Preliminary Figures of Merit for Isotope Ratio Measurements: The Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Ionization Source Coupled to an Orbitrap Mass Analyzer

被引:35
|
作者
Hoegg, Edward D. [1 ,2 ]
Barinaga, Charles J. [2 ]
Hager, George J. [2 ]
Hart, Garret L. [2 ]
Koppenaal, David W. [2 ]
Marcus, R. Kenneth [1 ]
机构
[1] Clemson Univ, Dept Chem, Clemson, SC 29634 USA
[2] Pacific Northwest Natl Lab, Richland, WA 99354 USA
关键词
Liquid sampling-atmospheric pressure glow discharge; Orbitrap mass analyzer; Isotope ratio analysis; Uranium; SPACE-CHARGE; ION-TRAP; EMISSION-SPECTROMETRY; PLASMA SOURCE; INSTRUMENTATION; ELECTROLYTE; PERFORMANCE;
D O I
10.1007/s13361-016-1402-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In order to meet a growing need for fieldable mass spectrometer systems for precise elemental and isotopic analyses, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) has a number of very promising characteristics. One key set of attributes that await validation deals with the performance characteristics relative to isotope ratio precision and accuracy. Owing to its availability and prior experience with this research team, the initial evaluation of isotope ratio (IR) performance was performed on a Thermo Scientific Exactive Orbitrap instrument. While the mass accuracy and resolution performance for Orbitrap analyzers are well-documented, no detailed evaluations of the IR performance have been published. Efforts described here involve two variables: the inherent IR precision and accuracy delivered by the LS-APGD microplasma and the inherent IR measurement qualities of Orbitrap analyzers. Important to the IR performance, the various operating parameters of the Orbitrap sampling interface, high-energy collisional dissociation (HCD) stage, and ion injection/data acquisition have been evaluated. The IR performance for a range of other elements, including natural, depleted, and enriched uranium isotopes was determined. In all cases, the precision and accuracy are degraded when measuring low abundance (< 0.1% isotope fractions). In the best case, IR precision on the order of 0.1% RSD can be achieved, with values of 1%-3% RSD observed for low-abundance species. The results suggest that the LS-APGD is a promising candidate for field deployable MS analysis and that the high resolving powers of the Orbitrap may be complemented with a here-to-fore unknown capacity to deliver high-precision IRs.
引用
收藏
页码:1393 / 1403
页数:11
相关论文
共 49 条
  • [1] Isotope ratio characteristics and sensitivity for uranium determinations using a liquid sampling-atmospheric pressure glow discharge ion source coupled to an Orbitrap mass analyzer
    Hoegg, Edward D.
    Barinaga, Charles J.
    Hager, George J.
    Hart, Garret L.
    Koppenaal, David W.
    Marcus, R. Kenneth
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (12) : 2355 - 2362
  • [2] Mass spectrometric characteristics and preliminary figures of merit for polyaromatic hydrocarbons via the liquid sampling-atmospheric pressure glow discharge microplasma
    Williams, Tyler J.
    Bills, Jacob R.
    Marcus, R. Kenneth
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (11) : 2475 - 2478
  • [3] Liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry: preliminary parametric evaluation and figures of merit
    Quarles, C. Derrick, Jr.
    Carado, Anthony J.
    Barinaga, Charles J.
    Koppenaal, David W.
    Marcus, R. Kenneth
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (01) : 261 - 268
  • [4] Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium
    Goodwin, Joseph V.
    Manard, Benjamin T.
    Ticknor, Brian W.
    Cable-Dunlap, Paula
    Marcus, R. Kenneth
    ANALYTICAL CHEMISTRY, 2023, 95 (32) : 12131 - 12138
  • [5] Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source for Elemental Mass Spectrometry
    Marcus, R. Kenneth
    Quarles, C. Derrick, Jr.
    Barinaga, Charles J.
    Carado, Anthony J.
    Koppenaal, David W.
    ANALYTICAL CHEMISTRY, 2011, 83 (07) : 2425 - 2429
  • [6] Combined atomic and molecular (CAM) ionization with the liquid sampling-atmospheric pressure glow discharge microplasma
    Kenneth Marcus, R.
    Hoegg, Edward D.
    Hall, Katja A.
    Williams, Tyler J.
    Koppenaal, David W.
    MASS SPECTROMETRY REVIEWS, 2023, 42 (02) : 652 - 673
  • [7] Concomitant ion effects on isotope ratio measurements with liquid sampling - atmospheric pressure glow discharge ion source Orbitrap mass spectrometry
    Hoegg, Edward D.
    Marcus, R. Kenneth
    Hager, George J.
    Hart, Garret L.
    Koppenaal, David W.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (02) : 251 - 259
  • [8] Preliminary investigation of an uncertainty budget for uranium isotope ratio analysis using a liquid sampling-atmospheric pressure glow discharge-orbitrap mass spectrometer system
    Goodwin, Joseph V.
    Manard, Benjamin T.
    Ticknor, Brian W.
    Rogers, Kayron T.
    Hexel, Cole R.
    Cable-Dunlap, Paula
    Marcus, R. Kenneth
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2023, 332 (7) : 2875 - 2886
  • [9] Mass spectra of diverse organic species utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source
    Zhang, Lynn X.
    Marcus, R. Kenneth
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (01) : 145 - 151
  • [10] Coupling of the Liquid Sampling-Atmospheric Pressure Glow Discharge to Orbitrap Mass Analyzers for Uranium Isotope Ratio Analysis: Evolution of the Methodology and Implications to the Field
    Koppenaal, David W.
    Marcus, R. Kenneth
    APPLIED SPECTROSCOPY, 2023, 77 (08) : 885 - 906