Needle detection using ultrasound B-mode and power Doppler analyses

被引:2
|
作者
Daoud, Mohammad I. [1 ]
Abu-Hani, Ayah F. [2 ]
Shtaiyat, Ahmad [1 ]
Ali, Mostafa Z. [3 ]
Alazrai, Rami [1 ]
机构
[1] German Jordanian Univ, Dept Comp Engn, Amman 11180, Jordan
[2] Tech Univ Munich, Dept Elect & Comp Engn, Munich, Germany
[3] Jordan Univ Sci & Technol, Dept Comp Informat Syst, Irbid, Jordan
关键词
B-mode image analysis; Doppler image analysis; needle detection; ultrasound imaging; ultrasound-guided needle interventions; CURVILINEAR ULTRASOUND; TIME; LOCALIZATION; ENHANCEMENT; TRACKING; VISUALIZATION; VISIBILITY; CAMERA;
D O I
10.1002/mp.15725
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Ultrasound is employed in needle interventions to visualize the anatomical structures and track the needle. Nevertheless, needle detection in ultrasound images is a difficult task, specifically at steep insertion angles. Purpose A new method is presented to enable effective needle detection using ultrasound B-mode and power Doppler analyses. Methods A small buzzer is used to excite the needle and an ultrasound system is utilized to acquire B-mode and power Doppler images for the needle. The B-mode and power Doppler images are processed using Radon transform and local-phase analysis to initially detect the axis of the needle. The detection of the needle axis is improved by processing the power Doppler image using alpha shape analysis to define a region of interest (ROI) that contains the needle. Also, a set of feature maps is extracted from the ROI in the B-mode image. The feature maps are processed using a machine learning classifier to construct a likelihood image that visualizes the posterior needle likelihoods of the pixels. Radon transform is applied to the likelihood image to achieve an improved needle axis detection. Additionally, the region in the B-mode image surrounding the needle axis is analyzed to identify the needle tip using a custom-made probabilistic approach. Our method was utilized to detect needles inserted in ex vivo animal tissues at shallow [20 circle-40 circle$20<^>\circ -40<^>\circ$), moderate [40 circle-60 circle$40<^>\circ -60<^>\circ$), and steep [60 circle-85 circle$60<^>\circ -85<^>\circ$] angles. Results Our method detected the needles with failure rates equal to 0% and mean angle, axis, and tip errors less than or equal to 0.7 degrees, 0.6 mm, and 0.7 mm, respectively. Additionally, our method achieved favorable results compared to two recently introduced needle detection methods. Conclusions The results indicate the potential of applying our method to achieve effective needle detection in ultrasound images.
引用
收藏
页码:4999 / 5013
页数:15
相关论文
共 50 条
  • [41] Application of Demons Algorithm in Ultrasound Elastography using B-Mode Ultrasound Images
    Tehrani, Ali Kafaei Zad
    Mozaffarzadeh, Moein
    Mardi, Zahra
    Hozhabr, Seyed Hani
    Mehrmohammadi, Mohammad
    Makkiabadi, Bahador
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2019, 2019, 10878
  • [42] B-mode and Doppler ultrasound imaging of the spleen with canine splenic torsion: A retrospective evaluation
    Saunders, HM
    Neath, PJ
    Brockman, DJ
    VETERINARY RADIOLOGY & ULTRASOUND, 1998, 39 (04) : 349 - 353
  • [43] A Doppler and B-Mode Hybrid Ultrasound Tracking Method for Microcatheter Navigation in Noisy Environments
    Zhang, Moqiu
    Yang, Lidong
    Yang, Haojin
    Su, Lin
    Zhang, Li
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON MANIPULATION, AUTOMATION, AND ROBOTICS AT SMALL SCALES (MARSS 2022), 2022,
  • [44] B-mode Ultrasound Versus Color Doppler Twinkling Artifact in Detecting Kidney Stones
    Sorensen, Mathew D.
    Harper, Jonathan D.
    Hsi, Ryan S.
    Shah, Anup R.
    Dighe, Manjiri K.
    Carter, Stephen J.
    Moshiri, Mariam
    Paun, Marla
    Lu, Wei
    Bailey, Michael R.
    JOURNAL OF ENDOUROLOGY, 2013, 27 (02) : 149 - 153
  • [45] AUTOMATED DETECTION AND MEASUREMENT OF ATHEROSCLEROTIC CAROTID PLAQUES IN B-MODE ULTRASOUND
    Monajemi, S.
    Mohammadzadeh, M.
    Lange, R. F. B.
    Sharma, V. K.
    INTERNATIONAL JOURNAL OF STROKE, 2018, 13 : 207 - 207
  • [46] B-mode and Doppler ultrasound of bitches' kidneys with mammary neoplasia submitted to adjuvant chemotherapy
    da Silva, Ligia O. Pinto
    Santos, Marcia Carolina S.
    Pina, Bianca F.
    Souza, Guilherme N.
    Ferreira, Maria de Lourdes G.
    PESQUISA VETERINARIA BRASILEIRA, 2023, 43
  • [47] Evaluation of common carotid artery changes in Saudi current smokers using medical ultrasound (B-mode and Doppler)
    Khalid S. Alzimami
    Mustafa Z. Mahmoud
    Abdelmoneim Sulieman
    Journal of Medical Ultrasonics, 2014, 41 : 351 - 357
  • [48] Renal evaluation with B-mode and Doppler ultrasound in captive tufted capuchins (Sapajus apella)
    da Silva, Luciana Carandina
    de Vasconcelos Machado, Vania Maria
    Teixeira, Carlos Roberto
    dos Santos, Roberta Valeriano
    Dias Neto, Ramiro das Neves
    Melchert, Alessandra
    Rahal, Sheila Canevese
    JOURNAL OF MEDICAL PRIMATOLOGY, 2016, 45 (01) : 28 - 33
  • [49] Evaluation of the portio vaginalis of the cervix by B-mode and colour Doppler ultrasound in Simmental cattle
    Risvanli, Ali
    Safak, Tarik
    Yilmaz, Oznur
    Yuksel, Burak
    Kilinc, Mehmet Akif
    Seker, Ibrahim
    ACTA VETERINARIA BRNO, 2022, 91 (01) : 3 - +
  • [50] B-mode and Doppler features of struma ovarii
    Royo, P.
    Alcazar, J. L.
    Virgen, M.
    Mazaira, J.
    Jurado, M.
    Lopez, G.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (01) : 109 - 110