Evaluation of image quality of pituitary dynamic contrast-enhanced MRI using time-resolved angiography with interleaved stochastic trajectories (TWIST) and iterative reconstruction TWIST (IT-TWIST)

被引:10
|
作者
Yokota, Yusuke [1 ]
Fushimi, Yasutaka [1 ]
Okada, Tomohisa [2 ]
Fujimoto, Koji [2 ]
Oshima, Sonoko [1 ]
Nakajima, Satoshi [1 ]
Fujii, Toshihito [3 ]
Tanji, Masahiro [4 ]
Inagaki, Nobuya [3 ]
Miyamoto, Susumu [4 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Diagnost Imaging & Nucl Med, Kyoto, Japan
[2] Kyoto Univ, Human Brain Res Ctr, Grad Sch Med, Kyoto, Japan
[3] Kyoto Univ, Grad Sch Med, Dept Diabet Endocrinol & Nutr, Kyoto, Japan
[4] Kyoto Univ, Grad Sch Med, Dept Neurosurg, Kyoto, Japan
基金
日本学术振兴会;
关键词
magnetic resonance imaging; pituitary gland; central nervous system; CAVERNOUS SINUS; DCE-MRI; GLAND; GADOLINIUM; PATTERNS; PROTOCOL;
D O I
10.1002/jmri.26962
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Time-resolved angiography with interleaved stochastic trajectories (TWIST) is a keyhole imaging with frequent sampling of central k-space data and view-sharing for the peripheral k-space of dynamic phases. IT-TWIST is a technique to reconstruct images with a smaller temporal footprint using the same raw data obtained with TWIST by iterative reconstruction. Purpose To compare image quality between TWIST and IT-TWIST in 3D pituitary DCE-MRI. Study Type Retrospective observation study. Population Fifty-one patients (23 men, 28 women) who underwent 3D pituitary DCE-MRI using TWIST between July 2016 and April 2017. Field Strength/Sequence 3T/TWIST and IT-TWIST. Assessment Visual evaluation was conducted for image quality of delineation of the pituitary stalk and posterior lobe during the early arterial phase, cerebral white matter near the sella turcica, and the mass lesion. Bolus sharpness of the pituitary stalk, posterior lobe, and bilateral cavernous sinus was evaluated on the enhancement slope map calculated from TWIST and IT-TWIST. Temporal stability of intensity of the nonenhanced area was evaluated on temporal standard deviation (SD) maps calculated from TWIST and IT-TWIST. Statistical Tests Paired t-test or Wilcoxon rank-sum test was used to test the differences between TWIST and IT-TWIST in both visual evaluation and region of interest evaluation. Results Scores of visual evaluations for IT-TWIST were significantly better than those for TWIST (P < 0.001) in all items. Enhancement slope for IT-TWIST was significantly higher than that for TWIST in posterior lobe, and right and left cavernous sinus (P < 0.001). Temporal SD for IT-TWIST was significantly lower than that for TWIST in all items, with statistical significance (P < 0.001). Data Conclusion IT-TWIST yielded better visualization, and better enhancement slope, and less temporal SD compared with TWIST in 3D pituitary DCE-MRI. Evidence Level: 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:1497-1506.
引用
收藏
页码:1497 / 1506
页数:10
相关论文
共 28 条
  • [21] 3D Time-Resolved MR Angiography (MRA) of the Carotid Arteries with Time-Resolved Imaging with Stochastic Trajectories: Comparison with 3D Contrast-Enhanced Bolus-Chase MRA and 3D Time-Of-Flight MRA
    Lim, R. P.
    Shapiro, M.
    Wang, E. Y.
    Law, M.
    Babb, J. S.
    Rueff, L. E.
    Jacob, J. S.
    Kim, S.
    Carson, R. H.
    Mulholland, T. P.
    Laub, G.
    Hecht, E. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (10) : 1847 - 1854
  • [22] Detection of early venous filling in gliomas on MRI: Preliminary Study by 2D time-resolved dynamic contrast-enhanced MR angiography with echo-sharing technique
    Sakamoto, M
    Taoka, T
    Iwasaki, S
    Fukusumi, A
    Nakagawa, H
    Hirohashi, S
    Takayama, K
    Wada, T
    Kichikawa, K
    Uchida, H
    Ohishi, H
    Murata, K
    MAGNETIC RESONANCE IMAGING, 2001, 19 (09) : 1193 - 1201
  • [23] Feasibility of Noninvasive Diagnosis and Treatment Planning in a Case Series with Carotid-Cavernous Fistula using High-Resolution Time-Resolved MR-Angiography with Stochastic Trajectories (TWIST) and Extended Parallel Acquisition Technique (ePAT 6) at 3 T
    A. Seeger
    U. Kramer
    F. Bischof
    F. Schuettauf
    F. Ebner
    S. Danz
    U. Ernemann
    T.-K. Hauser
    Clinical Neuroradiology, 2015, 25 : 241 - 247
  • [24] Feasibility of Noninvasive Diagnosis and Treatment Planning in a Case Series with Carotid-Cavernous Fistula using High-Resolution Time-Resolved MR-Angiography with Stochastic Trajectories (TWIST) and Extended Parallel Acquisition Technique (ePAT 6) at 3 T
    Seeger, A.
    Kramer, U.
    Bischof, F.
    Schuettauf, F.
    Ebner, F.
    Danz, S.
    Ernemann, U.
    Hauser, T. -K.
    CLINICAL NEURORADIOLOGY, 2015, 25 (03) : 241 - 247
  • [25] Time-resolved visualization of the coronary arteries with contrast-enhanced, 3D undersampled projection reconstruction (PR) MR angiography in a single breath-hold using an intravascular contrast agent
    Barger, AV
    Hany, TF
    Block, WF
    Mistretta, CA
    Grist, TM
    RADIOLOGY, 2000, 217 : 285 - 285
  • [26] Time-resolved visualization of the coronary arteries with contrast-enhanced, 3D undersampled projection reconstruction (PR) MR angiography in a single breath-hold using an intravascular contrast agent
    Hany, TF
    Barger, AV
    Mistretta, CA
    Grist, TM
    CIRCULATION, 2000, 102 (18) : 399 - 399
  • [27] Pretreatment Evaluation of Peripheral Vascular Malformations Using Low-Dose Contrast-Enhanced Time-Resolved 3D MR Angiography: Initial Results in 22 Patients
    Kramer, Ulrich
    Ernemann, Ulrike
    Fenchel, Michael
    Seeger, Achim
    Laub, Gerhard
    Claussen, Claus D.
    Miller, Stephan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (03) : 702 - 711
  • [28] Diagnostic Performance of a Lower-dose Contrast-Enhanced 4D Dynamic MR Angiography of the Lower Extremities at 3 T Using Multisegmental Time-Resolved Maximum Intensity Projections
    Raczeck, Paul
    Fries, Peter
    Massmann, Alexander
    Minko, Peter
    Frenzel, Felix
    Woerner, Tobias
    Buecker, Arno
    Schneider, Guenther K.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (03) : 763 - 774