Design, assembly and operation of polymer electrolyte membrane fuel cell stacks to 1 kWe capacity

被引:53
|
作者
Giddey, S [1 ]
Ciacchi, FT [1 ]
Badwal, SPS [1 ]
机构
[1] CSIRO, Mfg & Infrastruct Technol, Clayton, Vic 3169, Australia
关键词
polymer electrolyte membrane fuel cell; fuel cell stack; distributed energy generation;
D O I
10.1016/j.jpowsour.2003.08.026
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Polymer electrolyte membrane (PEM) fuel cell stacks to 1 kW(e) capacity, with an active area of 225 cm(2) per cell, have been constructed and operated to investigate the fuel quality issues (one of the major barriers for commercialization of this technology), and start/stop, thermal cycling and load following capabilities. The stacks were assembled and tested in stages of 2-, 4-, 8- and 15-cell configurations. This paper describes the design and assembly of the stacks tested, analysis of the results and problems encountered during operation. Though the 1 kW(e) stack showed a large variation in the temperature of the interconnect plates due to uneven cooling, the individual cell voltages were found to be within 86 mV (under full load). The average power produced by each cell for the 1 kWe stack operating on air/H-2 was 67.5 W (300 mW cm(-2)). The stack has undergone more than 40 cold start/shut down thermal cycles in the power output range of 0.6-1 kW, over an accumulated operation of similar to300 h with a small degradation in its performance. The electrical efficiency of the stack varied from 39 to 41%. The recoverable combined heat and power (CHP) efficiency of the stack was 65% without external thermal insulation and 80% with external thermal insulation. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:155 / 165
页数:11
相关论文
共 50 条
  • [1] Investigation of Thermal Influence on the Assembly of Polymer Electrolyte Membrane Fuel Cell Stacks
    Peng, Linfa
    Qiu, Diankai
    Yi, Peiyun
    Lai, Xinmin
    [J]. RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 1509 - +
  • [2] Thermal management of high temperature polymer electrolyte membrane fuel cell stacks in the power range of 1-10 kWe
    Reddy, E. Harikishan
    Jayanti, Sreenivas
    Monder, Dayadeep S.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (35) : 20127 - 20138
  • [3] A versatile polymer electrolyte membrane fuel cell (3 kWe) facility
    Giddey, S
    Ciacchi, FT
    Badwal, SPS
    Zelizko, V
    Edwards, JH
    Duffy, GJ
    [J]. SOLID STATE IONICS, 2002, 152 : 363 - 371
  • [4] Leak diagnosis of polymer electrolyte membrane fuel cell stacks
    Asghari, Saeed
    Fouladi, Bahman
    Masaeli, Naser
    Imani, Bagher Faghih
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (27) : 14980 - 14992
  • [5] Guidelines for stable operation of a polymer electrolyte fuel cell with self-humidifying membrane electrolyte assembly
    Chan, S. H.
    Han, M.
    Jiang, S. P.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2007, 154 (05) : B486 - B493
  • [6] Longevity test results for reformate polymer electrolyte membrane fuel cell stacks
    Scholta, J.
    Pawlik, J.
    Chmielewski, N.
    Joerissen, L.
    [J]. JOURNAL OF POWER SOURCES, 2011, 196 (12) : 5264 - 5271
  • [7] Reduced dimensional computational models of polymer electrolyte membrane fuel cell stacks
    Chang, Paul
    Kim, Gwang-Soo
    Promislow, Keith
    Wetton, Brian
    [J]. JOURNAL OF COMPUTATIONAL PHYSICS, 2007, 223 (02) : 797 - 821
  • [8] A novel design of polymer electrolyte membrane fuel cell
    Alhussan, Khaled
    [J]. FEDSM 2007: PROCEEDINGS OF THE 5TH JOINT ASME/JSME FLUIDS ENGINEERING SUMMER CONFERENCE, VOL 2, PTS A AND B, 2007, : 1427 - 1431
  • [9] Operation Strategies Based on Carbon Corrosion and Lifetime Investigations for High Temperature Polymer Electrolyte Membrane Fuel Cell Stacks
    Kannan, A.
    Kaczerowski, J.
    Kabza, A.
    Scholta, J.
    [J]. FUEL CELLS, 2018, 18 (03) : 287 - 298
  • [10] Mechanical behavior of the membrane during the polymer electrolyte fuel cell operation
    Serincan, Mustafa Fazil
    Pasaogullari, Ugur
    [J]. JOURNAL OF POWER SOURCES, 2011, 196 (03) : 1303 - 1313