A container-based facility for testing 20'000 20-inch PMTs for JUNO

被引:8
|
作者
Wonsak, B. [1 ]
Tietzsch, A. [2 ]
Sterr, T. [2 ]
Lachenmaier, T. [2 ]
Anfimov, N. [3 ]
Blum, D. [2 ]
Hagner, C. [1 ]
Kaiser, B. [1 ,2 ]
Meyhofer, D. [1 ]
Olshevskiy, A. [3 ]
Qin, Z. [4 ]
Rebber, H. [1 ]
Reichert, S. [1 ,5 ]
Stender, M. [1 ]
Wang, W. [6 ,7 ]
Wang, Z. [4 ]
机构
[1] Univ Hamburg, Inst Expt Phys, Luruper Chaussee 149, D-22761 Hamburg, Germany
[2] Eberhard Karls Univ Tubingen, Phys Inst, Morgenstelle 14, D-72076 Tubingen, Germany
[3] Joint Inst Nucl Res, Particle Phys Div, Dzhelepov Lab Nucl Problems, Joliot Curie 6, Dubna 141980, Russia
[4] Inst High Energy Phys, 19B Yuquan Rd, Beijing 100049, Peoples R China
[5] Heidelberg Univ, Med Fac Mannheim, Comp Assisted Clin Med, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
[6] Sun Yat Sen Univ, 135 Xingangxi Rd, Guangzhou 510275, Peoples R China
[7] Sun Yat Sen Univ, Sinofrench Inst Nucl Engn & Technol, 2 Daxue Rd, Zhuhai 519082, Peoples R China
关键词
Neutrino detectors; Photon detectors for UV; visible and IR photons (vacuum); Data acquisition concepts; SYSTEM;
D O I
10.1088/1748-0221/16/08/T08001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The main goal of the JUNO experiment is the determination of the neutrino mass ordering. To achieve this, an extraordinary energy resolution of at least 3 % at 1 MeV is required for which all parts of the JUNO detector need to meet certain quality criteria. This is relevant in particular for those which are related to the energy resolution of the detector, such as the photo-multiplier tubes (PMTs) to be deployed in JUNO. This paper presents the setup and performance of a dedicated PMT mass testing facility to examine and characterize the performance of the 20-inch JUNO PMTs. Its quasi-industrial size and operation level allows to test all 20000 PMTs intended to be used in the JUNO experiment. With this PMT mass testing system, several key characteristics like dark count rate, peak-to-valley ratio, photon detection efficiency, and timing resolution have been determined at an operating gain of 1 x 10(7) and assessed with respect to the requirements of JUNO. Measurement conditions and modes for the PMTs as well as estimated accuracies for the determination of the individual PMT parameters with the system are presented as well.
引用
收藏
页数:22
相关论文
共 50 条
  • [32] UPSCALE DISPLAYS - 20-INCH AND 21-INCH MONITORS
    不详
    BYTE, 1995, 20 (01): : 212 - &
  • [33] Study of TTS for a 20-inch dynode PMT
    廖东豪
    刘宏邦
    周亦雄
    罗凤姣
    王志民
    杨安波
    徐美杭
    谢万
    秦中华
    Chinese Physics C, 2017, (07) : 127 - 132
  • [34] WISCONSIN AMATEURS 20-INCH NEWTONIAN REFLECTOR
    PARMENTI.R
    SKY AND TELESCOPE, 1972, 44 (OCT): : 258 - &
  • [35] Check on the features of potted 20-inch PMTs with 1F3 electronics prototype at Pan-Asia
    Liu, Caimei
    Li, Min
    Wang, Zhimin
    Hu, Jun
    Anfimov, Nikolay
    Fan, Lei
    Garfagnini, Alberto
    Gong, Guanghua
    Hou, Shaojing
    Ji, Xiaolu
    Jiang, Xiaoshan
    Korablev, Denis
    Lachenmaier, Tobias
    Ma, Si
    Ma, Xiaoyan
    Ning, Zhe
    Olshevskiy, Alexander G.
    Peng, Zhaoyuan
    Qin, Zhonghua
    Sterr, Tobias
    Sun, Yunhua
    Tietzsch, Alexander Felix
    Wang, Jun
    Wang, Wei
    Wang, Yangfu
    Wen, Kaile
    Wonsak, Bjoern Soenke
    Xie, Wan
    Xu, Meihang
    Yan, Xiongbo
    Yang, Yifan
    Zhao, Rong
    Zhou, Tong
    Zhu, Kejun
    JOURNAL OF INSTRUMENTATION, 2023, 18 (02)
  • [36] UPSCALE DISPLAYS - 20-INCH AND 21-INCH MONITORS (VOL 20, PG 212, 1995)
    不详
    BYTE, 1995, 20 (03): : 20 - 20
  • [37] Internal inspection of 20-inch natural gas pipeline
    Ostrander, BB
    PIPELINES IN THE CONSTRUCTED ENVIRONMENT, 1998, : 387 - 396
  • [38] Research and development of 20-inch PMT uniformity scanning platform
    Gao, Feng
    Qian, Sen
    Ma, Yichao
    Xia, Jingkai
    Ning, Zhe
    Wang, Zhigang
    Ma, Lishuang
    Wu, Qi
    Peng, Shuo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [39] A 20-INCH FOCAL LENGTH F/1 CATADIOPTRIC OBJECTIVE
    YODER, PR
    SCIDMORE, WH
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1966, 56 (10) : 1417 - &
  • [40] PRELIMINARY INVESTIGATION OF FIELD DISTORTION OF THE 20-INCH CARNEGIE ASTROGRAPH
    VASILEVSKIS, S
    ASTRONOMICAL JOURNAL, 1951, 56 (04): : 107 - 109