Assessment of Left Ventricular Volumes and Function by Real Time Three-Dimensional Echocardiography in a Pediatric Population: A TomTec versus QLAB Comparison

被引:34
|
作者
Hascoet, Sebastien [1 ]
Brierre, Gilles [1 ]
Caudron, Guillaume [1 ]
Cardin, Christelle [1 ]
Bongard, Vanina [2 ]
Acar, Philippe [1 ]
机构
[1] Ctr Hosp Univ Toulouse, Dept Paediat Cardiol, Hop Enfants, 330 Ave Grande Bretagne, F-31000 Toulouse, France
[2] Ctr Hosp Univ Toulouse, Dept Epidemiol, UMR INSERM 558, F-31000 Toulouse, France
关键词
real time 3D echocardiography; TomTec; QLAB; left ventricular function; CARDIAC MAGNETIC-RESONANCE; 2-DIMENSIONAL ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; EJECTION FRACTION; BORDER DETECTION; DATA-ACQUISITION; QUANTIFICATION; QUANTITATION; ACCURACY; CHILDREN;
D O I
10.1111/j.1540-8175.2010.01235.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Three-dimensional echocardiography (3DE) allows accurate calculation of ventricular volumes despite a remaining geometric assumption on the ventricular shape. Few studies involving full volume reconstruction software have been performed on children. Our aim was to compare the left ventricular (LV) volume measurements obtained with the most used 3D analysis software in a pediatric population. Methods: Fifty patients (median age: 9.5 years) without cardiac disease were included in the study. 3DE was performed with the X4-2 or X7-2 matrix probe (ie33, Philips). The LV volume analysis was performed with QLAB 6.0 (semiautomated border detection) and TomTec 4D LV (primary manual tracking with semiautomated border detection). Results: TomTec analysis feasibility amounted to 94% whereas QLAB analysis feasibility only reached 80% (P = 0.037). The analysis time was shorter with QLAB than TomTec (5 +/- 2 versus 6 +/- 3 minutes, P < 0.05). The stroke volume, end diastolic and end systolic LV volume measurements performed on the 40 patients were strongly correlated (r > 0.97; P < 0.0001) with minimal bias. The LV ejection fraction was well correlated (r = 0.79; P < 0.0001). Conclusion: 3D LV volume quantification is feasible either by using manual or automated reconstruction software in a normal pediatric population. LV Measurements are well correlated. Differences in volume reconstruction algorithms provide specific software performance characteristics. TomTec is a more feasible method but requires a longer analysis time. Further studies are needed to validate the accuracy of the method to calculate enlarged LV volumes in patients with congenital heart diseases. (Echocardiography 2010;27:1263-1273).
引用
收藏
页码:1263 / 1273
页数:11
相关论文
共 50 条
  • [41] Left ventricular volume estimation for real-time three-dimensional echocardiography
    Corsi, C
    Saracino, G
    Sarti, A
    Lamberti, C
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) : 1202 - 1208
  • [42] Left ventricular ejection fraction by real-time three-dimensional echocardiography
    van Dalen, B. M.
    NETHERLANDS HEART JOURNAL, 2014, 22 (09) : 380 - 382
  • [43] Accuracy and reproducibility of quantitation of left ventricular function by real-time three-dimensional echocardiography versus cardiac magnetic resonance
    Soliman, Osama I. I.
    Kirschbaum, Sharon W.
    van Dalen, Bas M.
    van der Zwaan, Heleen B.
    Delavary, Babak Mahdavian
    Vletter, Wim B.
    van Geuns, Robert-Jan M.
    Ten Cate, Folkert J.
    Geleijnse, Marcel L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (06): : 778 - 783
  • [44] Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: In vitro and in vivo studies
    Qin, JX
    Jones, M
    Shiota, T
    Greenberg, NL
    Tsujino, H
    Firstenberg, MS
    Gupta, PC
    Zetts, AD
    Xu, Y
    Sun, JP
    Cardon, LA
    Odabashian, JA
    Flamm, SD
    White, RD
    Panza, JA
    Thomas, JD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) : 900 - 907
  • [45] AUTOMATED ASSESSMENT OF RIGHT VENTRICULAR VOLUMES AND FUNCTION USING THREE-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    Nillesen, Maartje M.
    van Dijk, Arie P. J.
    Duijnhouwer, Anthonie L.
    Thijssen, Johan M.
    de Korte, Chris L.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (02): : 596 - 606
  • [46] Left ventricular volume and function in cynomolgus monkeys using real-time three-dimensional echocardiography
    Tsusaki, Hideshi
    Yonamine, Haruno
    Tamai, Asako
    Shimomoto, Mutsuko
    Kuwano, Koichi
    Iwao, Hiroshi
    Nagata, Ryoichi
    Kito, Go
    JOURNAL OF MEDICAL PRIMATOLOGY, 2007, 36 (01) : 39 - 46
  • [47] Incremental value of live/real time three-dimensional transthoracic echocardiography in the assessment of left ventricular thrombi
    Duncan, K
    Nanda, NC
    Foster, WAA
    Mehmood, F
    Patel, V
    Singh, A
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (01): : 68 - 72
  • [48] Real-time three-dimensional echocardiography for in-vitro assessment of left ventricular mass in dogs
    Takuma, S
    Cabreriza, SE
    Zwas, DR
    Sciacca, R
    Fard, A
    Chaudhry, H
    Di Tullio, MR
    Spotnitz, H
    Homma, S
    CIRCULATION, 1998, 98 (17) : 701 - 701
  • [49] Can real-time three-dimensional echocardiography be used reliably for the assessment of left ventricular dyssynchrony?
    Agarwal, Richa
    Beshai, John F.
    Lang, Roberto M.
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2009, 102 (6-7) : 469 - 472
  • [50] Assessment of left ventricular function by real-time three-dimensional speckle tracking echocardiography compared to magnetic resonance imaging
    Bremont, C.
    Macron, L.
    Hayat, D.
    Nahum, J.
    Bensaid, A.
    Dubois-Rande, J. L.
    Gueret, P.
    Lim, P.
    EUROPEAN HEART JOURNAL, 2011, 32 : 824 - 825