Development of a Novel Flow Cytometry-Based System for White Blood Cell Differential Counts: 10-color LeukoDiff

被引:6
|
作者
Park, Dongjin [1 ]
Chang, Jiyoung [1 ]
Kahng, Jimin [1 ]
Park, Hunhee [2 ]
Jo, Irene [1 ]
Kim, Yonggoo [1 ]
Han, Kyungja [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Lab Med, Seoul, South Korea
[2] Ansan Univ, Dept Clin Lab Sci, Ansan, South Korea
关键词
Flow cytometry; Manual differential count; 10-color LeukoDiff; Blasts; Immature granulocytes; LEUKOPENIC SAMPLES; INFECTION; DIAGNOSIS;
D O I
10.3343/alm.2019.39.2.141
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Flow cytometry (FCM) is commonly used to identify many cell populations. We developed a white blood cell (WBC) differential counting system for detecting abnormal cells using FCM incorporating 10 colors and 11 antibodies in a single tube, called "10-color LeukoDiff," and evaluated its performance. Methods: Ninety-one EDTA-anti-coagulated peripheral blood samples from 76 patients were analyzed using 10-color LeukoDiff. We compared 10 color LeukoDiff results with the results of manual differential count (manual diff). WBCs were classified into 17 cell populations: neutrophils, total lymphocytes, T lymphocytes, B lymphocytes, CD5 and CD19 co-expressing lymphocytes, natural killer cells, total monocytes, 16+ monocytes, eosinophils, immature granulocytes, basophils, myeloblasts, B-blasts, T-blasts, myeloid antigen-positive B-blasts, CD19- plasma cells, and 19+ plasma cells. Results: The correlations between the 10-color LeukoDiff and manual diff results were strong (r>0.9) for mature neutrophils, lymphocytes, eosinophils, immature granulocytes, and blasts and moderate for monocytes and basophils (r=0.86 and 0.74, respectively). There was no discrepancy in blast detection between 10-color LeukoDiff and manual diff results. Furthermore, 10-color LeukoDiff could differentiate the lineage of the blasts and separately count chronic lymphocytic leukemic cells and multiple myeloma cells. Conclusions: The 10-color LeukoDiff provided an accurate and comprehensive WBC differential count. The most important ability of 10-color LeukoDiff is to detect blasts accurately. This system is clinically useful, especially for patients with hematologic diseases, such as acute leukemia, chronic lymphocytic leukemia, and multiple myeloma. Application of this system will improve the development of FCM gating strategy designs.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 50 条
  • [31] Development of a flow cytometry-based plating-free system for strain engineering in industrial fungi
    Yang, Yu-Jing
    Liu, Yin
    Liu, Dan-Dan
    Guo, Wen-Zhu
    Wang, Li-Xian
    Wang, Xing-Ji
    Lv, He-Xin
    Yang, Yang
    Liu, Qian
    Tian, Chao-Guang
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2022, 106 (02) : 713 - 727
  • [32] Practical 10-Color T-Cell Panel for Phenotyping Diverse Populations Using Spectral Flow Cytometry: A Beginner's Guide
    Zargaran, Sina
    Oveisi, Morvarid
    Sun, Chunxiang
    Barbour, Abdelahhad
    Glogauer, Michael
    CURRENT PROTOCOLS, 2024, 4 (03):
  • [33] The use of intracellular dyes to create a multiplexed flow cytometry-based red blood cell phenotyping assay
    Liwski, Robert
    Greenshields, Anna
    Grace, Ian
    Rourke, Craig
    Cheng, Calvino
    Quinn, Jason George
    VOX SANGUINIS, 2024, 119 (07) : 752 - 757
  • [34] A novel flow cytometry-based quantitative monocyte adhesion assay to estimate endothelial cell activation in vitro
    Vincent, Vinnyfred
    Thakkar, Himani
    Verma, Anjali
    Sen, Atanu
    Chandran, Nikhil
    Singh, Archna
    BIOTECHNIQUES, 2020, 68 (06) : 325 - 332
  • [35] Differential blood cell counts obtained using a microchannel based flow cytometer
    Altendorf, E
    Zebert, D
    Holl, M
    Yager, P
    TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 1997, : 531 - 534
  • [36] A Flow Cytometry-Based Whole Blood Natural Killer Cell Cytotoxicity Assay Using Overnight Cytokine Activation
    Kim, Jinho
    Phan, Minh-Trang Thi
    Kweon, SoonHo
    Yu, HongBi
    Park, Jeehun
    Kim, Kyeong-Hee
    Hwang, Ilwoong
    Han, Sangbin
    Kwon, Min-Jung
    Cho, Duck
    FRONTIERS IN IMMUNOLOGY, 2020, 11
  • [37] Assessment of Natural Killer (NK) cell activity for immunotherapy using a novel flow cytometry-based killing assay
    Chan, R.
    Goetz, C.
    Peng, L.
    Faulkner, B.
    van Etten, J.
    Miller, A.
    Mishra, H.
    Hammerbeck, C.
    Herr, G.
    Perell, G.
    Johnson, C.
    Lomakin, J.
    Hermanson, D.
    Flynn, K.
    Bonnevier, J.
    HUMAN GENE THERAPY, 2021, 32 (19-20) : A35 - A36
  • [38] A novel flow cytometry-based cell capture platform for the detection, capture and molecular characterization of circulating tumor cells
    Koh, Yasuhiro
    Watanabe, Masaru
    Sawada, Takeshi
    Kenmotsu, Hirotsugu
    Serizawa, Masakuni
    Ishige, Masayuki
    Takeda, Kazuo
    Yamamoto, Nobuyuki
    Takahashi, Toshiaki
    Koizumi, Fumiaki
    CANCER RESEARCH, 2014, 74 (19)
  • [39] LEUKEMIC STEM CELL-RELATED MRNA EXPRESSION ANALYSIS USING A NOVEL FLOW CYTOMETRY-BASED ASSAY
    Depreter, B.
    Vandepoele, K.
    De Moerloose, B.
    Denys, B.
    Philippe, J.
    Lammens, T.
    HAEMATOLOGICA, 2017, 102 : 457 - 458
  • [40] Nuclear factor activation by FcγR in human peripheral blood neutrophils detected by a novel flow cytometry-based method
    Garcia-Garcia, Erick
    Rosales, Carlos
    JOURNAL OF IMMUNOLOGICAL METHODS, 2007, 320 (1-2) : 104 - 118