Modified Technique of Percutaneous Posterior Columnar Screw Insertion and Neutralization Plate for Complex Acetabular Fractures

被引:13
|
作者
Yu, Yi-Hsun
Tseng, I-Chuan
Su, Chun-Yi [1 ]
Huang, Jau-Wen
Wu, Chi-Chung
机构
[1] Chang Gung Mem Hosp, Dept Orthoped Surg, Div Traumatol, Tao Yuan, Taiwan
关键词
Acetabulum; Percutaneous; Kocher-Langenbeck approach; PELVIC RING DISRUPTIONS; OPERATIVE TREATMENT; RADIATION EXPOSURE; OPEN REDUCTION; FIXATION; ANTERIOR; CLASSIFICATION;
D O I
10.1097/TA.0b013e3181f2d50f
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: To overcome the complexity of acetabular fractures, several techniques, such as extensive surgical exposure, transtrochanteric osteotomy, and columnar screw fixation, were reported. However, all these techniques have their disadvantages and limitations. We report the surgical results of a modified technique with posterior columnar screw insertion and neutralization plate in a single Kocher-Langenbeck approach for complex acetabular fractures. Methods: We identified 30 patients with 30 acetabular fractures who had been treated by this technique between 1995 and 2004. Demographic data, perioperative results, and complications were all recorded. The detail of surgical procedure was described and illustrated. Results: There were 13 men and 17 women with mean age of 36.4 years (range, 19-66 years). Mean follow-up duration was 49.2 months (range, 24-112 months). All fractures achieved union, and there was no loss reduction and fixation during the follow-up period. There were five complications during hospital stay, including superficial and deep infection and transient sciatic nerve palsy. There was no loss of reduction during follow-up period. Five patients underwent total hip arthroplasty caused by posttraumatic osteoarthritis and preexisting osteoarthritis. The mean Harris Hip Score at 24-month follow-up was 79.7 (median, 92; range, 33-99). Conclusion: This study provided a modified surgical technique of percutaneous insertion of posterior columnar screw that appeared to be safe and reliably hold the column in place for healing.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [21] Percutaneous Iliosacral Screw Fixation for fractures and disruptions of the posterior pelvic ring - technique and perioperative complications
    Osterhoff, Georg
    Ossendorf, Christian
    Wanner, Guido A.
    Simmen, Hans-Peter
    Werner, Clement M.
    SWISS MEDICAL WEEKLY, 2010, 140 (23-24) : 6S - 6S
  • [22] The placement of percutaneous retrograde acetabular posterior column screw based on imaging anatomical study of acetabular posterior column corridor
    Yu, Kequan
    Zhou, Runtao
    Gao, Shichang
    Liang, Anlin
    Yang, Mingming
    Yang, Haitao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [23] Oblique-ilioischial plate technique: a novel method for acetabular fractures involving low posterior column
    Zhong Chen
    Zhao-xiang Wu
    Ge Chen
    Yi Ou
    Hong-jie Wen
    BMC Musculoskeletal Disorders, 23
  • [24] Anatomical Posterior Acetabular Plate Versus Conventional Reconstruction Plates for Acetabular Posterior Wall Fractures: A Comparative Study
    Chuang, Chang-Han
    Chuang, Hao-Chun
    Wang, Jou-Hua
    Yang, Jui-Ming
    Wu, Po-Ting
    Hu, Ming-Hsien
    Su, Hong-Lin
    Lee, Pei-Yuan
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (17)
  • [25] Oblique-ilioischial plate technique: a novel method for acetabular fractures involving low posterior column
    Chen, Zhong
    Wu, Zhao-Xiang
    Chen, Ge
    Ou, Yi
    Wen, Hong-Jie
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [26] A short buttress plate fixation of posterior column through single ilioinguinal approach for complex acetabular fractures
    Zhuang, Yan
    Zhang, Kun
    Wang, Hu
    Wei, Xing
    Liu, Ping
    Wang, Peng-fei
    Cong, Yu-xuan
    Lei, Jin-lai
    Kandemir, Utku
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (01) : 165 - 171
  • [27] A short buttress plate fixation of posterior column through single ilioinguinal approach for complex acetabular fractures
    Yan Zhuang
    Kun Zhang
    Hu Wang
    Xing Wei
    Ping Liu
    Peng-fei Wang
    Yu-xuan Cong
    Jin-lai Lei
    Utku Kandemir
    International Orthopaedics, 2017, 41 : 165 - 171
  • [28] A safe technique of anterior column lag screw fixation in acetabular fractures
    Sen, Ramesh Kumar
    Tripathy, Sujit Kumar
    Aggarwal, Sameer
    Goyal, Tarun
    Meena, Dharm S.
    Mahapatra, Santosh
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (11) : 2333 - 2340
  • [29] A safe technique of anterior column lag screw fixation in acetabular fractures
    Ramesh Kumar Sen
    Sujit Kumar Tripathy
    Sameer Aggarwal
    Tarun Goyal
    Dharm S. Meena
    Santosh Mahapatra
    International Orthopaedics, 2012, 36 : 2333 - 2340
  • [30] Posterior wall osteotomy to facilitate reduction of complex acetabular fractures
    Putnis, S. E.
    Data-ali, B. M.
    Bircher, M.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (10): : 1214 - 1217