Strength and durability recovery of fire-damaged concrete after post-fire-curing

被引:221
|
作者
Poon, CS [1 ]
Azhar, S [1 ]
Anson, M [1 ]
Wong, YL [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Res Ctr Adv Technol Struct Engn, Hong Kong, Hong Kong, Peoples R China
关键词
high temperature; compressive strength; durability; microstructure; hydration products;
D O I
10.1016/S0008-8846(01)00582-8
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effect of post-fire-curing on the strength and durability recovery of fire-damaged concrete was investigated. Twenty normal- (NSC) and high-strength concrete (HSC) mixes incorporating different pozzolans. were prepared and exposed to elevated temperatures till 800 degreesC. After natural cooling, the specimens were subjected to post-fire-curing in water and in a controlled environment for a total duration of 56 days. Unstressed compressive strength, rapid chloride diffusion, and mercury intrusion porosimetry (MIP) tests were conducted to examine the changes in the macro- and microstructure of the concrete. The test results indicated that the post-fire-curing results in substantial strength and durability recovery and its extent depend upon the types of concrete, exposure temperature, method, and duration of recuring. In one case, the recovered strength was 93% of the original unfired strength. Scanning electron microscopy (SEM) investigations indicated that the recovery was due to a number of rehydration processes that regenerate the calcium-silicate-hydrate (C-S-H). The new rehydration products were smaller in size than the original hydration products and filled the internal cracks, honey combs, and capillaries created during the fire. The surface crack widths were also reduced during the recuring process, and in most cases, they were found within the maximum limits specified by the American Concrete Institute (ACI) building code. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1307 / 1318
页数:12
相关论文
共 50 条
  • [21] Strength recovery of thermally damaged high-performance concrete subjected to post-fire carbonation curing
    Liu, Tiejun
    Wang, Haodong
    Zou, Dujian
    Long, Xu
    Miah, Md Jihad
    Li, Ye
    CEMENT & CONCRETE COMPOSITES, 2023, 143
  • [22] Experimental investigation of the strength of fire-damaged concrete depending on admixture contents
    Chun, Yeonju
    Kwon, Jaesun
    Kim, Jeongwoo
    Son, Heeju
    Heo, Soyoung
    Cho, Suyeon
    Kim, Heesun
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 378
  • [23] Residual response of fire-damaged high-strength concrete beams
    Agrawal, Ankit
    Kodur, Venkatesh
    FIRE AND MATERIALS, 2019, 43 (03) : 310 - 322
  • [24] The Colorimetry Method in Assessing Fire-Damaged Concrete
    Wei, Ya
    Kong, Wei-Kang
    Wan, Cheng
    Wang, Ya-Qiong
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2019, 17 (06) : 282 - 294
  • [25] FIRE-DAMAGED CONCRETE STRUCTURES - REBUILD OR REPAIR
    JAMES, ML
    TIMSON, DJ
    CONCRETE, 1972, 6 (06): : 22 - &
  • [26] GUNITE REPAIRS TO FIRE-DAMAGED CONCRETE STRUCTURES
    GREEN, JK
    LONG, WB
    CONCRETE, 1971, 5 (04): : 118 - &
  • [27] Colorimetry method in assessing fire-damaged concrete
    Wei Y.
    Kong W.-K.
    Wan C.
    Zuo Y.-Z.
    Lu Q.-Z.
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2021, 51 (01): : 233 - 244
  • [28] Repairing a fire-damaged concrete turbine pedestal
    Dorsch, David
    Concrete International, 1991, 13 (06) : 33 - 38
  • [29] Effects of cement dosage and cooling regimes on the compressive strength of concrete. after post-fire-curing from 800 οC
    Li, Lang
    Jia, Pu
    Dong, Jiangfeng
    Shi, Long
    Zhang, Guomin
    Wang, Qingyuan
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 142 : 208 - 220
  • [30] Repair of fire-damaged reinforced concrete columns
    Lin, Chien-Hung
    Chen, Shun-Tyan
    Yang, Chen-An
    ACI Materials Journal, 1995, 92 (04) : 406 - 411