Occult traumatic pneumothorax - Diagnostic accuracy of lung ultrasonography in the emergency department

被引:257
|
作者
Soldati, Gino [1 ]
Testa, Americo [2 ]
Sher, Sara [3 ]
Pignataro, Giulia [2 ]
La Sala, Monica [2 ]
Silveri, Nicolo Gentiloni [2 ]
机构
[1] Osped Castelnuovo Garfagnana, Operat Unit Emergency Med, Lucca, Italy
[2] Catholic Univ, Sch Med, Policlin A Gemeli, Dept Emergency Med, Rome, Italy
[3] Osped Maggiore, IRCCS, Dept Anesthesia & Crit Care, Milan, Italy
关键词
chest trauma; lung ultrasonography; occult pneumothorax;
D O I
10.1378/chest.07-1595
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The role of chest ultrasonography (US) in the diagnosis of pneumothorax (PTX) has been established, but how it compares with lung CT scanning in the diagnosis of radiooccult PTX and in the determination of its topographic extension has not yet been completely evaluated. Objective: To determine the diagnostic accuracy of chest US in the emergency department (ED) in the diagnosis of occult PTX in trauma patients and to define its ability to determine PTX extension. Design: An 18-month prospective study. Patients: A total of 109 conscious, spontaneously breathing patients who had been admitted to the ED for chest trauma or polytrauma. Methods: All eligible patients underwent a standard anteroposterior supine chest radiograph (Rx) and a spiral CT lung scan within 1 h of ED admission. Lung US was carried out by an operator who was unaware of the other examination results, both for diagnosis and for the quantitative delimitation of the PTX. Results: Twenty-five traumatic PTXs were detected in the 218 hemithoraxes (109 patients; 2 patients had a bilateral PTX) evaluated by spiral CT scan; of these, only 13 of 25 PTXs (52%) were revealed by chest Rx (sensitivity, 52%; specificity, 100%), while 23 of 25 PTXs (92%) were identified by lung US with one false-positive result (sensitivity, 92%; specificity, 99.4%). In 20 of 25 cases, there was agreement on the extension of the PTX between CT lung scan and lung US with a mean difference of 1.9 cm (range, 0 to 4.5 cm) in the localization of retroparietal air extension; chest Rx was not able to give quantitative results. Conclusions: Lung US scans carried out in the ED detect occult PTX and its extension with an accuracy that is almost as high as the reference standard (CT scanning).
引用
收藏
页码:204 / 211
页数:8
相关论文
共 50 条
  • [31] OCCULT BACTEREMIA IN THE EMERGENCY DEPARTMENT
    CROCKER, PJ
    [J]. ANNALS OF EMERGENCY MEDICINE, 1984, 13 (01) : 45 - 48
  • [32] Traumatic occult pneumothorax-A UK perspective
    Hudson, A. L.
    [J]. RESUSCITATION, 2011, 82 (05) : 639 - 639
  • [33] Use of lung ultrasonography in the detection of pneumothorax among medical students and emergency physician
    UAP Flato
    HP Guimarães
    G Petisco
    F Bezerra
    AB Cavalcante
    O Berwanguer
    [J]. Critical Care, 15 (Suppl 2):
  • [34] Diagnostic accuracy of radiographers' red dot usage in the emergency department
    O'Leary, Mary Beth
    England, Andrew
    Curran, Grainne
    Flynn, Katie
    Ryan, Marie
    Thompson, John
    Albeshan, Salman
    Alashban, Yazeed
    Mcentee, Mark F.
    [J]. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (01)
  • [35] Diagnostic Accuracy of Focused Assessment With Sonography for Trauma in the Emergency Department
    Ala, Ali Reza
    Pouraghaei, Mahboub
    Vahdati, Samad Shams
    Taghizadieh, Ali
    Moharamzadeh, Payman
    Arjmandi, Houri
    [J]. TRAUMA MONTHLY, 2016, 21 (04)
  • [36] Diagnostic accuracy of procalcitonin for bacteremia in the emergency department: a systematic review
    Julian-Jimenez, Agustin
    Eduardo Garcia, Dario
    Merinos-Sanchez, Graciela
    Garcia de Guadiana-Romualdo, Luis
    Gonzalez del Castillo, Juan
    [J]. REVISTA ESPANOLA DE QUIMIOTERAPIA, 2024, 37 (01) : 29 - 42
  • [37] Diagnostic Accuracy of CD64 for Sepsis in Emergency Department
    Dal Ponte, Silvana Teixeira
    Alegretti, Ana Paula
    Pilger, Diogo Andre
    Rezende, Gabriela Petitot
    Andrioli, Giordanna
    Ludwig, Helena Cocolichio
    Diogo, Luciano
    Goldani, Luciano Zubaran
    Loreto, Melina
    Machado, Pauline Simas
    Seligman, Renato
    [J]. JOURNAL OF GLOBAL INFECTIOUS DISEASES, 2018, 10 (02) : 42 - 46
  • [38] Diagnostic Accuracy and Characteristics of Missed Ischemic Strokes in the Emergency Department
    Arch, Allison E.
    Nystrom, Karin V.
    Coca, Steven
    Wira, Charles R., III
    Schindler, Joseph L.
    [J]. STROKE, 2015, 46
  • [39] Diagnostic accuracy and reproducibility of pleural and lung ultrasound in discriminating cardiogenic causes of acute dyspnea in the Emergency Department
    Cibinel, Gian Alfonso
    Casoli, Giovanna
    Elia, Fabrizio
    Padoan, Monica
    Pivetta, Emanuele
    Lupia, Enrico
    Goffi, Alberto
    [J]. INTERNAL AND EMERGENCY MEDICINE, 2012, 7 (01) : 65 - 70
  • [40] Diagnostic accuracy and reproducibility of pleural and lung ultrasound in discriminating cardiogenic causes of acute dyspnea in the Emergency Department
    Gian Alfonso Cibinel
    Giovanna Casoli
    Fabrizio Elia
    Monica Padoan
    Emanuele Pivetta
    Enrico Lupia
    Alberto Goffi
    [J]. Internal and Emergency Medicine, 2012, 7 : 65 - 70