Enhanced effectiveness with positive Joule-Thomson pressure drop effects on a cryogenic heat exchanger with three fluid-two communications

被引:0
|
作者
Chodankar, Vishnudas Alias Vipul Luvu [1 ]
Aswatha [2 ]
Seetharamu, K. N. [3 ]
机构
[1] Saraswati Coll Engn, Dept Automobile Engn, Navimumbai, India
[2] Bangalore Inst Technol, Dept Mech Engn, Bangalore, Karnataka, India
[3] PES Inst Technol, Dept Mech Engn, Bangalore, Karnataka, India
关键词
Finite element methods; Heat exchangers; Numerical study; Cryogenic; Joule-Thomson; Positive pressure loss;
D O I
10.1108/HFF-03-2021-0189
中图分类号
O414.1 [热力学];
学科分类号
摘要
Purpose The purpose of this paper is to attain higher effectiveness with an introduction of Joule-Thomson effect on a three-fluid heat exchanger with two communications. It also gives a range of parameter values that have to be maintained for achieving effectiveness above 0.85. Attaining effectiveness above 0.85 is very important for the heat exchanger to perform the liquefaction of hot fluid. Design/methodology/approach The analysis is conducted using Galerkin's method, a finite element approach. Findings This investigation determines crucial values for the cryogenic heat exchanger to achieve effectiveness above 0.85. The important findings are as follows: effectiveness above 0.85 is attained if the heat exchanger size is within the range of 8-10; ratio of heat flow resistance between intermediate and hot stream to heat flow resistance between cold and hot stream should be maintained between 1 and 10; the intermediate fluid temperature should be maintained between 0 and 0.2; the ratio of thermal capacity of the hot fluid relative to a cold fluid should be maintained between 1.25 and 1.42; and the ratio of thermal capacity of the hot fluid relative to an intermediate fluid should be maintained between 2 and 2.5. Research limitations/implications The investigation has presented a finding for improving the effectiveness of the cryogenic heat exchanger. Higher the Joule-Thomson pressure drop effect, more is the drop in temperature of the fluid resulting in additional cooling or lowering of the fluid temperature. The practical implementation is also explained, i.e. to achieve practically the Joule-Thomson pressure drop in a cryogenic heat exchanger. Originality/value To the best of the authors' knowledge, no investigations were carried out previously on Joule-Thomson investigation on a three-fluid heat exchanger with two communications, for different values of Joule-Thomson pressure drop.
引用
收藏
页码:1778 / 1792
页数:15
相关论文
共 23 条
  • [21] Effect of ambient heat-in-leak on transient behaviour of three-fluid heat exchanger with two thermal communications using finite element method
    Veerabhadrappa, Kavadiki
    Vinayakaraddy
    Seetharamu, K. N.
    Hegde, Pradeep G.
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (09) : 10596 - 10602
  • [22] Numerical study on the influence of flow direction and fluid type on heat transfer and pressure drop in a two-tube spiral heat exchanger with innovative conical turbulators
    Haddadvand, Reza
    Sohrabi, Neaman
    Yan, Terry X.
    Nadalinia, Fatemehh
    Karouei, Seyed Hossein Hashemi
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 81
  • [23] Microchannel size effects on two-phase local heat transfer and pressure drop in silicon microchannel heat sinks with a dielectric fluid
    Harirchian, Tannaz
    Garimella, Suresh V.
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 11 PT A AND PT B: MICRO AND NANO SYSTEMS, 2008, : 437 - 446