Simultaneous PET/MR Images Acquired with an RF-Penetrable PET Insert

被引:0
|
作者
Grant, Alexander M.
Lee, Brian J.
Chang, Chen-Ming
Levin, Craig S.
机构
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Simultaneous PET/MRI shows great promise for improved detection and diagnosis of disease. Commercially available whole body combined PET/MRI systems are currently prohibitively expensive, limiting access to the technology. MRI-compatible PET inserts present a lower-cost alternative, adding PET capabilities to existing MRI installations. A brain sized radio-frequency (RF)-penetrable PET insert has been designed for simultaneous operation within MRI systems. This insert takes advantage of electro-optical coupling and battery power to electrically float the PET insert relative to the MRI ground, permitting RF signals to be transmitted and received through small gaps between the PET modules. Non-magnetic silicon photomultipliers are used in conjunction with a compressed sensing signal multiplexing scheme, and optical fibers transmit analog PET detector signals out of the MRI room for decoding, processing, and image reconstruction. Results of the first simultaneous PET/MR imaging studies with the full RF-penetrable PET ring are presented in this work. The PET insert was placed within a 3T whole body MRI system, and tomographic images of a 3D-printed resolution phantom with hot and cold rods of varying sizes were acquired both with only the B-0 field present, and under continuous pulsing from three MR imaging sequences: gradient echo (GRE), fast spin echo (FSE), and echo planar imaging (EPI). The resulting PET images have comparable contrast-to-noise ratios (CNR) under all pulsing conditions, with an average (of all rod types) maximum CNR difference of 14.0% among images. MR images of the resolution phantom were successfully acquired through the RF-penetrable PET shielding using only the built in MR body coil, with mean CNR decreases of 19.5% and 29.8% for GRE and FSE, respectively. These results suggest that simultaneous imaging is possible with the RF-penetrable insert, and show promise for this technology as an alternative to costly integrated PET/MRI scanners.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] SimPET: a Preclinical PET Insert for Simultaneous PET/MR Imaging
    Jeong-Whan Son
    Kyeong Yun Kim
    Ji Yong Park
    Kyuwan Kim
    Yun-Sang Lee
    Guen Bae Ko
    Jae Sung Lee
    Molecular Imaging and Biology, 2020, 22 : 1208 - 1217
  • [22] RF-Transmissive PET Detector Insert for Simultaneous PET/MRI
    Lee, Brian J.
    Grant, Alexander M.
    Chang, Chen-Ming
    Glover, Gary H.
    Levin, Craig S.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [23] Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging
    Ko, Guen Bae
    Kim, Kyeong Yun
    Yoon, Hyun Suk
    Lee, Min Sun
    Son, Jeong-Whan
    Im, Hyung-Jun
    Lee, Jae Sung
    MEDICAL PHYSICS, 2016, 43 (01) : 72 - 83
  • [24] Development of PET insert for simultaneous PET/MR imaging of human brain
    Jiwoong Jung
    Yong Choi
    Jin Ho Jung
    Sangsu Kim
    Ki Chun Im
    Hyun Keong Lim
    Changheun Oh
    HyunWook Park
    Gyuseong Cho
    EJNMMI Physics, 1 (Suppl 1)
  • [25] Performance Study of a Radio-Frequency Field-Penetrable PET Insert for Simultaneous PET/MRI
    Chang, Chen-Ming
    Lee, Brian J.
    Grant, Alexander M.
    Groll, Andrew N.
    Levin, Craig S.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (05) : 422 - 431
  • [26] Characterization of TOF-PET detectors for a second generation radiofrequency-penetrable PET insert for simultaneous PET/MRI
    Dong, Qian
    Lee, Brian J.
    Chang, Chen-Ming
    Sacco, Ilaria
    Watkins, Ronald D.
    Fischer, Peter
    Anaya, Emily
    Levin, Craig S.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [27] Performance simulation of a compact PET insert for simultaneous PET/MR breast imaging
    Liang, Yicheng
    Peng, Hao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 751 : 23 - 30
  • [28] Investigation of RF field Penetrability of a Novel Electrically Floating PET Insert for PET/MR
    Lee, Brian J.
    Grant, Alexander M.
    Chang, Chen-Ming
    Levin, Craig S.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [29] Simultaneously Acquired MR/PET Images Compared with Sequential MR/PET and PET/CT: Alignment Quality
    Brendle, Cornelia B.
    Schmidt, Holger
    Fleischer, Sabrina
    Braeuning, Uli H.
    Pfannenberg, Christina A.
    Schwenzer, Nina F.
    RADIOLOGY, 2013, 268 (01) : 190 - 199
  • [30] PET Insert for PET/MR Brain Imaging
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (07) : 23N - 24N