Model-Based Process Challenge of an Industrial Ion-Exchange Chromatography Step

被引:39
|
作者
Westerberg, Karin [1 ]
Hansen, Ernst Broberg [2 ]
Degerman, Marcus [3 ]
Hansen, Thomas Budde [3 ]
Nilsson, Bernt [1 ]
机构
[1] Lund Univ, Dept Chem Engn, SE-22100 Lund, Sweden
[2] Novo Nordisk AS, DK-2880 Bagsvaerd, Denmark
[3] Novo Nordisk AS, DK-2820 Gentofte, Denmark
基金
瑞典研究理事会;
关键词
Chromatography; Process modeling; Quality by design; Robustness; Sensitivity analysis; SENSITIVITY-ANALYSIS; PREPARATIVE CHROMATOGRAPHY; ROBUSTNESS ANALYSIS; DESIGN; QUALITY; OPTIMIZATION; PURIFICATION; UNCERTAINTY;
D O I
10.1002/ceat.201000560
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The separation of one weakly and one strongly binding impurity from a therapeutic protein by ion-exchange chromatography was studied with a mechanistic model. The effect of disturbances in eight potentially critical process parameters on two critical quality attributes was evaluated. It was found that the outgoing concentration of the weakly binding impurity was only affected by the ingoing concentration of this impurity, while the target product purity was affected by the amounts of buffer and acid used to prepare the elution buffers and the protein concentration and purity of the feed. Full factor analysis of these parameters showed that there were interaction effects between the parameters due to the pH dependence of the chromatographic separation. Sampling-based robustness analysis estimated the probability of batch failure to be above 1?%. The model improved the analysis as it was possible to study the effects of more process parameters and their interactions than would have been possible in an experimental study.
引用
收藏
页码:183 / 190
页数:8
相关论文
共 50 条
  • [21] MODEL FOR ION-EXCHANGE EQUILIBRIA OF MACROMOLECULES IN PREPARATIVE CHROMATOGRAPHY
    LI, YL
    PINTO, NG
    JOURNAL OF CHROMATOGRAPHY A, 1995, 702 (1-2) : 113 - 123
  • [22] Purifying the Sendai virus in one step using ion-exchange chromatography
    Eveleth, J
    Quaranto, L
    Giri, L
    Dasarathy, Y
    BIOPHARM-THE APPLIED TECHNOLOGIES OF BIOPHARMACEUTICAL DEVELOPMENT, 2000, 13 (01): : 40 - 43
  • [23] APPARATUS FOR ION-EXCHANGE CHROMATOGRAPHY
    BAKER, RWR
    BIOCHEMICAL JOURNAL, 1957, 67 : P33 - P33
  • [24] ION-EXCHANGE CHROMATOGRAPHY IN ALCOHOL
    CARROLL, KK
    NATURE, 1955, 176 (4478) : 398 - 400
  • [25] ELECTROMODULATED ION-EXCHANGE CHROMATOGRAPHY
    GHATAKROY, AR
    MARTIN, CR
    ANALYTICAL CHEMISTRY, 1986, 58 (07) : 1574 - 1575
  • [26] ISOELECTRIC ION-EXCHANGE CHROMATOGRAPHY
    KLINE, MH
    CALLAHAN, DMP
    SALVUCCI, TJ
    JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION, 1978, 78 (02): : 142 - 142
  • [27] SUPERFICIAL ION-EXCHANGE CHROMATOGRAPHY
    PARRISH, JR
    NATURE, 1965, 207 (4995) : 402 - &
  • [28] DEVELOPMENTS IN ION-EXCHANGE CHROMATOGRAPHY
    BARNES, N
    AMERICAN LABORATORY, 1993, 25 (16) : BB52 - &
  • [29] Understanding Ion-Exchange Chromatography
    不详
    LC GC NORTH AMERICA, 2012, 30 (08) : 686 - 686
  • [30] Improved purification process of β- and α-trypsin isoforms by ion-exchange chromatography
    Costa Santos, Alexandre Martins
    de Oliveira, Jamil Silvano
    Bittar, Eustaquio Resende
    da Silva, Anderson Lourenco
    dos Mares Guia, Marcos Luiz
    Bemquerer, Marcelo Porto
    Santoro, Marcelo Matos
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2008, 51 (04) : 711 - 721