Optimal PMU Placement for Complete Power System Observability using Binary Cat Swarm Optimization

被引:0
|
作者
Srivastava, Ankur [1 ]
Maheswarapu, Sydulu [1 ]
机构
[1] NIT Warangal, Dept Elect Engn, Warangal, Andhra Pradesh, India
关键词
Cat Swarm Optimization; Swarm Intelligence; Phasor Measurement Unit; Observability;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a meta-heuristic algorithm using Binary Cat Swarm Optimization (BCSO). BCSO is binary version of Cat Swarm Optimization (CSO) based on the observation of the behavior of cats. BCSO has two modes of operation: seeking mode and tracing mode. This proposed methodology is used for the optimal placement of phasor measurement units (PMUs) for complete observability of a power system. The objective of this optimization problem is the minimization of the total number of PMUs required by keeping the observability of the system intact. The proposed algorithm was examined with IEEE 14-bus and IEEE 30-bus test system and their results are presented in the paper. These results were also verified with different existing conventional and meta-heuristic algorithms such as binary particle swarm optimization, generalized integer linear programming and effective data structure based algorithm. It is first time that the proposed binary cat swarm optimization has been contemplated for the problem of optimal placement of PMUs.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Observability enhancement by optimal PMU placement considering random power system outages
    Aminifar F.
    Fotuhi-Firuzabad M.
    Shahidehpour M.
    Khodaei A.
    Energy Systems, 2011, 2 (01) : 45 - 65
  • [22] Differential Evolution Based Optimal PMU Placement for Fault Observability of Power System
    Rajasekhar, Batchu
    Chandel, Ashwani Kumar
    Vedik, Basetti
    2013 STUDENTS CONFERENCE ON ENGINEERING AND SYSTEMS (SCES): INSPIRING ENGINEERING AND SYSTEMS FOR SUSTAINABLE DEVELOPMENT, 2013,
  • [23] Power System State Estimation Accuracy and Observability Evaluation with Optimal PMU Placement
    Almehizia, Abdullah. A.
    Alismail, Fahad. S.
    2017 IEEE TEXAS POWER AND ENERGY CONFERENCE (TPEC), 2017,
  • [24] An optimal PMU placement method for power system observability under various contingencies
    Abiri, Ebrahim
    Rashidi, Farzan
    Niknam, Taher
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (04): : 589 - 606
  • [25] System Observability Indices for Optimal Placement of PMU Measurements
    Powalko, M.
    Orths, A. G.
    Abildgaard, H.
    Eriksen, P. B.
    Rudion, K.
    Golub, I. I.
    Voropai, N. I.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [26] Optimal PMU placement for power system observability considering secondary voltage control
    Mohammadi-Ivatloo, B.
    Hosseini, S. H.
    2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, : 352 - +
  • [27] Hierarchical Clustering based optimal PMU placement for power system fault observability
    Eissa, Moustafa
    Kassem, Amr
    HELIYON, 2018, 4 (08):
  • [28] OPTIMAL PLACEMENT OF PMU WITH OPTIMAL BRANCH CURRENT PHASORS FOR COMPLETE AND INCOMPLETE OBSERVABILITY
    Sajan, K. S.
    Tyagi, Barjeev
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [29] PMU Placement for Maximal Power System Observability Using Topology Transformation
    Bawayan, Haneen
    Younis, Mohamed
    2019 IEEE SUSTAINABILITY THROUGH ICT SUMMIT (STICT), 2019, : 1 - 7
  • [30] Complete and Incomplete Observability Analysis by Optimal PMU Placement Techniques of a Network
    Krishna, K. Bala
    Rosalina, K. Mercy
    Ramaraj, N.
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2018, 13 (05) : 1814 - 1820