Scleral Lens Sensor for Ocular Electrolyte Analysis

被引:41
|
作者
Yetisen, Ali K. [1 ]
Jiang, Nan [2 ]
Gonzalez, Carmen M. Castaneda [1 ]
Erenoglu, Zeynep Izlen [1 ]
Dong, Jie [1 ]
Dong, Xingchen [1 ]
Stoesser, Simon [1 ]
Brischwein, Martin [3 ]
Butt, Haider [4 ]
Cordeiro, Maria F. [5 ,6 ,7 ]
Jakobi, Martin [1 ]
Hayden, Oliver [3 ]
Koch, Alexander W. [1 ]
机构
[1] Tech Univ Munich, Inst Measurement Syst & Sensor Technol, D-80290 Munich, Germany
[2] Harvard Univ, Sch Engn & Appl Sci, Cambridge, MA 02138 USA
[3] Tech Univ Munich, Dept Elect & Comp Engn, TranslaTUM Campus, D-80290 Munich, Germany
[4] Khalifa Univ, Dept Mech Engn, Abu Dhabi 127788, U Arab Emirates
[5] Imperial Coll Healthcare NHS Trust, Western Eye Hosp, London NW1 5QH, England
[6] Imperial Coll, ICORG, London NW1 5QH, England
[7] UCL, Inst Ophthalmol, Dept Visual Neurosci, Glaucoma & Retinal Neurodegenerat Grp, London EC1V 9EL, England
关键词
biosensors; diagnostics; ophthalmology; scleral lenses; smartphones; DRY-EYE; TEAR FILM; CONTACT-LENS; LIPID LAYER; FLUORESCENT INDICATORS; CROWN-ETHERS; RISK-FACTORS; SURFACE; CORNEAL; DYSFUNCTION;
D O I
10.1002/adma.201906762
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The quantitative analysis of tear analytes in point-of-care settings can enable early diagnosis of ocular diseases. Here, a fluorescent scleral lens sensor is developed to quantitatively measure physiological levels of pH, Na+, K+, Ca2+, Mg2+, and Zn2+ ions. Benzenedicarboxylic acid, a pH probe, displays a sensitivity of 0.12 pH units within pH 7.0-8.0. Crown ether derivatives exhibit selectivity to Na+ and K+ ions within detection ranges of 0-100 and 0-50 mmol L-1, and selectivities of 15.6 and 8.1 mmol L-1, respectively. A 1,2 bis(o-aminophenoxy)ethane-N,N,-N',N'-tetraacetic-acid-based probe allows Ca2+ ion sensing with 0.02-0.05 mmol L-1 sensitivity within 0.50-1.25 mmol L-1 detection range. 5-Oxazolecarboxylic acid senses Mg2+ ions, exhibiting a sensitivity of 0.10-0.44 mmol L-1 within the range of 0.5-0.8 mmol L-1. The N-(2-methoxyphenyl)iminodiacetate Zn2+ ion sensor has a sensitivity of 1 mu mol L-1 within the range of 10-20 mu mol L-1. The fluorescent sensors are subsequently multiplexed in the concavities of an engraved scleral lens. A handheld ophthalmic readout device comprising light-emitting diodes (LEDs) and bandpass filters is fabricated to excite as well as read the scleral sensor. A smartphone camera application and an user interface are developed to deliver quantitative measurements with data deconvolution. The ophthalmic system enables the assessment of dry eye severity stages and the differentiation of its subtypes.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Quantitative Analysis of Ocular Structure after Scleral Buckle Encircling
    Kim, Yeongjin
    Na, Youngjin
    Kim, Jung
    Seo, Jongmo
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 267 - +
  • [32] Assessment of the Prosthetic Replacement of Ocular Surface Ecosystem (PROSE) scleral lens on visual acuity for corneal irregularity and ocular surface disease
    Parra, Andres S.
    Roth, Bryan M.
    Nguyen, Taylor M.
    Wang, Li
    Pflugfelder, Stephen C.
    Al-Mohtaseb, Zaina
    OCULAR SURFACE, 2018, 16 (02): : 254 - 258
  • [33] Prosthetic Replacement of the Ocular Surface Ecosystem Scleral Lens Therapy for Patients With Ocular Symptoms of Chronic Stevens-Johnson Syndrome
    Heur, Martin
    Bach, Dianne
    Theophanous, Christos
    Chiu, Gloria B.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (01) : 49 - 54
  • [34] Scleral Lens and Prosthetic Replacement of the Ocular Surface Ecosystem Utilization in Ocular Graft-versus-Host Disease: A Survey Study
    Bligdon, Shannon M.
    Colarusso, Bradley A.
    Ganjei, Allen Y.
    Kwok, Alan
    Luo, Zhonghui Katie
    Brocks, Daniel
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 4829 - 4838
  • [35] The influence of limbal and scleral shape on scleral lens design
    Fadel, Daddi
    CONTACT LENS & ANTERIOR EYE, 2018, 41 (04): : 321 - 328
  • [36] A Novel Sutureless Scleral-Fixated Lens That Eliminates Extra Ocular Haptic Manipulation: The CM-T Flex Lens
    Madanagopalan, V. G.
    Madhivanan, Nivean
    Selvam, V. Panneer
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2020, 51 (11): : 648 - 650
  • [37] Ocular burn and scleral lenses
    Laballe, R.
    Merle, H.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2015, 38 (04): : E59 - E60
  • [38] Ultrasound Biomicroscopic Analysis of the Sutureless Scleral Fixated Intraocular Lens
    Plemel, David J. A.
    Lapere, Steven
    Rayat, Jaspreet
    Bong, Donna
    Breum, Deana
    Somani, Rizwan
    OPHTHALMOLOGY RETINA, 2018, 2 (12): : 1251 - 1252
  • [39] Complications of Scleral Lens Wear
    Schornack, Muriel
    Harthan, Jennifer
    Barr, Joseph T.
    Shorter, Ellen
    Nau, Amy
    Nau, Cherie B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [40] Persistence of Scleral Lens Wear
    Schornack, Muriel
    Nau, Cherie B.
    Kawulok, Eric
    Tran, Long
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)