Effect of the location of broken wire wraps on the failure pressure of prestressed concrete cylinder pipes

被引:39
|
作者
Hajali, Masood [1 ]
Alavinasab, Ali [1 ]
Shdid, Caesar Abi [2 ]
机构
[1] Pure Technol, Branchburg, NJ 08876 USA
[2] Lebanese Amer Univ, Dept Civil Engn, New York, NY 10017 USA
关键词
prestressed concrete cylinder pipes; embedded cylinder pipes; finite element analysis; fluid pressure; numerical analysis; sensitivity analysis; building materials; construction materials; analysis and design methods; prestressed concrete; reinforcement;
D O I
10.1002/suco.201400070
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effect of the location of broken prestressing wire wraps on the overall strength of prestressed concrete cylinder pipes (PCCP) is investigated here. An advanced computational model based on non-linear finite element analysis is used to study three possible locations of broken wire wraps: at the spigot joint, at the bell joint and in the barrel of the pipe. A sensitivity analysis was performed to evaluate the cracking of the concrete core and the yielding of the prestressing wires and steel cylinder with increasing internal pressure and with an increasing number of broken wire wraps. Two classes of 2.44 m embedded cylinder pipe (ECP) were modelled with 5, 35, 70, and 100 wire wrap breaks. The results show that broken wire wraps at the joint, and especially the spigot joint, decrease the overall strength of PCCP more so than those at the bell joint or in the barrel of the pipe. The intensity of this effect increases with increasing internal pressure and with a larger number of broken wire wraps.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [41] A prototype test study on the reinforcement effect of prestressed concrete cylinder pipe with external prestressed steel strands
    Zhao L.
    Dou T.
    Cheng B.
    Xia S.
    Zhang T.
    Bi R.
    Shuili Xuebao/Journal of Hydraulic Engineering, 2019, 50 (07): : 844 - 853
  • [42] Stress corrosion failure of large diameter pressure pipelines of prestressed concrete
    Valiente, A
    ENGINEERING FAILURE ANALYSIS, 2001, 8 (03) : 245 - 261
  • [43] Online monitoring of wire breaks in prestressed concrete cylinder pipe utilising fibre Bragg grating sensors
    Huang, Jun
    Zhou, Zude
    Zhang, Dongsheng
    Yao, Xuande
    Li, Litong
    MEASUREMENT, 2016, 79 : 112 - 118
  • [44] Failure pressure analysis of a nuclear reactor prestressed concrete containment building
    Jimenez, S.
    Cornejo, A.
    Barbu, L. G.
    Barbat, A. H.
    Oller, S.
    ENGINEERING STRUCTURES, 2021, 236
  • [45] USE OF LARGE DIAMETER NON-CYLINDER PRESTRESSED CONCRETE PIPES IN CONSTRUCTION OF FOUL AND SURFACE WATER SEWERS
    BREWER, FJ
    CONCRETE, 1974, 8 (04): : 58 - 58
  • [46] FE model for simulating wire-wrapping during prestressing of an embedded prestressed concrete cylinder pipe
    Xiong, Huan
    Li, Penghui
    Li, Qingbin
    SIMULATION MODELLING PRACTICE AND THEORY, 2010, 18 (05) : 624 - 636
  • [47] Detecting wire breaks in prestressed concrete pipes: an easy-to-install distributed fibre acoustic sensing approach
    Rueda-Garcia, Lisbel
    Tasquer-Val, Daniel
    Calderon-Bofias, Pedro
    Calderon, Pedro A.
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2025, 24 (01): : 295 - 312
  • [48] SIZE EFFECT OF SHEAR FAILURE IN PRESTRESSED CONCRETE BEAMS.
    Bazant, Zdenek P.
    Zhiping Cao
    1600, (83):
  • [49] Mitigating the Risk of Failure during Construction Live Loading on Prestressed Concrete Cylinder Pipe (PCCP)
    Alavinasab, Ali
    Khalili, Ashkan
    Hajali, Masood
    Goorkani, Hamid
    PIPELINES 2019: CONDITION ASSESSMENT, CONSTRUCTION, AND REHABILITATION, 2019, : 486 - 492
  • [50] Experimental Study and Numerical Simulation of Three-Edge Bearing Test of Large Diameter Prestressed Concrete Cylinder Pipes
    Zarghamee, Mehdi S.
    Moharrami, Mohammadreza
    PIPELINES 2018: CONDITION ASSESSMENT, CONSTRUCTION, AND REHABILITATION, 2018, : 776 - 787