Dose conversion coefficients for CT examinations of adults with automatic tube current modulation

被引:32
|
作者
Schlattl, H. [1 ]
Zankl, M. [1 ]
Becker, J. [1 ]
Hoeschen, C. [1 ]
机构
[1] Helmholtz Zentrum Munchen, Natl Res Ctr Environm Hlth, Dept Med Radiat Phys & Diagnost, D-85764 Oberschleissheim, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 20期
关键词
AXIAL SCANNING TOMOGRAPHY; RADIATION-EXPOSURE; VOXEL MODELS; REDUCTION; FEMALE;
D O I
10.1088/0031-9155/55/20/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Automatic tube current modulation (TCM) is used in modern CT devices. This is implemented in the numerical calculation of dose conversion coefficients for CT examinations. For four models of adults, the female and male reference models of ICRP and ICRU and a lighter and a heavier female model, dose conversion coefficients normalized to CTDIvol (DCCCT) have been computed with a Monte Carlo transport code for CT scans with and without TCM. It could be shown for both cases that reliable values for spiral CT scans are obtained when combining the results from an appropriate set of axial scans. The largest organ DCCCT are presented for typical CT examinations for all four models. The impact of TCM is greatest for chest, pelvis and whole-trunk CT examinations, where with TCM the effective DCCCT can be 20-25% lower than without TCM. Typical organs with strong dependence on TCM are thyroid, urinary bladder, lungs and oesophagus. While the DCCCT of thyroid and urinary bladder are mainly sensitive to angular TCM, the DCCCT of lungs and oesophagus are influenced primarily by longitudinal TCM. The impact of the body stature on the effective DCCCT is of the same order as the effect of TCM. Thus, for CT scans in the trunk region, accurate dose values can only be obtained when different sets of DCCCT are employed that are appropriate for the patient's sex and stature and the actual TCM settings.
引用
收藏
页码:6243 / 6261
页数:19
相关论文
共 50 条
  • [1] Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation
    Schlattl, H.
    Zankl, M.
    Becker, J.
    Hoeschen, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (20): : 6309 - 6326
  • [2] Dose reduction in body CT examinations by anatomically adapted tube current modulation
    Bautz, WA
    Heim, I
    Wolf, H
    Kalender, WA
    RADIOLOGY, 1997, 205 : 1399 - 1399
  • [3] Dose reduction in CT examinations of children by anatomically adapted tube current modulation
    Greess, H
    Noemayr, A
    Wolf, H
    Janka, R
    Kalender, WA
    Bautz, WA
    RADIOLOGY, 1999, 213P : 294 - 294
  • [4] Influence of CT automatic tube current modulation on uncertainty in effective dose
    Sookpeng, S.
    Martin, C. J.
    Gentle, D. J.
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (01) : 46 - 54
  • [5] Organ dose conversion coefficients for tube current modulated CT protocols for an adult population
    Fu, Wanyi
    Tian, Xiaoyu
    Sahbaee, Pooyan
    Zhang, Yakun
    Segars, William Paul
    Samei, Ehsan
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [6] Real-Time Dose Measurements of Automatic Tube Current Modulation in Multislice CT
    Tsai, H. Y.
    Chang, Y. C.
    Tyan, Y. S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [7] Angular on-line tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reduction
    Papadakis, Antonios E.
    Perisinakis, Kostas
    Damilakis, John
    MEDICAL PHYSICS, 2007, 34 (07) : 2864 - 2874
  • [8] Techniques and applications of automatic tube current modulation for CT
    Kalra, MK
    Maher, MM
    Toth, TL
    Schmidt, B
    Westerman, BL
    Morgan, HT
    Saini, S
    RADIOLOGY, 2004, 233 (03) : 649 - 657
  • [9] ORGAN DOSE EVALUATIONS BASED ON MONTE CARLO SIMULATION FOR CT EXAMINATIONS USING TUBE CURRENT MODULATION
    Fujii, K.
    Nomura, K.
    Muramatsu, Y.
    Obara, S.
    Akahane, K.
    Kusumoto, M.
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (03) : 387 - 394
  • [10] Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation