Multi-Analyte Sensor Based on Pencil Graphite Electrode for Riboflavin and Pyridoxine Determination

被引:9
|
作者
Buleandra, Mihaela [1 ]
Popa, Dana E. [1 ]
Popa, Adrian [1 ]
Codreanu, Nicoleta A. M. [1 ]
David, Iulia G. [1 ]
机构
[1] Univ Bucharest, Fac Chem, Dept Analyt Chem, Bucharest 5, Romania
关键词
riboflavin; pyridoxine; pencil graphite electrode; simultaneous determination; voltammetry; pharmaceuticals; VITAMIN B-2; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL-BEHAVIOR; COMPOSITE ELECTRODE; NANOTUBES;
D O I
10.1149/1945-7111/ac4c77
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Riboflavin (VB2) and pyridoxine (VB6) are two of the eight water-soluble B vitamins that play an essential role and are correlated in normal function of the body. In the present study, cyclic voltammetry demonstrated that in Britton-Robinson buffer (pH 5.00) VB2 undergoes a quasi-reversible electron transfer reaction and the oxidation of VB6 is irreversible, both electrochemical systems being diffusion controlled at the pencil graphite electrode (PGE) surface. Also, a sensitive and selective voltammetric procedure has been developed for the simultaneous determination of the two compounds using PGE and square wave voltammetry (SWV). Two well-defined oxidation peaks with a voltammetric separation of more than 1.10 V were obtained in Britton-Robinson buffer (pH 5.00). The SWV curves exhibited linear responses with riboflavin and pyridoxine concentrations. Thus, for VB2 two linear concentration ranges of 1.00 center dot 10(-7)-5.00 center dot 10(-5 )M and 5.00 center dot 10(-5)-7.50 center dot 10(-4 )M were obtained and in the case of VB6 the linear response was between 2.50 center dot 10(-5 )M and 2.50 center dot 10(-3 )M. The detection limits for VB2 and VB6 were 7.38 center dot 10(-8 )M and 1.10 center dot 10(-5 )M, respectively. The applicability of PGE was successfully proved for simultaneous determination of VB2 and VB6 in pharmaceutical tablets with good accuracy and precision.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Hybrid plasmonic label-free multi-analyte refractive index sensor
    Kishore, K. R.
    Singh, Utkarsh
    Ayyanar, N.
    Raja, Thavasi G.
    Sanathanan, M. S.
    OPTOELECTRONICS LETTERS, 2019, 15 (04) : 269 - 272
  • [42] Nonenzymatic glucose sensor based on disposable pencil graphite electrode modified by copper nanoparticles
    Pourbeyram, Sima
    Mehdizadeh, Khadijeh
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2016, 24 (04) : 894 - 902
  • [43] Soft classification of single samples based on multi-analyte spectra
    Cheung, Nai-Ho
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (12) : 2370 - 2377
  • [44] Electrochemical detection of riboflavin using tin-chitosan modified pencil graphite electrode
    Nagarajan, Sedhu
    Vairamuthu, Raj
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 891
  • [45] Poly (Riboflavin) Modified Pencil Graphite for the Simultaneous Electrochemical Determination of Serotonin and Dopamine
    Krishnan, Rajasree G.
    Saraswathyamma, Beena
    Raj, T. Anjana
    Gopika, M. G.
    INTERNATIONAL CONFERENCE ON TRENDS IN MATERIAL SCIENCE AND INVENTIVE MATERIALS (ICTMIM 2020), 2020, 2259
  • [46] Hybrid plasmonic label-free multi-analyte refractive index sensor
    Kishore K.R.
    Utkarsh Singh
    Ayyanar N.
    Thavasi Raja G.
    Sanathanan M.S.
    Optoelectronics Letters, 2019, 15 (04) : 269 - 272
  • [47] A surfactant enhanced novel pencil graphite and carbon nanotube composite paste material as an effective electrochemical sensor for determination of riboflavin
    Tigari, Girish
    Manjunatha, J. G.
    JOURNAL OF SCIENCE-ADVANCED MATERIALS AND DEVICES, 2020, 5 (01): : 56 - 64
  • [48] Sensitive Electrochemical Determination of Trifluralin at a Disposable Pencil Graphite Electrode
    Gege, Umit
    Karakaya, Serkan
    Dilgin, Yusuf
    ELECTROANALYSIS, 2021, 33 (06) : 1547 - 1556
  • [49] Differential pulse voltammetric determination of eugenol at a pencil graphite electrode
    Saglam, Ozlem
    Dilgin, Didem Giray
    Ertek, Bensu
    Dilgin, Yusuf
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 60 : 156 - 162
  • [50] Sensitive Voltammetric Determination of Niclosamide at a disposable pencil graphite electrode
    Dede, Eda
    Saglam, Ozlem
    Dilgin, Yusuf
    ELECTROCHIMICA ACTA, 2014, 127 : 20 - 26