Evaluation of a low-cost liquid ultrasound test object for detection of transducer artefacts

被引:19
|
作者
King, Deirdre M. [1 ]
Hangiandreou, Nicholas J. [1 ]
Tradup, Donald J. [1 ]
Stekel, Scott F. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 23期
关键词
DOPPLER ULTRASOUND; PHANTOM;
D O I
10.1088/0031-9155/55/23/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Routine quality control of ultrasound scanners and transducers is important for maintaining image quality. Our experience suggests that artefact and uniformity evaluation is the most effective single phantom test for detecting equipment problems. Current methods for assessing ultrasound images for artefacts have important limitations. To overcome these limitations, we have developed a novel, low-cost, liquid phantom with a flexible surface for assessing artefacts. A range of materials were evaluated and the optimal liquid phantom was found to be a water/cornstarch solution contained within a flexible latex balloon. When compared to a rigid tissue-mimicking phantom no deficiencies in overall image appearance or artefact detection for any transducer model was observed for the liquid phantom. With minimal training, reproducible clips were obtained by clinical sonographers with low inter- and intra-operator dependence, for a range of transducers models. The flexible scanning surface of the liquid phantom allows complete rapid coupling of all transducers. Due to its ease of use and low cost this liquid phantom appears superior to rigid phantoms for assessment of non-uniformity artefacts, and should allow clinical practices to perform routine artefact assessments of all ultrasound scanners and transducers.
引用
收藏
页码:N557 / N570
页数:14
相关论文
共 50 条
  • [31] The Evaluation of a Low-Cost Colorimeter for Glucose Detection in Salivary Samples
    Dominguez, Rocio B.
    Orozco, Miguel A.
    Chavez, Giovanny
    Marquez-Lucero, Alfredo
    SENSORS, 2017, 17 (11):
  • [32] Evaluation of a low-cost dryer for a low-cost optical particle counter
    Chacon-Mateos, Miriam
    Laquai, Bernd
    Vogt, Ulrich
    Stubenrauch, Cosima
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2022, 15 (24) : 7395 - 7410
  • [33] LOW-COST SYNCHRONOUS DETECTION
    HANKER, P
    ELECTRONICS WORLD & WIRELESS WORLD, 1992, 98 (1670): : 84 - 85
  • [34] Low-cost detection of lasers
    Benton, David M.
    OPTICAL ENGINEERING, 2017, 56 (11)
  • [35] A Low-Cost Camera-based Transducer Tracking System for Freehand Three-Dimensional Ultrasound
    Baba, Mohammad M.
    Mohamed, Otmane Ait
    Awwad, Falah
    Daoud, Mohammad I.
    2016 14TH IEEE INTERNATIONAL NEW CIRCUITS AND SYSTEMS CONFERENCE (NEWCAS), 2016,
  • [36] Detection of Hydrogen Peroxide in Liquid and Vapors Using Titanium(IV)-Based Test Strips and Low-Cost Hardware
    Hossain, Rayhan
    Dickinson, Jimmy J.
    Apblett, Allen
    Materer, Nicholas F.
    SENSORS, 2022, 22 (17)
  • [37] LOW-COST SOLID OBJECT MODELING FOR WINDOWS
    不详
    MACHINE DESIGN, 1994, 66 (16) : 120 - 120
  • [38] THE EVALUATION OF A NEW LOW-COST TEST PACK FOR BETA-HCG
    HANSSON, LO
    TIAINEN, K
    SWANLJUNG, P
    CLINICAL CHEMISTRY, 1987, 33 (06) : 889 - 889
  • [39] LOW-COST EVALUATION FOR POWERPC
    不详
    ELECTRONICS WORLD & WIRELESS WORLD, 1994, (1702): : 749 - 749
  • [40] Low-cost ultrasound measurement system for accurate detection of container utilization rate
    Gronman, J.
    Rantanen, P.
    Saari, M.
    Sillberg, P.
    Vihervaara, J.
    2018 41ST INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2018, : 878 - 882