Design of an Electrothermally Actuated SU-8 Based Microgripper for Biomedical Applications

被引:0
|
作者
Abbas, Muhammad Zaeem [1 ]
Masood, Muhammad Umar [1 ]
Saleem, Muhammad Mubasher [1 ]
Sheikh, Muhammad Fahad [1 ]
机构
[1] Natl Univ Sci & Technol, Islamabad, Pakistan
关键词
microgripper; electrothermal; cell manipulation;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Micromanipulation has become a significant task in the fields of microelectromechanical systems, cell biology and cell mechanics in past few decades. To study cell mechanics and cell biology, samples are required. In general, these samples are taken with the help of a microgripper, also known as micro-tweezer and micromanipulator. In this paper, a biocompatible microgripper design is presented for single cell manipulation. SU-8 material is selected due to biocompatibility and thermal properties for microgripper design. Electrothermal actuators are used to provide input displacement and force to compliant mechanism. Compliant mechanism include Scott Russell mechanism, Multi-stage Compound Radial Flexure and leverage mechanism, which provide amplification in output displacement at low power. Response of microgripper is close to linear for accurate and intelligent manipulation task. Jaws are designed to grip cells and objects of various shapes and sizes. Results are produced using finite element analysis software, to check the usability of design for biomedical applications. 30 mu m displacement is achieved at low voltage of 50 mV, keeping temperature of gripping jaws at room temperature.
引用
收藏
页码:97 / 102
页数:6
相关论文
共 50 条
  • [21] Modelling and experimental verification of heat dissipation mechanisms in an SU-8 electrothermal microgripper
    Wood, D. (david.wood@durham.ac.uk), 1600, Elsevier B.V., Netherlands (124):
  • [22] Characterization of SU-8 for electrokinetic microfluidic applications
    Sikanen, T
    Tuomikoski, S
    Ketola, RA
    Kostiainen, R
    Franssila, S
    Kotiaho, T
    LAB ON A CHIP, 2005, 5 (08) : 888 - 896
  • [23] Glass/SU-8 microchip for electrokinetic applications
    Lima, Renato Sousa
    Gomes Carneiro Leao, Paulo Augusto
    Monteiro, Alessandra Maffei
    de Oliveira Piazzetta, Maria Helena
    Gobbi, Angelo Luiz
    Mazo, Luiz Henrique
    Carrilho, Emanuel
    ELECTROPHORESIS, 2013, 34 (20-21) : 2996 - 3002
  • [24] Innovative SU-8 Lithography Techniques and Their Applications
    Lee, Jeong Bong
    Choi, Kyung-Hak
    Yoo, Koangki
    MICROMACHINES, 2015, 6 (01) : 1 - 18
  • [25] A novel SU-8 electrothermal microgripper based on the type synthesis of the kinematic chain method and the stiffness matrix method
    Chu, Jinkui
    Zhang, Ran
    Chen, Zhaopeng
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2011, 21 (05)
  • [26] Design and development of SU-8 check microvalve based on MEMS technique
    Geng, Zhao-Xin
    Cui, Da-Fu
    Ma, Xiao-Ling
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2008, 6 (05): : 343 - 348
  • [27] Design for testing SU-8 and PDMS based hybrid glucose sensor
    Patel, Jasbir N.
    Kaminska, Bozena
    Gray, Bonnie L.
    Gates, Byron D.
    2008 IEEE 14TH INTERNATIONAL MIXED-SIGNALS, SENSORS, AND SYSTEMS TEST WORKSHOP, 2008, : 93 - +
  • [28] Removal of SU-8 photoresist for thick film applications
    Dentinger, PM
    Clift, WM
    Goods, SH
    MICROELECTRONIC ENGINEERING, 2002, 61-2 : 993 - 1000
  • [29] Design and test of a microfabricated SU-8 optical scanner
    Wang, WC
    Panergo, R
    HEALTH MONITORING AND SMART NONDESTRUCTIVE EVALUATION OF STRUCTURAL AND BIOLOGICAL SYSTEM III, 2004, 5394 : 280 - 287
  • [30] SU-8 cantilever strain sensor with integrated readout based on a piezoresistive SU-8/carbon black composite
    Gammelgaard, L
    Rasmussen, P
    Calleja, M
    Boisen, A
    Micro Total Analysis Systems 2004, Vol 2, 2005, (297): : 482 - 484