Study of the relative dose-response of BANG-3® polymer gel dosimeters in epithermal neutron irradiation

被引:26
|
作者
Uusi-Simola, J [1 ]
Savolainen, S
Kangasmäki, A
Heikkinen, S
Perkiö, J
Ramadan, UA
Seppälä, T
Karila, J
Serén, T
Kotiluoto, P
Sorvari, P
Auterinen, I
机构
[1] Univ Helsinki, Cent Hosp, Dept Radiol, FIN-00029 Helsinki, Finland
[2] Univ Helsinki, Cent Hosp, Dept Lab Diagnost, FIN-00029 Helsinki, Finland
[3] Univ Helsinki, Cent Hosp, Dept Oncol, FIN-00029 Helsinki, Finland
[4] Univ Helsinki, Dept Phys Sci, FIN-00014 Helsinki, Finland
[5] Varian Med Syst Finland, FIN-00270 Helsinki, Finland
[6] Tech Res Ctr Finland, VTT Proc, FIN-02044 Espoo, Finland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 17期
关键词
D O I
10.1088/0031-9155/48/17/310
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polymer gels have been reported as a new, potential tool for dosimetry in mixed neutron-gamma radiation fields. In this work, BANG-3 (MGS Research Inc.) gel vials from three production batches were irradiated with 6 MV photons of a Varian Clinac 2100 C linear accelerator and with the epithermal neutron beam of the Finnish boron neutron capture therapy (BNCT) facility at the FiR I nuclear reactor. The gel is tissue equivalent in main elemental composition and density and its T2 relaxation time is dependent on the absorbed dose. The T2 relaxation time map of the irradiated gel vials was measured with a 1.5 T magnetic resonance (MR) scanner using spin echo sequence. The absorbed doses of neutron irradiation were calculated using DORT computer code, and the accuracy of the calculational model was verified by measuring gamma ray dose rate with thermoluminescent dosimeters and Mn-55(n,gamma) activation reaction rate with activation detectors. The response of the BANG-3 gel dosimeter for total absorbed dose in the neutron irradiation was linear, and the magnitude of the response relative to the response in the photon irradiation was observed to vary between different gel batches. The results support the potential of polymer gels in BNCT dosimetry, especially for the verification of two- or three-dimensional dose distributions.
引用
收藏
页码:2895 / 2906
页数:12
相关论文
共 50 条
  • [1] Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters
    De Deene, Y
    Venning, A
    Hurley, C
    Healy, BJ
    Baldock, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (14): : 2459 - 2470
  • [2] Development of BANG-3® Polymer Gel Dosimetry System in Small Radiosurgical Fields
    Kang, Young-Nam
    Choi, Byung Ock
    Jang, Hong-Seok
    Kay, Chul Seung
    Son, Seok Hyun
    Shin, Hun-Joo
    Jung, Ji-Young
    Choi, Ihl-Bohng
    Lee, Gi Woong
    Park, Hyong Wook
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (06) : 3422 - 3427
  • [3] Preparation of polymer gel dosimeters for low gamma irradiation dose
    El-Kelany, Moushera A.
    Khozemy, Ehab E.
    Goda, Heba
    Awad, Boshra
    RADIOCHIMICA ACTA, 2023, 111 (03) : 195 - 202
  • [4] DYNAMIC MODELLING OF THE DOSE RESPONSE OF POLYMER GEL DOSIMETERS
    Ceberg, S.
    Lepage, M.
    Back, S.
    Gustafsson, H.
    Ceberg, C.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S408 - S409
  • [5] A comparison of the dose-response behavior of AQUAJOINT®-based polymer gel and PAGAT gel dosimeters measured using Optical CT and MRI
    Takanashi, Takaoki
    Kawamura, Hiraku
    Fukasaku, Kazuaki
    Sahade, Daniel Antonio
    Hamada, Toshimasa
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [6] Polymer gel dosimeters with reduced toxicity: a preliminary investigation of the NMR and optical dose-response using different monomers
    Senden, R. J.
    De Jean, P.
    McAuley, K. B.
    Schreiner, L. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14): : 3301 - 3314
  • [7] Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter
    Maryanski, MJ
    Audet, C
    Gore, JC
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (02): : 303 - 311
  • [8] Sensitivity calibration procedures in optical-CT scanning of BANG®3 polymer gel dosimeters
    Xu, Y.
    Wuu, Cheng-Shie
    Maryanski, Marek J.
    MEDICAL PHYSICS, 2010, 37 (02) : 861 - 868
  • [9] Preliminary investigation of the NMR, optical and x-ray CT dose-response of polymer gel dosimeters incorporating cosolvents to improve dose sensitivity
    Koeva, V. I.
    Olding, T.
    Jirasek, A.
    Schreiner, L. J.
    McAuley, K. B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09): : 2779 - 2790
  • [10] Mathematical Modeling of Depth-Dose Response of Polymer-Gel Dosimeters
    Chain, Jonathan N. M.
    Nasr, Abdullah T.
    Schreiner, L. John
    McAuley, Kim B.
    MACROMOLECULAR THEORY AND SIMULATIONS, 2011, 20 (08) : 735 - 751