A review of setup error in supine breast radiotherapy using cone -beam computed tomography

被引:35
|
作者
Batumalai, Vikneswary [1 ,2 ,3 ]
Holloway, Lois [1 ,2 ,3 ,4 ,5 ]
Delaney, Geoff P. [1 ,2 ,3 ]
机构
[1] Univ New South Wales, South Western Clin Sch, Sydney, NSW, Australia
[2] Liverpool & Macarthur Canc Therapy Ctr, Campbelltown, NSW, Australia
[3] Ingham Inst Appl Med Res, Sydney, NSW, Australia
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[5] Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW, Australia
关键词
Breast cancer; Cone-beam computed tomography (CBCT); Radiotherapy; Review; Setup errors; IMAGE-GUIDED RADIOTHERAPY; INTER-FRACTION MOTION; SURGICAL CLIPS; DOSIMETRIC CONSEQUENCES; LUMPECTOMY CAVITY; RADIATION-THERAPY; CLINICAL-PRACTICE; INTRA-FRACTION; WHOLE-BREAST; IRRADIATION;
D O I
10.1016/j.meddos.2016.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Setup error in breast radiotherapy (RT) measured with 3-dimensional cone-beam computed tomography (CBCT) is becoming more common. The purpose of this study is to review the literature relating to the magnitude of setup error in breast RT measured with CBCT. The different methods of image registration between CBCT and planning computed tomography (CT) scan were also explored. A literature search, not limited by date, was conducted using Medline and Google Scholar with the following key words: breast cancer, RT, setup error, and CBCT. This review includes studies that reported on systematic and random errors, and the methods used when registering CBCT scans with planning CT scan. A total of 11 relevant studies were identified for inclusion in this review. The average magnitude of error is generally less than 5 mm across a number of studies reviewed. The common registration methods used when registering CBCT scans with planning CT scan are based on bony anatomy, soft tissue, and surgical clips. No clear relationships between the setup errors detected and methods of registration were observed from this review. Further studies are needed to assess the benefit of CBCT over electronic portal image, as CBCT remains unproven to be of wide benefit in breast RT. (C) 2016 American Association of Medical Dosimetrists.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 50 条
  • [21] Cone Beam Computed Tomography for Adaptive Radiotherapy Treatment Planning
    Srinivasan, Kavitha
    Mohammadi, Mohammad
    Shepherd, Justin
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2014, 34 (04) : 377 - 385
  • [22] A Study on Image Guided Radiotherapy Using Cone-Beam Computed Tomography (CBCT) for Head and Neck Cancer IMRT Patient Setup
    Tang, X.
    Chera, B.
    Lian, J.
    Deschesne, K.
    Chang, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [23] A preliminary study for a cone-beam computed, tomography (CBCT) setup using a newly developed image-guided radiotherapy system
    Takayama, K.
    Kawada, N.
    Nagano, K.
    Sato, Y.
    Matsuo, Y.
    Mizowaki, T.
    Kokubo, M.
    Nakayama, H.
    Narital, Y.
    Hiraoka, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S631 - S631
  • [24] Image-guided radiotherapy for liver cancer using respiratorycorrelated computed tomography and cone-beam computed tomography
    Guckenberger, Matthias
    Sweeney, Reinhart A.
    Wilbert, Juergen
    Krieger, Thomas
    Richter, Anne
    Baier, Kurt
    Mueller, Gerd
    Sauer, Otto
    Flentje, Michael
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : 297 - 304
  • [25] Fractionated changes in prostate cancer radiotherapy using cone-beam computed tomography
    Huang, Tzung-Chi
    Chou, Kuei-Ting
    Yang, Shih-Neng
    Chang, Chih-Kai
    Liang, Ji-An
    Zhang, Geoffrey
    MEDICAL DOSIMETRY, 2015, 40 (03) : 222 - 225
  • [26] Retroperitoneal tumour radiotherapy: clinical improvements using kilovoltage cone beam computed tomography
    Juan-Senabre, Xavier J.
    Ferrer-Albiach, Carlos
    Rodriguez-Cordon, Marta
    Santos-Serra, Agustin
    Lopez-Tarjuelo, Juan
    Calzada-Feliu, Salvador
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2009, 11 (04): : 253 - 256
  • [27] QUALITY ASSESSMENT OF FRAMELESS FRACTIONATED STEREOTACTIC RADIOTHERAPY USING CONE BEAM COMPUTED TOMOGRAPHY
    Peng, Lee-Cheng
    Kahler, Darren
    Samant, Sanjiv
    Li, Jonathan
    Amdur, Robert
    Palta, Jatinder R.
    Liu, Chihray
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05): : 1586 - 1593
  • [28] Retroperitoneal tumour radiotherapy: clinical improvements using kilovoltage cone beam computed tomography
    Xavier J. Juan-Senabre
    Carlos Ferrer-Albiach
    Marta Rodríguez-Cordón
    Agustín Santos-Serra
    Juan López-Tarjuelo
    Salvador Calzada-Feliu
    Clinical and Translational Oncology, 2009, 11 : 253 - 256
  • [29] Patient setup error and day-to-day esophageal motion error analyzed by cone-beam computed tomography in radiation therapy
    Yamashita, Hideomi
    Haga, Akihiro
    Hayakawa, Yayoi
    Okuma, Kae
    Yoda, Kiyoshi
    Okano, Yukari
    Tanaka, Ken-ichiro
    Imae, Toshikazu
    Ohtomo, Kuni
    Nakagawa, Keiichi
    ACTA ONCOLOGICA, 2010, 49 (04) : 485 - 490
  • [30] ACCURACY AND DOSE OF A CONE-BEAM COMPUTED TOMOGRAPHY FOR STEREOTACTIC RADIOSURGERY SETUP
    Sancho, I.
    Modolell, I.
    Ferrer, F.
    Lizuain, M. C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S422 - S422