Analysis of sewage sludge using an experimental prompt gamma neutron activation analysis (pgnaa) set-up with an am-be source

被引:0
|
作者
Idiri, Z. [1 ]
Redjem, F. [2 ]
Beloudah, N. [2 ]
机构
[1] Ctr Rech Nucl Alger, 02 Bd Frantz Fanon,BP 399, Algiers, Algeria
[2] Univ Sci & Technol Houari Boumediene, Bab Ezzouar, Alger, Algeria
关键词
Sewage sludge; industrial wastewater; PGNAA; WATER;
D O I
10.1142/S2010194516602155
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An experimental PGNAA set-up using a 1 Ci Am-Be source has been developed and used for analysis of bulk sewage sludge samples issued from a wastewater treatment plant situated in an industrial area of Algiers. The sample dimensions were optimized using thermal neutron flux calculations carried out with the MCNP5 Monte Carlo Code. A methodology is then proposed to perform quantitative analysis using the absolute method. For this, average thermal neutron flux inside the sludge samples is deduced using average thermal neutron flux in reference water samples and thermal flux measurements with the aid of a He-3 neutron detector. The average absolute gamma detection efficiency is determined using the prompt gammas emitted by chlorine dissolved in a water sample. The gamma detection efficiency is normalized for sludge samples using gamma attenuation factors calculated with the MCNP5 code for water and sludge. Wet and dehydrated sludge samples were analyzed. Nutritive elements (Ca, N, P, K) and heavy metals elements like Cr and Mn were determined. For some elements, the PGNAA values were compared to those obtained using Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma (ICP) methods. Good agreement is observed between the different values. Heavy element concentrations are very high compared to normal values; this is related to the fact that the wastewater treatment plant is treating not only domestic but also industrial wastewater that is probably rejected by industries without removal of pollutant elements. The detection limits for almost all elements of interest are sufficiently low for the method to be well suited for such analysis.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Feasibility study of prompt gamma neutron activation analysis (PGNAA) of explosives simulants and bulk material using DD/DT neutron generator
    Bishnoi, S.
    Sarkar, P. S.
    Patel, T.
    Adhikari, P. S.
    Sinha, Amar
    INTERNATIONAL CONFERENCE ON RECENT TRENDS IN NUCLEAR PHYSICS-2012 (ICRTNP-2012), 2013, 1524 : 275 - 278
  • [22] PROMPT GAMMA-ACTIVATION-ANALYSIS WITH THE TEXAS COLD NEUTRON SOURCE
    UNLU, K
    RIOSMARTINEZ, C
    WEHRING, BW
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 193 (01): : 145 - 154
  • [23] Stabilization of prompt gamma-ray neutron activation analysis (PGNAA) spectra from NaI detectors
    Metwally, WA
    Gardner, RP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (03): : 518 - 521
  • [24] Experimental gamma coincidence spectra recorded in prompt gamma neutron activation analysis
    Rouaux, Jeremy Roult dit
    Carasco, Cedric
    Loubet, Laurent
    Perot, Bertrand
    Tamagno, Leonie
    Collot, Johann
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (12) : 6577 - 6592
  • [25] Prompt gamma activation analysis using a chopped neutron beam
    G. L. Molná
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 264 : 277 - 281
  • [26] Prompt gamma activation analysis using a chopped neutron beam
    Révay, Z
    Belgya, T
    Szentmiklósi, L
    Molnár, GL
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 264 (02) : 277 - 281
  • [27] Determination of europium content in Li2SiO3(Eu) by neutron activation analysis using Am-Be neutron source
    Naik, Yeshwant
    Tapase, Anant Shamrao
    Mhatre, Amol
    Datrik, Chandrashekhar
    Tawade, Nilesh
    Kumar, Umesh
    Naik, Haladhara
    APPLIED RADIATION AND ISOTOPES, 2016, 118 : 7 - 11
  • [28] A quantitative PGNAA study for use in aqueous solution measurements using Am-Be neutron source and BGO scintillation detector
    Ghal-Eh, N.
    Ahmadi, P.
    Doost-Mohammadi, V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 808 : 123 - 127
  • [29] Efficient set-up for determination of elemental content in liquid samples using neutron activation analysis
    Soliman, Mohamed
    Mohamed, Nader M. A.
    Abd El-Samad, M. A.
    Abdel-Monem, A. M.
    Hamid, Ashraf
    Saad, E. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 295 (01) : 245 - 254
  • [30] Efficient set-up for determination of elemental content in liquid samples using neutron activation analysis
    Mohamed Soliman
    Nader M. A. Mohamed
    M. A. Abd El-Samad
    A. M. Abdel-Monem
    Ashraf Hamid
    E. A. Saad
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 295 : 245 - 254