Outcomes of patients subjected to aortic valve replacement surgery using mechanical or biological prostheses

被引:10
|
作者
de Almeida, Adriana Silveira [1 ,2 ]
Picon, Paulo Dornelles [1 ]
Belmonte Wender, Orlando Carlos [3 ,4 ,5 ]
机构
[1] Univ Fed Rio Grande do Sul, Dept Med Interna, Fac Med, Porto Alegre, RS, Brazil
[2] Hosp Nossa Senhora Conceicao, Grp Hosp Conceicao, Porto Alegre, RS, Brazil
[3] Univ Munique, Alemanha, Brazil
[4] Univ Fed Rio Grande do Sul, Dept Cirurgia, Fac Med, Porto Alegre, RS, Brazil
[5] Hosp Clin Porto Alegre, Serv Cirurgia Cardiovasc, Porto Alegre, RS, Brazil
来源
关键词
Bioprosthesis; Heart Valve Prosthesis Implantation; Aortic Valve; Heart Valve Prosthesis; HEART-VALVE; BIOPROSTHETIC VALVE; HOSPITAL MORTALITY; RISK; GUIDELINES; IMPACT; DETERMINANTS; REOPERATION; MORBIDITY; CHOICE;
D O I
10.5935/1678-9741.20110006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This paper evaluates outcomes in patients subjected to surgery for replacement of the aortic valve using biological or mechanical substitutes, where selection of the type of prosthesis is relevant. Methods: Three hundred and one patients, randomly selected, who had been subjected to aortic valve replacement surgery between 1990 and 2005, with a maximum follow-up period of 20 years. Results: Survival at 5, 10 and 15 years after surgery using mechanical substitute was 83.9%, 75.4% and 60.2% and, for biological substitute, was 89.3%, 70.4% and 58.4%, respectively (P=0.939). Factors associated with death were: age, obesity, pulmonary disease, arrhythmia, bleeding and aortic valve failure. Probability free of reoperation for these patients at 5, 10 and 15 years after surgery using mechanical substitute was 97.9%, 95.8% and 95.8% and, for those using bioprostheses, was 94.6%, 91.0% and 83.3%, respectively (P=0.057). Factors associated with reoperation were: renal failure, prosthesis endocarditis and age. Probability free of bleeding events at 5, 10 and 15 years after surgery using mechanical substitute was 94.5%, 91.7% and 91.7% and, for bioprostheses, was 98.6%, 97.8% and 97.8%, respectively (P=0.047). Factors associated with bleeding events were: renal failure and mechanical prostheses. Conclusions: The authors have concluded that: 1) mortality was statistically similar in the groups; 2) patient characteristics at baseline were a major determinant of late mortality after surgery; 3) there was a tendency toward reoperation in the bioprostheses group; 4) patients using mechanical prosthesis had more bleeding events as time passed; 5) data presented in this paper is in accordance with current literature.
引用
收藏
页码:326 / 337
页数:12
相关论文
共 50 条
  • [1] Biological versus mechanical prostheses for aortic valve replacement
    Rodriguez-Caulo, Emiliano A.
    Blanco-Herrera, Oscar R.
    Berastegui, Elisabet
    Arias-Dachary, Javier
    Souaf-Khalafi, Souhayla
    Parody-Cuerda, Gertrudis
    Laguna, Gregorio
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 165 (02): : 609 - +
  • [2] Totally endoscopic aortic valve replacement with stented biological and mechanical aortic prostheses
    Pitsis, A.
    Tsotsolis, N.
    Nikoloudakis, N.
    Boudoulas, H.
    Boudoulas, K. D.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1977 - 1977
  • [3] Mechanical versus biological prostheses in patients with tricuspid valve replacement
    Carrier, M
    Hebert, Y
    Pellerin, M
    Bouchard, D
    Perrault, LP
    Cartier, R
    Page, P
    Poirier, N
    CIRCULATION, 2002, 106 (19) : 554 - 554
  • [4] Aortic Root Replacement Surgery-A Center Experience with Biological Valve Prostheses
    Salem, Mohamed
    Boehme, Maximilian
    Friedrich, Christine
    Ernst, Markus
    Puehler, Thomas
    Lutter, Georg
    Schoeneich, Felix
    Haneya, Assad
    Cremer, Jochen
    Schoettler, Jan
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (03)
  • [5] Prosthetic Valve Endocarditis After Aortic Valve Replacement: Differences Between Biological and Mechanical Prostheses
    Timmermans, Naomi
    Lam, Ka Yan
    van Straten, Albert
    van't Veer, Marcel
    Soliman-Hamad, Mohamed
    HEART LUNG AND CIRCULATION, 2024, 33 (01): : 130 - 137
  • [6] Safety of Mechanical and Biological Aortic Valve Prostheses in Older Patients REPLY
    Kyto, Ville
    Gunn, Jarmo
    ANNALS OF THORACIC SURGERY, 2022, 113 (01): : 372 - 372
  • [7] Utilization of mechanical prostheses and outcomes of surgical aortic valve replacement at safety net hospitals
    Kim, Samuel T.
    Tran, Zachary
    Xia, Yu
    Dobaria, Vishal
    Ng, Ayesha
    Benharash, Peyman
    SURGERY OPEN SCIENCE, 2022, 9 : 28 - 33
  • [8] Aortic valve replacement with mechanical and biologic prostheses in middle-aged patients
    Carrier, M
    Pellerin, M
    Perrault, LP
    Pagé, P
    Hébert, Y
    Cartier, R
    Dyrda, I
    Pelletier, LC
    ANNALS OF THORACIC SURGERY, 2001, 71 (05): : S253 - S256
  • [9] Aortic valve replacement with mechanical vs. biological prostheses in patients aged 50-69 years
    Glaser, Natalie
    Jackson, Veronica
    Holzmann, Martin J.
    Franco-Cereceda, Anders
    Sartipy, Ulrik
    EUROPEAN HEART JOURNAL, 2016, 37 (34) : 2658 - 2667
  • [10] Circulating microemboli in patients after aortic valve replacement with pulmonary autografts and mechanical valve prostheses
    Notzold, A
    Droste, DW
    Hagedorn, G
    Berndt, S
    Kaps, M
    Graf, B
    Sievers, HH
    CIRCULATION, 1997, 96 (06) : 1843 - 1846