High-Quality T2-Weighted 4-Dimensional Magnetic Resonance Imaging for Radiation Therapy Applications

被引:31
|
作者
Du, Dongsu [1 ]
Caruthers, Shelton D. [2 ]
Glide-Hurst, Carri [3 ]
Low, Daniel A. [4 ]
Li, H. Harold [1 ]
Mutic, Sasa [1 ]
Hu, Yanle [1 ,5 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO USA
[2] Philips Healthcare, Cleveland, OH USA
[3] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI USA
[4] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90024 USA
[5] Mayo Clin Arizona, Dept Radiat Oncol, Phoenix, AZ 85054 USA
基金
美国国家卫生研究院;
关键词
BREATH-HOLD TECHNIQUE; TUMOR MOTION; RESPIRATORY SURROGATE; COMPUTED-TOMOGRAPHY; GATED RADIOTHERAPY; ORGAN MOTION; LUNG-TUMORS; REGISTRATION; 4D-CT; LIVER;
D O I
10.1016/j.ijrobp.2015.01.035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study was to improve triggering efficiency of the prospective respiratory amplitude-triggered 4-dimensional magnetic resonance imaging (4DMRI) method and to develop a 4DMRI imaging protocol that could offer T2 weighting for better tumor visualization, good spatial coverage and spatial resolution, and respiratory motion sampling within a reasonable amount of time for radiation therapy applications. Methods and Materials: The respiratory state splitting (RSS) and multi-shot acquisition (MSA) methods were analytically compared and validated in a simulation study by using the respiratory signals from 10 healthy human subjects. The RSS method was more effective in improving triggering efficiency. It was implemented in prospective respiratory amplitude-triggered 4DMRI. 4DMRI image datasets were acquired from 5 healthy human subjects. Liver motion was estimated using the acquired 4DMRI image datasets. Results: The simulation study showed the RSS method was more effective for improving triggering efficiency than the MSA method. The average reductions in 4DMRI acquisition times were 36% and 10% for the RSS and MSA methods, respectively. The human subject study showed that T2-weighted 4DMRI with 10 respiratory states, 60 slices at a spatial resolution of 1.5 x 1.5 x 3.0 mm 3 could be acquired in 9 to 18 minutes, depending on the individual's breath pattern. Based on the acquired 4DMRI image datasets, the ranges of peak-to-peak liver displacements among 5 human subjects were 9.0 to 12.9 mm, 2.5 to 3.9 mm, and 0.5 to 2.3 mm in superior-inferior, anterior-posterior, and left-right directions, respectively. Conclusions: We demonstrated that with the RSS method, it was feasible to acquire high-quality T2-weighted 4DMRI within a reasonable amount of time for radiation therapy applications. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:430 / 437
页数:8
相关论文
共 50 条
  • [21] 4-Dimensional Magnetic Resonance Imaging of the Levoatriocardinal Vein
    Gabbour, Maya
    Markl, Michael
    Robinson, Joshua D.
    Rigsby, Cynthia K.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (14) : 1291 - 1291
  • [22] Diagnosis of symptomatic disc by magnetic resonance imaging: T2-weighted and gadolinium-DTPA-enhanced T1-weighted magnetic resonance imaging
    Yoshida, H
    Fujiwara, A
    Tamai, K
    Kobayashi, N
    Saiki, K
    Saotome, K
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2002, 15 (03): : 193 - 198
  • [23] Hybrid Nanotrimers for Dual T1 and T2-Weighted Magnetic Resonance Imaging
    Cheng, Kai
    Yang, Meng
    Zhang, Ruiping
    Qin, Chunxia
    Su, Xinhui
    Cheng, Zhen
    [J]. ACS NANO, 2014, 8 (10) : 9884 - 9896
  • [24] T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning
    Freedman, Joshua N.
    Collins, David J.
    Bainbridge, Hannah
    Rank, Christopher M.
    Nill, Simeon
    Kachelrie, Marc
    Oelfke, Uwe
    Leach, Martin O.
    Wetscherek, Andreas
    [J]. INVESTIGATIVE RADIOLOGY, 2017, 52 (10) : 563 - 573
  • [25] Measuring Muscle Activity in Sprinters Using T2-Weighted Magnetic Resonance Imaging
    Yoshimoto, Takaya
    Chiba, Yoshihiro
    Ohnuma, Hayato
    Yanaka, Takuya
    Sugisaki, Norihide
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2022, 17 (05) : 774 - 779
  • [26] SIGNS OF PATELLAR CHONDROMALACIA ON SAGITTAL T2-WEIGHTED MAGNETIC-RESONANCE-IMAGING
    DESMET, AA
    MONU, JUV
    FISHER, DR
    KEENE, JS
    GRAF, BK
    [J]. SKELETAL RADIOLOGY, 1992, 21 (02) : 103 - 105
  • [27] High-resolution T2-weighted abdominal magnetic resonance imaging using respiratory triggering: Impact of butylscopolamine on image quality
    Wagner, M.
    Klessen, C.
    Rief, M.
    Elgeti, T.
    Taupitz, M.
    Hamm, B.
    Asbach, P.
    [J]. ACTA RADIOLOGICA, 2008, 49 (04) : 376 - 382
  • [28] Ultrasmall Superparamagnetic Iron Oxide Nanoparticle for T2-Weighted Magnetic Resonance Imaging
    Wang, Yaling
    Xu, Chao
    Chang, Yanan
    Zhao, Lina
    Zhang, Kai
    Zhao, Yuliang
    Gao, Fuping
    Gao, Xueyun
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (34) : 28959 - 28966
  • [29] Toxicity and T2-Weighted Magnetic Resonance Imaging Potentials of Holmium Oxide Nanoparticles
    Atabaev, Timur Sh.
    Shin, Yong Cheol
    Song, Su-Jin
    Han, Dong-Wook
    Nguyen Hoa Hong
    [J]. NANOMATERIALS, 2017, 7 (08):
  • [30] An efficient model to guide prospective T2-weighted 4D magnetic resonance imaging acquisition
    Du, Dongsu
    Mutic, Sasa
    Li, H. Harold
    Hu, Yanle
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : 2453 - 2462