Quantitatively characterizing fluctuations of dielectric susceptibility of tissue with Fourier domain optical coherence tomography

被引:11
|
作者
Gao, Wanrong [1 ]
机构
[1] Nanjing Univ Sci & Technol, Dept Opt Engn, Nanjing 210094, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
SCATTERING MEDIA; BACKSCATTERING; ATTENUATION; TECHNOLOGY;
D O I
10.1364/JOSAA.27.002588
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new model of Fourier domain optical coherence tomography (FDOCT) is proposed, valid within the first Born approximation, which takes the fluctuations of the dielectric susceptibility of tissue into account. It is shown that the spectral electrical power at the detector in the FDOCT system is proportional to the Fourier component of the spatial correlation function of the dielectric susceptibility of the tissue, proportional to the squares of the spectrum of the incident light field and the amplitude reflectance of the reference mirror. One possible application of the obtained result is to use the measured spectral data of the spatial correlation function of the dielectric susceptibility to quantitatively characterize properties of tissue. (C) 2010 Optical Society of America
引用
收藏
页码:2588 / 2592
页数:5
相关论文
共 50 条
  • [21] Fourier domain optical coherence tomography with ultralong depth range
    Zhihua DING
    Yi SHEN
    Wen BAO
    Peng LI
    Frontiers of Optoelectronics, 2015, 8 (02) : 163 - 169
  • [22] Dual beam heterodyne Fourier domain optical coherence tomography
    Bachmann, Adrian H.
    Michaely, Roland
    Lasser, Theo
    Leitgeb, Rainer A.
    OPTICS EXPRESS, 2007, 15 (15) : 9254 - 9266
  • [23] Flow Velocity Quantification with Fourier Domain Optical Coherence Tomography
    Walther, Julia
    Mueller, Gregor
    Morawietz, Henning
    Koch, Edmund
    TM-TECHNISCHES MESSEN, 2009, 76 (04) : 198 - 210
  • [24] Mirror image free Fourier domain optical coherence tomography
    Zhang, J
    Nelson, JS
    Chen, ZP
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 : 114 - 120
  • [25] Fourier domain optical coherence tomography with ultralong depth range
    Ding Z.
    Shen Y.
    Bao W.
    Li P.
    Frontiers of Optoelectronics, 2015, 8 (2) : 163 - 169
  • [26] Fourier domain optical coherence tomography system with balance detection
    Bradu, Adrian
    Podoleanu, Adrian Gh.
    OPTICS EXPRESS, 2012, 20 (16): : 17522 - 17538
  • [27] Fourier domain optical coherence tomography for imaging of biological tissues
    Ma, ZH
    Zhu, SQ
    Wang, RK
    Zhang, F
    Yao, JQ
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT II , PTS 1 AND 2, 2005, 5630 : 844 - 850
  • [28] Scattering imaging of skin in Fourier domain optical coherence tomography
    Guo, Xin
    Bu, Peng
    Wang, Xiangzhao
    Sasaki, Osami
    Nan, Nan
    Huang, Bingjie
    Li, Zhongliang
    OPTICS COMMUNICATIONS, 2013, 305 : 137 - 142
  • [29] Resonant Doppler Imaging with Fourier domain optical coherence tomography
    Leitgeb, RA
    Szkulmowska, A
    Pircher, M
    Götzinger, E
    Fercher, AF
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 : 440 - 445
  • [30] Spectrometer calibration for spectroscopic Fourier domain optical coherence tomography
    Szkulmowski, Maciej
    Tamborski, Szymon
    Wojtkowski, Maciej
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (12): : 5042 - 5054