Helical CT angiography in evaluation of live kidney donors

被引:50
|
作者
Patil, UD
Ragavan, A
Nadaraj
Murthy, K
Shankar, R
Bastani, B [1 ]
Ballal, SH
机构
[1] St Louis Univ, Sch Med, Div Nephrol, St Louis, MO 63110 USA
[2] Manipal Hosp, Div Nephrol, Bangalore, Karnataka, India
[3] Manipal Hosp, Div Radiol, Bangalore, Karnataka, India
[4] St Louis Univ, Sch Med, Div Radiol, St Louis, MO 63110 USA
关键词
donor evaluation; helical CT scan; renal angiography; transplantation;
D O I
10.1093/ndt/16.9.1900
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Live kidney donor evaluation mandates anatomical and functional assessment of the donor kidney. Helical computed tomography (CT) with advanced 3-D techniques provides detailed description of the vascular, parenchymal, and collecting system. Methods. We compared the accuracy of helical CT angiography with intra-operative findings in the evaluation of 102 live kidney donors. Results. Identification of vascular anomalies was best on direct viewing of the axial images using interactive scrolling through the images and cine-loop paging. In 204 kidneys evaluated, a single renal artery was present in 74.5% and a single renal vein in 87.5%. Multiple renal arteries were more common on the left side (31%) vs the right side (20%). Early branching of the arteries was seen with equal frequency (approximate to 10%) on either side. Multiple renal veins were more often on the right side (20%) vs the left side (5%), and one patient was found to have double inferior vena cava. CT angiographic, findings were concordant with the intra-operative findings in 97% of the cases, missing a small renal vein, an accessory artery that was visualized in retrospect, and a very early branch that was read as accessory artery. CT also revealed cortical cysts (four cases), duplex collecting system (two cases), hydronephrosis (one case), renal stone (one; case), and liver haemangioma (two cases). Conclusion. CT angiography is highly accurate for detecting vascular anomalies, and providing anatomical information. It may serve as the primary tool for donor evaluation.
引用
收藏
页码:1900 / 1904
页数:5
相关论文
共 50 条
  • [31] Usefulness of helical CT angiography in the evaluation of renal artery stenosis
    Tovar, JL
    Sebastiá, MC
    Moreira, M
    Perelló, M
    Castell, J
    Valenzuela, H
    Segarra, A
    [J]. JOURNAL OF HYPERTENSION, 1998, 16 : S193 - S193
  • [32] Magnetic resonance angiography for preoperative evaluation of potential kidney donors
    Rajab, A
    Khabiri, H
    Pelletier, RP
    Henry, ML
    Akin, B
    Elkhammas, E
    Bumgardner, GL
    Ferguson, RM
    [J]. JOURNAL OF SURGICAL RESEARCH, 2004, 120 (02) : 195 - 200
  • [33] EVALUATION OF POTENTIAL KIDNEY DONORS USING DIGITAL SUBTRACTION ANGIOGRAPHY
    SHOKEIR, AA
    ELDIASTY, TA
    SHAABAN, AA
    ELKENAWEY, M
    ERAKY, T
    GHONEIM, MA
    [J]. TRANSPLANTATION PROCEEDINGS, 1993, 25 (03) : 2272 - 2273
  • [34] CT angiography versus conventional digital angiography in preoperative assessment for Chinese living kidney donors
    Yap, Desmond Yat Hin
    Chu, Ferdinand Siu Kay
    Chu, Sai Man
    Tam, Po Chor
    Tam, Sidney
    Chan, Tak Mao
    Lai, Kar Neng
    Tang, Sydney Chi Wai
    [J]. JOURNAL OF NEPHROLOGY, 2010, 23 (06) : 711 - 716
  • [35] PREOPERATIVE EVALUATION OF POTENTIAL RENAL DONORS WITH SPIRAL CT ANGIOGRAPHY
    RYOO, JW
    CHUNG, JW
    PARK, JH
    YEON, KM
    HAN, MC
    [J]. RADIOLOGY, 1995, 197 : 214 - 214
  • [36] Comparison of CT and MR angiography for evaluation of living renal donors
    Moritz, M
    Halpern, E
    Mitchell, D
    Wechsler, R
    Outwater, E
    Radomski, J
    Wilson, G
    Armenti, V
    [J]. TRANSPLANTATION PROCEEDINGS, 2001, 33 (1-2) : 831 - 832
  • [37] EVALUATION OF CEREBRAL ANEURYSMS WITH HELICAL CT - CORRELATION WITH CONVENTIONAL ANGIOGRAPHY AND MR-ANGIOGRAPHY
    SCHWARTZ, RB
    TICE, HM
    HOOTEN, SM
    HSU, LG
    STIEG, PE
    [J]. RADIOLOGY, 1994, 192 (03) : 717 - 722
  • [38] DIGITAL SUBTRACTION ANGIOGRAPHY IN POTENTIAL LIVE-KIDNEY DONORS - A STUDY OF 1000 CASES
    SHOKEIR, AA
    ELDIASTY, TA
    NABEEH, A
    SHAABAN, AA
    ELKENAWY, M
    WAFA, EW
    GHONEIM, MA
    [J]. ABDOMINAL IMAGING, 1994, 19 (05): : 461 - 465
  • [39] Vascular anatomy of live kidney donors: Important but not optimally predicted by mri and subtraction angiography
    Kok, Niels F.
    Wentink, Noor
    Hunink, Myriam G.
    Alwayn, Ian P.
    Tran, Khe T.
    Welmar, Willem
    IJzermans, Jan N.
    [J]. TRANSPLANT INTERNATIONAL, 2007, 20 : 104 - 104
  • [40] Kidney donors live longer
    FehrmanEkholm, I
    Elinder, CG
    Stenbeck, M
    Tyden, G
    Groth, CG
    [J]. TRANSPLANTATION, 1997, 64 (07) : 976 - 978