OCT angiography, RNFL and the visual field at different values of intraocular pressure

被引:7
|
作者
Kral, Jakub [1 ]
Lestak, Jan [1 ,3 ]
Nutterova, Elena [2 ]
机构
[1] Czech Tech Univ, Fac Biomed Engn, Prague, Czech Republic
[2] Ophthalmol Clin JL, Kladno, Prague, Czech Republic
[3] Czech Tech Univ, Fac Biomed Engn, Nam Sitna 3105, Kladno, Prague, Czech Republic
关键词
intraocular pressure; Optical Coherence Tomography angiography; vessel density; retinal nerve fiber layer; overall defect of visual field; COHERENCE TOMOGRAPHY ANGIOGRAPHY; NERVE-FIBER LAYER; RETINAL GANGLION-CELLS; VESSEL DENSITY; OPTICAL MICROANGIOGRAPHY; DIAGNOSTIC ABILITY; GLAUCOMA; DEGENERATION; CAPILLARIES; SHRINKAGE;
D O I
10.3892/br.2022.1519
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aim of the present study was to investigate the relationship between intraocular pressure (IOP), vessel density (VD), retinal nerve fiber layer (RNFL) parameters and overall defect (OD) of the visual field in eyes where antiglaucoma treatment had not yet been initiated. A total of 61 subjects (122 eyes) who had an IOP of >20 mmHg on several occasions, in at least one eye, in routine outpatient care were included. These were subjects who had never been treated for hypertension glaucoma. The cohort was divided into four subgroups. In the first group, there were 18 eyes with an IOP value of <20 mmHg. In the second group, there were 39 eyes with IOP values of 20-22 mmHg. The third group consisted of 32 eyes with IOP values of 22-24 mmHg and the final group consisted of 33 eyes with IOP values of >24 mmHg. The IOP results were compared with VD, RNFL and OD using Pearson's correlation coefficient to assess the relationship between the selected parameters. RNFL and OD were moderately correlated only in the group of eyes with an IOP value >24 (r=0.48); in the other groups the correlation was very weak. However, changes in visual field were already observed in eyes with IOP 20-22 mmHg (r=-0.27). There was a moderate correlation in eyes with an IOP value >24 mmHg (r=-0.53). The most significant result observed was the relationship between VD and RNFL. In eyes with an IOP value <= 20, a moderate to strong correlation between these parameters was observed. This relationship increased with increasing IOP values up to a very strong correlation in the group with an IOP value >24 mmHg. A moderate to strong dependence between VD and RNFL in eyes with an IOP value <= 20 mmHg was observed, and this dependence was very strongly correlated in the eyes with an IOP value >24 mmHg.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Control values of intraocular pressure in different species: a review of literature
    Bakula, Maja
    Kuzman, Tomislav
    Rados, Milan
    Starcevic, Katarina
    Jurjevic, Ivana
    Mamic, Marija
    Pirkic, Boris
    Klarica, Marijan
    CROATIAN MEDICAL JOURNAL, 2024, 65 (06) : 518 - 529
  • [22] Intraocular Worm Causing a Shadow Artifact on OCT Angiography
    Reddy, Subhakar
    Tyagi, Mudit
    Yadav, Anil Ramesh
    OPHTHALMOLOGY RETINA, 2020, 4 (08): : 800 - 800
  • [23] Intraocular Pressure and Visual Field Damage as Risk Factors for Visual Field Progression in Filtering Surgery
    Cohen, John S.
    Novack, Gary D.
    Zink, Jeffrey M.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2010, 41 (04) : 452 - 458
  • [24] The Effect of Achieving Target Intraocular Pressure on Visual Field Worsening
    Villasana, Gabriel A.
    Bradley, Chris
    Ramulu, Pradeep
    Unberath, Mathias
    Yohannan, Jithin
    OPHTHALMOLOGY, 2022, 129 (01) : 35 - 44
  • [25] Relationship between intraocular pressure and preservation of visual field in glaucoma
    Goldberg, I
    SURVEY OF OPHTHALMOLOGY, 2003, 48 : S3 - S7
  • [26] VISUAL FIELD CHANGES PRODUCED BY ARTIFICIALLY ELEVATED INTRAOCULAR PRESSURE
    SCOTT, AB
    MORRIS, A
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1967, 63 (02) : 308 - &
  • [27] Latent asymmetric intraocular pressure as a predictor of visual field defects
    Hong, Samin
    Kang, Sung Yong
    Ma, Kyoung Tak
    Seong, Gong Je
    Kim, Chan Yun
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (09) : 1211 - 1215
  • [28] Fluctuation of intraocular pressure as a predictor of visual field progression - In reply
    Hong, Samin
    Seong, Gong Je
    Kim, Chan Yun
    Hong, Young Jae
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (08) : 1169 - 1170
  • [29] Acute effects of sildenafil on Humphrey visual field and intraocular pressure
    Ermis S.S.
    Inan U.U.
    Samli M.
    Ozturk F.
    International Ophthalmology, 2004, 25 (2) : 69 - 72
  • [30] Variations in intraocular pressure after visual field examination - Reply
    Recupero, SM
    Contestabile, MT
    Taverniti, L
    Villani, GM
    Recupero, V
    JOURNAL OF GLAUCOMA, 2004, 13 (02)