Direct Comparison of DC Josephson Voltage Standard and Programmable Josephson Voltage Standard of TUBITAK UME

被引:0
|
作者
Turhan, Saliha [1 ]
Kanatoglu, Naylan [1 ]
Orhan, Recep [1 ]
机构
[1] TUBITAK Ulusal Metol Estitusu UME, P Box 54, TR-41470 Gebze, Turkey
关键词
DC voltage; Josephson voltage standard; Programmable Josephson voltage standard; comparison of measurement standards; uncertainty;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
10 V programmable Josephson voltage standard (PJVS) has been setup at TUBITAK Ulusal Metroloji Enstitusu (UME), national metrology institute of Turkey. The PJVS has compared to 10 V DC Josephson Array Voltage Standard (JVS) of TUBITAK UME which is regularly used for the calibration of DC Voltage Standards and DC voltage meters since 1997. A direct comparison between two Josephson voltage standards was carried out at the level of 10 V in order to verify the accuracy of the PJVS. The difference between the two systems (JVS - PJVS) was +0.96 nV with an uncertainty of 2.4 parts in 10(-10) (k = 1).
引用
收藏
页数:2
相关论文
共 50 条
  • [1] 10 V Programmable Josephson Voltage Standard Established in TUBITAK UME
    Arifovic, Mehedin
    Orhan, Recep
    Kanatoglu, Naylan
    [J]. 2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [2] DC Comparison of a Programmable Josephson Voltage Standard and a Josephson Arbitrary Waveform Synthesizer
    Rufenacht, Alain
    Flowers-Jacobs, Nathan E.
    Fox, Anna E.
    Waltman, Steven B.
    Schwall, Robert E.
    Burroughs, Charles J.
    Dresselhaus, Paul D.
    Benz, Samuel P.
    [J]. 2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [3] Application of a 10 V Programmable Josephson Voltage Standard in Direct Comparison With Conventional Josephson Voltage Standards
    Tang, Yi-Hua
    Wachter, James
    Ruefenacht, Alain
    FitzPatrick, Gerald J.
    Benz, Samuel P.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (12) : 3458 - 3466
  • [4] Direct Comparison between the NIST 10 V Conventional Josephson Voltage Standard and 2.5 V Programmable Josephson Voltage Standard
    Jaiswal, Shiv Kumar
    [J]. MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2011, 26 (04): : 339 - 348
  • [5] Direct comparison between the NIST 10 V Compact Josephson Voltage Standard and the 2.5 V Programmable Josephson Voltage Standard
    Jaiswal, Shiv Kumar
    Tang, Y.
    [J]. MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2009, 24 (04): : 207 - 214
  • [6] Direct comparison between the NIST 10 V Compact Josephson Voltage Standard and the 2.5 V Programmable Josephson Voltage Standard
    Shiv Kumar Jaiswal
    Y. Tang
    [J]. MAPAN, 2009, 24 : 207 - 214
  • [7] Direct comparison between the NIST 10 V Conventional Josephson Voltage Standard and 2.5 V Programmable Josephson Voltage Standard
    Shiv Kumar Jaiswal
    [J]. MAPAN, 2011, 26 : 339 - 348
  • [8] 1 volt DC programmable Josephson voltage standard
    Burroughs, CJ
    Benz, SP
    Harvey, TE
    Hamilton, CA
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 4145 - 4149
  • [9] SINIS Josephson junctions for programmable Josephson voltage standard circuits
    Schulze, H
    Müller, F
    Behr, R
    Kohlmann, J
    Niemeyer, J
    Balashov, D
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 4241 - 4244
  • [10] Compact DC Josephson Voltage Standard
    Rufenacht, Alain
    Fox, Anna E.
    Butler, Grace E.
    Burroughs, Charles J.
    Dresselhaus, Paul D.
    Schwall, Robert E.
    Cular, Stefan
    Benz, Samuel P.
    [J]. 2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,