A fluorescent immunochromatographic strip test using a quantum dot-antibody probe for rapid and quantitative detection of 1-aminohydantoin in edible animal tissues

被引:25
|
作者
Le, Tao [1 ]
Zhang, Zhihao [1 ]
Wu, Juan [1 ]
Shi, Haixing [1 ]
Cao, Xudong [2 ]
机构
[1] Chongqing Normal Univ, Coll Life Sci, Chongqing 401331, Peoples R China
[2] Univ Ottawa, Dept Chem & Biol Engn, Ottawa, ON K1N 6N5, Canada
基金
中国国家自然科学基金;
关键词
1-Aminohydantoin; Immunochromatographic strip test; Quantum dot; Quantitative detection; Animal tissue; TANDEM MASS-SPECTROMETRY; LINKED-IMMUNOSORBENT-ASSAY; NITROFURANTOIN METABOLITE; RESIDUES; SAMPLES; FOOD; 1-AMINO-HYDANTOIN; SEMICARBAZIDE; FURAZOLIDONE; ANTIBIOTICS;
D O I
10.1007/s00216-017-0756-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, simple, and sensitive fluorescent immunochromatographic strip test (ICST) based on quantum dots (QDs) has been developed to detect 1-aminohydantoin (AHD), a major metabolite of nitrofurantoin in animal tissues. To achieve this, QD-labeled antibody conjugates, which consist of CdSe/ZnS QDs and monoclonal antibodies, were prepared by an activated ester method. Under optimal conditions, with the nitrophenyl derivative of AHD as the target, the ICST had a linear range from 0.1 to 100 ng/mL, with a correlation coefficient of 0.9656 and a 50% inhibitory concentration of 4.51 ng/mL. The limit of detection was 0.14 ng/g, which was below the minimum required performance limit of 1 mu g/kg for AHD established by the European Commission. The recoveries for AHD ranged from 81.5% to 108.2%, with coefficients of variation below 13%, based on intraday and interday analysis. Furthermore, for AHD in real samples, the ICST showed high reliability and high correlation with liquid chromatography-tandem mass spectrometry (correlation coefficient of 0.9916). To the best of our knowledge, this is the first report of a novel and sensitive method based on a fluorescent ICST to detect AHD below the minimum required performance limit. The ICST demonstrated high reliability, and could be ideally suited for rapid, simple, and on-site screening of AHD contamination in animal tissues.
引用
收藏
页码:565 / 572
页数:8
相关论文
共 44 条
  • [1] A fluorescent immunochromatographic strip test using a quantum dot-antibody probe for rapid and quantitative detection of 1-aminohydantoin in edible animal tissues
    Tao Le
    Zhihao Zhang
    Juan Wu
    Haixing Shi
    Xudong Cao
    [J]. Analytical and Bioanalytical Chemistry, 2018, 410 : 565 - 572
  • [2] Rapid detection of brucellosis using a quantum dot-based immunochromatographic test strip
    Li, Guangqiang
    Rong, Zhen
    Wang, Shengqi
    Zhao, Hongyan
    Piao, Dongri
    Yang, Xiaowen
    Tian, Guozhong
    Jiang, Hai
    [J]. PLOS NEGLECTED TROPICAL DISEASES, 2020, 14 (09): : 1 - 12
  • [3] Development of Quantum Dot Submicrobeads-based Fluorescent Immunochromatographic Test Strip for Rapid Detection of Chloramphenicol
    Ding Qiao-Qi
    Li Li
    Fan Wen-Tao
    Lyu Ya-Nan
    Hu Jian-Hua
    Yan Li-Ping
    Song Su-Quan
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (11) : 1686 - 1693
  • [4] Rapid quantitative detection for multiple antibiotics in honey using a quantum dot microsphere immunochromatographic strip
    Li, Yue
    Li, Jiahao
    Huang, Huachuan
    Jian, Dan
    Shan, Yanke
    Wang, Shouyu
    Liu, Fei
    [J]. FOOD CONTROL, 2021, 130
  • [5] Preparation of rapid quantitative immunochromatographic strip for the determination of thiamethoxam based on quantum dot fluorescent microspheres
    Cao, Shujie
    Cao, Hui
    Xu, Fei
    Ye, Tai
    Yuan, Min
    Wu, Xiuxiu
    Yin, Fengqin
    Yu, Jingsong
    Hao, Liling
    [J]. Chinese Journal of Analysis Laboratory, 2023, 42 (05) : 646 - 651
  • [6] A FLuorescent immunochromatographic strip using quantum dots for 3-amino-5-methylmorpholino-2-oxazolidinone (AMOZ) detection in edible animal tissues
    Xie, Yong
    Wu, Juan
    Shi, Haixing
    Le, Tao
    [J]. FOOD AND AGRICULTURAL IMMUNOLOGY, 2019, 30 (01) : 208 - 221
  • [7] A fluorescent immunochromatographic strip test using Quantum Dots for fumonisins detection
    Di Nardo, F.
    Anfossi, L.
    Giovannoli, C.
    Passini, C.
    Goftman, V. V.
    Goryacheva, I. Y.
    Baggiani, C.
    [J]. TALANTA, 2016, 150 : 463 - 468
  • [8] Rapid detection of Campylobacter jejuni using fluorescent microspheres as label for immunochromatographic strip test
    Xu, Di
    Wu, Xiaoli
    Li, Bo
    Li, Peng
    Ming, Xing
    Chen, Tingtao
    Wei, Hua
    Xu, Feng
    [J]. FOOD SCIENCE AND BIOTECHNOLOGY, 2013, 22 (02) : 585 - 591
  • [9] Rapid detection of Campylobacter jejuni using fluorescent microspheres as label for immunochromatographic strip test
    Di Xu
    Xiaoli Wu
    Bo Li
    Peng Li
    Xing Ming
    Tingtao Chen
    Hua Wei
    Feng Xu
    [J]. Food Science and Biotechnology, 2013, 22 : 585 - 591
  • [10] Quantum-dot Submicrobead-Based Immunochromatographic Strip for Rapid and Quantitative Detection of Plasmodium Falciparum
    Duan Hong
    Chen Xue-Lan
    Jiang Hu
    Shen Jun
    Dong Sheng-Ming
    Xiong Yong-Hua
    Wang, Andrew
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (03) : 338 - 343