Pedicle screw fixation for isthmic spondylolisthesis: does posterior lumbar interbody fusion improve outcome over posterolateral fusion?

被引:64
|
作者
La Rosa, G [1 ]
Conti, A [1 ]
Cacciola, F [1 ]
Cardali, S [1 ]
La Torre, D [1 ]
Gambadauro, NM [1 ]
Tomasello, F [1 ]
机构
[1] Univ Messina, Sch Med, Neurosurg Clin, Messina, Italy
关键词
spondylolisthesis; spinal fusion; pedicle screw; posterior lumbar interbody fusion;
D O I
10.3171/spi.2003.99.2.0143
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object Posterolateral fusion involving instrumentation-assisted segmental fixation represents a valid procedure in the treatment of lumbar instability. In cases of anterior column failure, such as in isthmic spondylolisthesis, supplemental posterior lumbar interbody fusion (PLIF) may improve the fusion rate and endurance of the construct. Posterior lumbar interbody fusion is, however, a more demanding procedure and increases costs and risks of the intervention. The advantages of this technique must, therefore, be weighed against those of a simple posterior lumbar fusion. Methods. Thirty-five consecutive patients underwent pedicle screw fixation for isthmic spondylolisthesis. In 18 patients posterior lumbar fusion was performed, and in 17 patients PLIF was added. Clinical, economic, functional, and radiographic data were assessed to determine differences in clinical and functional results and biomechanical properties. At 2-year follow-up examination, the correction of subluxation, disc height, and foraminal area were maintained in the group in which a PLIF procedure was performed, but not in the posterolateral fusion-only group (p < 0.05). Nevertheless, no statistical intergroup differences were demonstrated in terms of neurological improvement (p = 1), economic (p = 0.43), or functional (p = 0.95) outcome, nor in terms of fusion rate (p = 0.49). Conclusions. The authors' findings support the view that an interbody fusion confers superior mechanical strength to the spinal construct; when posterolateral fusion is the sole intervention, progressive loss of the extreme correction can be expected. Such mechanical insufficiency, however, did not influence clinical outcome.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [21] Comparison between posterior lumbar fusion with pedicle screws and posterior lumbar interbody fusion with pedicle screws in adult spondylolisthesis
    Rolemberg Dantas, Fernando Luiz
    Prandini, Mirto Nelso
    Ferreira, Mauro A. T.
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2007, 65 (3B) : 764 - 770
  • [22] Comparison of posterolateral fusion with and without additional posterior lumbar interbody fusion for degenerative lumbar spondylolisthesis
    Ha, Kee-Yong
    Na, Ki-Ho
    Shin, Jae-Hyuk
    Kim, Ki-Won
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (04): : 229 - 234
  • [23] Comparative Study of Unilateral and Bilateral Pedicle Screw Fixation in Posterior Lumbar Interbody Fusion
    Xie, Youzhuan
    Ma, Hui
    Li, Hua
    Ding, Wei
    Zhao, Changqing
    Zhang, Pu
    Zhao, Jie
    ORTHOPEDICS, 2012, 35 (10) : E1517 - E1523
  • [24] Single segment of posterior lumbar interbody fusion for adult isthmic spondylolisthesis: reduction or fusion in situ
    Lian, Xiao-Feng
    Hou, Tie-Sheng
    Xu, Jian-Guang
    Zeng, Bing-Fang
    Zhao, Jie
    Liu, Xiao-Kang
    Yang, Er-Zhu
    Zhao, Cheng
    EUROPEAN SPINE JOURNAL, 2014, 23 (01) : 172 - 179
  • [25] Posterior lumbar interbody fusion for adult isthmic spondylolisthesis - A comparision of fusion with one or two cages
    Suh, K. T.
    Park, W. W.
    Kim, S-J
    Cho, H. M.
    Lee, J. S.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10): : 1352 - 1356
  • [26] Single segment of posterior lumbar interbody fusion for adult isthmic spondylolisthesis: reduction or fusion in situ
    Xiao-Feng Lian
    Tie-Sheng Hou
    Jian-Guang Xu
    Bing-Fang Zeng
    Jie Zhao
    Xiao-Kang Liu
    Er-Zhu Yang
    Cheng Zhao
    European Spine Journal, 2014, 23 : 172 - 179
  • [27] Subsidence of Metal Interbody Cage After Posterior Lumbar Interbody Fusion With Pedicle Screw Fixation Reply
    Tokuhashi, Yasuaki
    ORTHOPEDICS, 2010, 33 (04) : 227 - 228
  • [28] Respective Correction Rates of Lateral Lumbar Interbody Fusion and Percutaneous Pedicle Screw Fixation for Lumbar Degenerative Spondylolisthesis
    Isogai, Norihiro
    Yoshida, Kodai
    Shiono, Yuta
    Sasao, Yutaka
    Funao, Haruki
    Ishii, Ken
    MEDICINA-LITHUANIA, 2022, 58 (02):
  • [29] Outcome of posterior lumbar interbody fusion versus posterolateral fusion in lumbar degenerative disease
    Wu, Yungang
    Tang, Hao
    Li, Zhonghai
    Zhang, Qiulin
    Shi, Zhicai
    JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (06) : 780 - 783
  • [30] Slippage reduction of lumbar spondylolisthesis using percutaneous pedicle screw with reduction fixation system after interbody fusion: A comparison with traditional open fusion and pedicle screw fixation
    Heo, Dong-Hwa
    Jang, Jae-Won
    Lee, Jung-Kil
    Park, Choon-Keun
    JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 67 : 156 - 162