共 50 条
Rapid detection of Campylobacter jejuni using fluorescent microspheres as label for immunochromatographic strip test
被引:0
|作者:
Di Xu
Xiaoli Wu
Bo Li
Peng Li
Xing Ming
Tingtao Chen
Hua Wei
Feng Xu
机构:
[1] Nanchang University,State Key Laboratory of Food Science and Technology
[2] JiangXi University of Traditional Chinese Medicine,undefined
来源:
关键词:
protein PEB1;
fluorescent microsphere;
polyclonal antibody;
immunochromatographic strip test;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
Campylobacter jejuni is a worldwide foodborne pathogen recognized as a leading cause of human gastrointestinal enteritis. A rapid, sensitive, and specific method is required to monitor food and water in cases of contamination by this pathogen. This report presents a novel immunochromatographic test (ICT) using fluorescent microspheres labeled with polyclonal antibodies of C. jejuni as the capture reagent dispensed onto the conjugate pad. Polyclonal antibodies against the outer membrane protein PEB1 of C. jejuni were used as the detective reagent at the test line, whereas the goat anti-rabbit IgG was used on the control line. PEB1 was obtained by gene cloning and expression to prepare its antibody. In this study, a simple and rapid ICT is reported for detecting C. jejuni for the first time with a detection limit of 106 CFU/ mL.
引用
收藏
页码:585 / 591
页数:6
相关论文