Simultaneous PET/MRI shows great promise for improved detection and diagnosis of disease. Commercially available whole body combined PET/MRI systems are currently prohibitively expensive, limiting access to the technology. MRI-compatible PET inserts present a lower-cost alternative, adding PET capabilities to existing MRI installations. A brain sized radio-frequency (RF)-penetrable PET insert has been designed for simultaneous operation within MRI systems. This insert takes advantage of electro-optical coupling and battery power to electrically float the PET insert relative to the MRI ground, permitting RF signals to be transmitted and received through small gaps between the PET modules. Non-magnetic silicon photomultipliers are used in conjunction with a compressed sensing signal multiplexing scheme, and optical fibers transmit analog PET detector signals out of the MRI room for decoding, processing, and image reconstruction. Results of the first simultaneous PET/MR imaging studies with the full RF-penetrable PET ring are presented in this work. The PET insert was placed within a 3T whole body MRI system, and tomographic images of a 3D-printed resolution phantom with hot and cold rods of varying sizes were acquired both with only the B-0 field present, and under continuous pulsing from three MR imaging sequences: gradient echo (GRE), fast spin echo (FSE), and echo planar imaging (EPI). The resulting PET images have comparable contrast-to-noise ratios (CNR) under all pulsing conditions, with an average (of all rod types) maximum CNR difference of 14.0% among images. MR images of the resolution phantom were successfully acquired through the RF-penetrable PET shielding using only the built in MR body coil, with mean CNR decreases of 19.5% and 29.8% for GRE and FSE, respectively. These results suggest that simultaneous imaging is possible with the RF-penetrable insert, and show promise for this technology as an alternative to costly integrated PET/MRI scanners.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] RF-Penetrable PET insert for simultaneous PET/MR imaging
    Brian J Lee
    Alexander M Grant
    Chen-Ming Chang
    Craig S Levin
    EJNMMI Physics, 1 (Suppl 1)
  • [2] PET Performance Evaluation of a RF-Penetrable PET Insert for Simultaneous PET/MR Imaging
    Chang, Chen-Ming
    Grant, Alexander M.
    Lee, Brian J.
    Levin, Craig S.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [3] Successful demonstration of simultaneous PET/MR Imaging with a RF-penetrable PET insert
    Brian Lee
    Alexander Grant
    Chen-Ming Chang
    Gary Glover
    Craig Levin
    EJNMMI Physics, 2 (Suppl 1)
  • [4] Motion Correction for Simultaneous PET/MR Brain Imaging Using a RF-Penetrable PET Insert
    Fisher, Jonathan
    Groll, Andrew
    Levin, Craig S.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [5] Performance evaluation of RF coils integrated with an RF-penetrable PET insert for simultaneous PET/MRI
    Lee, Brian J.
    Watkins, Ronald D.
    Lee, Keum Sil
    Chang, Chen-Ming
    Levin, Craig S.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1434 - 1446
  • [6] Performance evaluation of an advanced detector module for an RF-penetrable TOF-PET insert for simultaneous PET/MRI
    Dong, Qian
    Sacco, Ilaria
    Chang, Chen-Ming
    Lee, Brian J.
    Levin, Craig S.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [7] Design and initial results of an RF-penetrable TOF PET insert dedicated for brain PET/MRI
    Chang, Chen-Ming
    Lee, Brian J.
    Sacco, Ilaria
    Watkins, Ronald D.
    Dong, Qian
    Levin, Craig S.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [8] Simultaneous PET/MRI Images Acquired with an RF-Transmissive PET Insert
    Grant, Alexander M.
    Lee, Brian J.
    Chang, Chen-Ming
    Levin, Craig S.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [9] PETcoil: first results from a second-generation RF-penetrable TOF-PET brain insert for simultaneous PET/MRI
    Dong, Qian
    Ullah, Muhammad Nasir
    Innes, Derek
    Watkins, Ronald D.
    Chang, Chen-Ming
    Zou, Sarah J.
    Groll, Andrew
    Sacco, Ilaria
    Chinn, Garry
    Levin, Craig S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (18):
  • [10] Simultaneous PET/MR imaging with a radio frequency- penetrable PET insert
    Grant, Alexander M.
    Lee, Brian J.
    Chang, Chen-Ming
    Levin, Craig S.
    MEDICAL PHYSICS, 2017, 44 (01) : 112 - 120