The Impact of Glaucoma Drainage Devices on the Cornea

被引:0
|
作者
Weinlander, Eric [1 ]
Meijome, Tomas [1 ]
Shah, Manjool [1 ]
机构
[1] Univ Michigan, Kellogg Eye Ctr, 1000 Wall St, Ann Arbor, MI 48105 USA
关键词
Glaucoma surgery; Glaucoma drainage device; Endothelium; Keratoplasty; Graft survival; INTRAOCULAR-PRESSURE CONTROL; STRIPPING ENDOTHELIAL KERATOPLASTY; GRAFT-SURVIVAL; PENETRATING KERATOPLASTY; POSTOPERATIVE COMPLICATIONS; VALVE IMPLANTATION; CELL DENSITY; RISK-FACTORS; PARS-PLANA; EYES;
D O I
10.1007/s40135-020-00234-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of ReviewTo discuss the relevant clinical associations between glaucoma drainage device (GDD) implantation and health of the cornea, focusing on corneal endothelial disease and success of viability of keratoplasty.Recent FindingsCorneal endothelial injury and risk of graft failure continues to demonstrate association with GDD placement; however, newer studies demonstrate improved outcomes associated with Descemet membrane endothelial keratoplasty. Additionally, newer adverse effects associated with GDD placement have been described.SummaryGDD implantation certainly carries risk of endothelial injury and keratoplasty viability, but newer keratoplasty techniques may improve visual outcomes. Furthermore, attention to placement and location of the GDD may affect the risk of progressive corneal injury.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 50 条
  • [31] Glaucoma drainage devices in children: an updated review
    Vasconcelos, Alex Teles
    Massote, Jose Aloisio
    Senger, Cassia
    Barbieri, Livia Prudente
    Cronemberger, Sebastiao
    Paula, Jayter Silva
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2024, 87 (06)
  • [32] Simultaneous Implantation of Two Glaucoma Drainage Devices for Uncontrolled Advanced Glaucoma
    Rao, Veena
    Christenbury, Joseph
    Lee, Paul P.
    Herndon, Leon W.
    Challa, Pratap
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [33] Implantation of second glaucoma drainage devices after failure of primary devices
    Godfrey, DG
    Krishna, R
    Greenfield, DS
    Budenz, DL
    Gedde, SJ
    Scott, IU
    OPHTHALMIC SURGERY AND LASERS, 2002, 33 (01): : 37 - 43
  • [34] Strabismus surgery outcomes in eyes with glaucoma drainage devices
    Osigian, Carla J.
    Cavuoto, Kara M.
    Rossetto, Julia D.
    Sayed, Mohamed
    Grace, Sara
    Chang, Ta C.
    Capo, Hilda
    JOURNAL OF AAPOS, 2017, 21 (02): : 103 - 106
  • [35] Location of glaucoma drainage devices (Addendum to previous report)
    Read, RW
    Chen, PP
    Stanford, DC
    Mills, RP
    Reynolds, AC
    OPHTHALMOLOGY, 1998, 105 (11) : 1977 - 1977
  • [36] A Novel Antiproliferative Drug Coating for Glaucoma Drainage Devices
    Ponnusamy, Thiruselvam
    Yu, Haini
    John, Vijay T.
    Ayyala, Ramesh S.
    Blake, Diane A.
    JOURNAL OF GLAUCOMA, 2014, 23 (08) : 526 - 534
  • [37] Glaucoma Drainage Devices: Tube versus Trabeculectomy Study
    Rosentreter, A.
    Strzalkowski, P.
    Bula, A. M.
    Alnawaiseh, M.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2018, 235 (02) : 175 - 179
  • [38] The Use of Nonabsorbable Suture Ligatures for Glaucoma Drainage Devices
    Moura Filho, Edney R.
    Sit, Arthur J.
    ARCHIVES OF OPHTHALMOLOGY, 2010, 128 (05) : 624 - 627
  • [39] Development of an Oculopressor to Evaluate the Efficiency of Glaucoma Drainage Devices
    Kopp, Franziska
    Koschmieder, Anita
    Stahnke, Thomas
    Pfensig, Sylvia
    Specht, Olaf
    Grabow, Niels
    Schmitz, Klaus-Peter
    Guthoff, Rudolf F.
    Siewert, Stefan
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2018, 235 (12) : 1360 - 1365
  • [40] Postoperative Follow-Up of Glaucoma Drainage Devices
    Dietlein, T. S.
    Neugebauer, A.
    Fricke, J.
    Lappas, A.
    Rosentreter, A.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2016, 233 (05) : 606 - 612