A novel refrigerant-direct radiant cooling system: Numerical simulation-based evaluation

被引:10
|
作者
Jiang, Tingting [1 ]
You, Shijun [1 ,2 ]
Wu, Zhangxiang [1 ]
Zhang, Huan [1 ,2 ]
Wang, Yaran [1 ,2 ]
Wei, Shen [3 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Haihe Educ Area, Tianjin 300350, Peoples R China
[2] Tianjin Univ, Key Lab Efficient Utilizat Low & Medium Grade Ene, Minist Educ China, Tianjin 300350, Peoples R China
[3] Univ Coll London UCL, Bartlett Sch Construct & Project Management, 1-19 Torrington Pl, London WC1E 7HB, England
基金
中国国家自然科学基金;
关键词
Refrigerant-direct radiant cooling system; Mathematical and economic models; Thermal and economic performances; Optimal structure; HEAT-TRANSFER; THERMAL COMFORT; CEILING PANEL; FLOOR; DESIGN; HOT; PERFORMANCE; HUMIDITY; CAPACITY;
D O I
10.1016/j.applthermaleng.2021.117442
中图分类号
O414.1 [热力学];
学科分类号
摘要
Split air-conditioners have deficiency in thermal comfort due to draught sensation and fan noise. The existing radiant cooling systems adopt chilled water as circulating medium, resulting in low energy efficiency because of the requirement of secondary heat exchange. To address these problems, a novel refrigerant-direct radiant cooling (RDRC) system is proposed. Experiments are conducted in a climate chamber to evaluate the thermal performance of this system. Results show that the RDRC terminal surface temperature is distributed homogenously and this system has excellent stability. The mathematical and economic models of this terminal are established and the mathematical model is validated with experimental data. The effects of different structural parameters on thermal and economic performances of the RDRC system are investigated, and then this terminal is optimized by orthogonal design method. The cooling capacity for per exterior area is considered as objective function and the initial cost less than 121.1 $ is taken as constraint condition. Results indicate that the fin height of 40.0 mm, the copper pipe diameter of 6.0 mm, the copper pipe spacing of 40.0 mm and the aspect ratio of 0.88 are recommended.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Evaporation temperature prediction of the refrigerant-direct convective-radiant cooling system based on LSTM neural network
    Jiang, Tingting
    Zheng, Chenxiao
    Wang, Hanqing
    You, Shijun
    Zhang, Huan
    Wang, Yaran
    Sun, Jing
    Wu, Zhenjing
    Zhao, Wenyuan
    Zheng, Jia
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [2] Multi-objective optimization of the refrigerant-direct convective-radiant cooling system considering the thermal and economic performances
    Jiang, Tingting
    You, Shijun
    Wu, Zhangxiang
    Zhang, Huan
    Wang, Yaran
    Wei, Shen
    ENERGY AND BUILDINGS, 2022, 254
  • [3] Design and analysis of electric vehicle thermal management system based on refrigerant-direct cooling and heating batteries
    Wang, Z. R.
    Huang, L. P.
    He, F.
    JOURNAL OF ENERGY STORAGE, 2022, 51
  • [4] Performance analysis of the refrigerant-cooling radiant terminal: A numerical simulation
    Jiang, Tingting
    You, Shijun
    Wu, Zhangxiang
    Zhang, Huan
    Wang, Yaran
    Wei, Shen
    APPLIED THERMAL ENGINEERING, 2021, 197
  • [5] Numerical simulation of radiant floor cooling system
    Jin, Xing
    Zhang, Xiaosong
    Cao, Rongquan
    Cao, Yiran
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2010, 31 (06): : 732 - 737
  • [6] All-air system and radiant floor for heating and cooling in residential buildings: A simulation-based analysis
    Alessio, Giulia
    Emmi, Giuseppe
    De Carli, Michele
    Zarrella, Angelo
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 26 (10) : 1397 - 1411
  • [7] Radiant floor cooling coupled with dehumidification systems in residential buildings: A simulation-based analysis
    Zarrella, Angelo
    De Carli, Michele
    Peretti, Clara
    ENERGY CONVERSION AND MANAGEMENT, 2014, 85 : 254 - 263
  • [8] Numerical simulation of cooling performance of radiant ceiling system interacting with a ceiling fan
    Guo, Xingguo
    Wan, Shuangshuang
    Chen, Wenhua
    Zhang, Hui
    Arens, Edward
    Cheng, Yuanda
    Pasut, Wilmer
    ENERGY AND BUILDINGS, 2023, 297
  • [9] Numerical simulation of radiant ceiling panels for indoor cooling
    Cammarata, Giuliano
    Petrone, Giuseppe
    Masi, Filippo
    33RD UIT (ITALIAN UNION OF THERMO-FLUID DYNAMICS) HEAT TRANSFER CONFERENCE, 2015, 655
  • [10] Numerical Simulation on Indoor Thermal Environment of Radiant Flooring Cooling System with Displacement Ventilation
    Cai, Wei
    Lv, Wen
    Zhu, Lexian
    Yang, Pengfeng
    BUILDING MATERIALS AND STRUCTURAL ENGINEERING II, 2013, 743 : 90 - +