an ejector at a lower cooling capacity allows a further 18% reduction in overall power consumption. In addition, the exergy analysis revealed a noticeable lack of total system exergy destruction by deploying the ejector in parallel with the highpressure valve, which recovered 21% of the expansion work and saved 46% of the HPV exergy losses. Furthermore, the result exhibited a maximum system exergy loss of 7.8% at the set condition and a maximum of 13.2% total system exergy destruction rate recovered by the ejector, which depends on the cooling load.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] THE PERFORMANCE EVALUATION OF R744 TRANSCRITICAL EJECTOR AND R290/R744 CASCADE REFRIGERATION SYSTEMS FOR TURKEY
    Yilmaz, Deniz
    Yilmaz, Baris
    Mancuhan, Ebru
    [J]. THERMAL SCIENCE, 2019, 23 (06): : 4031 - 4041
  • [2] An experimental study of an ejector-boosted transcritical R744 refrigeration system including an exergy analysis
    Elbarghthi, Anas F. A.
    Hafner, Armin
    Banasiak, Krzysztof
    Dvorak, Vaclav
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 238
  • [3] APPLICATION OF VORTEX CONTROL TO A TRANSCRITICAL R744 EJECTOR CYCLE
    Zhu, Jingwei
    Elbel, Stefan
    [J]. 5TH IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2018, : 53 - 61
  • [4] THERMODYNAMIC PERFORMANCE OF THE TRANSCRITICAL REFRIGERATION CYCLE WITH EJECTOR EXPANSION FOR R744, R170, AND R41
    Atmaca, Ayse Ugurcan
    Erek, Aytunc
    Ekren, Orhan
    Coban, Mustafa Turhan
    [J]. ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2018, 38 (02) : 111 - 127
  • [5] Simulation and optimization of a R744 two- temperature supermarket refrigeration system with an ejector
    Huang, Zhuo
    Zhao, Hongxia
    Yu, Zeting
    Han, Jitian
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 90 : 73 - 82
  • [6] NUMERICAL INVESTIGATION OF AN R744 LIQUID EJECTOR FOR SUPERMARKET REFRIGERATION SYSTEMS
    Haida, Michal
    Smolka, Jacek
    Palacz, Michal
    Bodys, Jakub
    Nowak, Andrzej J.
    Bulinski, Zbigniew
    Fic, Adam
    Banasiak, Krzysztof
    Hafner, Armin
    [J]. THERMAL SCIENCE, 2016, 20 (04): : 1259 - 1269
  • [7] Comprehensive experimental performance study on a small-capacity transcritical R744 vapour-compression refrigeration unit equipped with an innovative ejector
    Gullo, Paride
    Birkelund, Michael
    Kriezi, Ekaterini E.
    Kaern, Martin Ryhl
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 152 : 192 - 203
  • [8] Performance evaluation of an ejector based transcritical R-744 refrigeration system with evaporative gascooler
    Surwase, Sushil Ashok
    Singh, Simarpreet
    Maiya, M. P.
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 39
  • [9] R744 MULTI EJECTOR DEVELOPMENT
    Kriezi, Ekaterini E.
    Fredslund, Kristian
    Banasiak, Krzysztof
    Hafner, Armin
    [J]. 12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 650 - 657
  • [10] VORTEX CONTROL FOR MOTIVE FLOW RATE MODULATION OF TRANSCRITICAL R744 EJECTOR SYSTEMS
    Zhu, Jingwei
    Elbel, Stefan
    [J]. 13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 263 - 270