Analysis of electromagnetic interference on DC line from parallel AC line in close proximity

被引:30
|
作者
Tang, Han [1 ]
Zeng, Rong
Ma, Hongbin
He, Jinhang
Zhao, He
Li, Xiaolin
Wang, Qi
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
[2] Technol Res Ctr, China So Power Grid, Guangzhou 510620, Peoples R China
基金
中国国家自然科学基金;
关键词
capacitive coupling; electromagnetic interference; HVDC transmission line; inductive coupling; parallel ac/dc transmission lines;
D O I
10.1109/TPWRD.2007.905334
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the need for electric power grows continuously, transmission systems with more delivery capability, such as HVDC lines, are also needed. However, one of the biggest obstacles to construct a new transmission system is the obtaining of sufficient right-of-way, due mainly to the economical and ecological reasons. As a consequence, ac and dc transmission lines are to be built in parallel sharing the same right-of-way. In this paper, the electromagnetic interference in a dc line, due to the capacitive and inductive coupling from a parallel ac line in close proximity, is studied in detail. A multiconductor transmission line model is elaborated in the electromagnetic transient program to calculate the induced voltage from an ac line upon a dc line. A method based on Fourier series theory, to obtain the direct current flowing into the converting transformer, is presented. The generated interferences upon the dc line are calculated and analyzed through an example regarding steady state and fault conditions. Finally, the influence of various parameters upon such interferences is discussed. The paper provides an insight on how to control the generated electromagnetic interference in the dc line on account of the induced voltage from the neighboring ac line.
引用
收藏
页码:2401 / 2408
页数:8
相关论文
共 50 条
  • [21] STUDY OF FAST SYNCHRONOUS-RECLOSING METHOD FOR PARALLEL AC LINE FAULT IN AC/DC POWER TRANSMISSION-SYSTEM
    MIZUKAMI, Y
    DOI, H
    KATSUKI, K
    SHIMOMURA, T
    IYODA, I
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (06): : 1135 - 1141
  • [22] The Measurement and Analysis of Electromagnetic Environment of DC Transmission Line in High Altitude Areas
    Tashi, Quda
    Yue, Song
    Duo, Bujie
    Gao, Lei
    Tenzin, Deji
    Li, Liugang
    Yang, Fan
    2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 147 - 150
  • [23] Design of Transmission Line and Electromagnetic Field Sensors for DC Partial Discharge Analysis
    Rostaghi-Chalaki, Mojtaba
    Yousefpour, Kamran
    Donohoe, J. Patrick
    Kurum, Mehmet
    Park, Chanyeop
    Kluss, Joni
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (06) : 2138 - 2146
  • [24] ELECTROMAGNETIC INTERFERENCE DUE TO HVDC TRANSMISSION LINE FAULTS
    Yang, Yixin
    Ma, Jinxi
    Fortin, Simon
    Dawalibi, Farid
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [25] Investigation of electromagnetic interference due to high voltage line
    Swaminathan Suvikar Samraj, J.
    Sivadasan, J.
    Proceedings of IEEE International Conference on Circuit, Power and Computing Technologies, ICCPCT 2013, 2013, : 310 - 314
  • [26] Investigation of Electromagnetic Interference due to High Voltage Line
    Samraj, J. Swaminathan Suvikar
    Sivadasan, J.
    PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT 2013), 2013, : 310 - 314
  • [27] FORMULAS FOR PREDICTING AUDIBLE NOISE FROM OVERHEAD HIGH-VOLTAGE AC-LINE AND DC-LINE
    CHARTIER, VL
    STEARNS, RD
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (01): : 121 - 130
  • [28] Loadability Improvement of an Existing AC Line by Transmitting Simultaneous AC and DC Power
    Alam, Mohammad Tawhidul
    Sadnan, R.
    Haque, Irtiza
    Rahman, Mushfequr
    Ahsan, Q.
    2016 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2016, : 479 - 482
  • [29] Voltage stability of AC-DC interconnections as affected by AC line length
    Folly, K. A.
    Mukusuka, J. K.
    2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 178 - 183
  • [30] Corona loss analysis of high voltage DC transmission lines in close proximity of high voltage AC transmission lines
    Beijing Key Laboratory on High Voltage and EMC , Changping District, Beijing 102206, China
    Zhongguo Dianji Gongcheng Xuebao, 31 (211-218):